Electrochemical Study on Inhibitors of Rebar Corrosion in Carbonated Concrete

Electrochemical Impedance Spectroscopy (EIS) was used to evaluate the inhibitive action of some organic compounds towards the corrosion of a carbon steel, both in a solution simulating the pore chemistry of carbonated concrete and in carbonated concrete. The synthetic solution (SS) has been made by bubbling pure CO2 in a saturated Ca(OH)2 solution till obtaining pH 7 and then filtering it. Concrete carbonation has been obtained by maintaining the concrete specimens in CO2 atmosphere for 80 days, at 68% RH and room temperature. In SS, benzoate, its amino-derivatives and dicarboxylates were able to form a long-lasting passive layer on the steel surface. Their efficiency improved with time. In carbonated concrete the additives inducing a decrease in the concrete compressive strength were discarded. Some compounds were monitored for up to 400 days, but only two (the sodium salts of benzoic acid and, particularly, 2-amino benzoic acid) exhibited some inhibitive effect towards the rebar corrosion process.

[1]  J. Beaudoin,et al.  APPLICATION OF A.C. IMPEDANCE TECHNIQUES IN STUDIES OF POROUS CEMENTITIOUS MATERIALS (II): RELATIONSHIP BETWEEN ACIS BEHAVIOR AND THE POROUS MICROSTRUCTURE , 1993 .

[2]  B. Tribollet,et al.  Corrosion mechanisms of steel concrete moulds in the presence of a demoulding agent , 2002 .

[3]  Carmen Andrade,et al.  Passivation of Reinforcing Steel in Concrete , 1995 .

[4]  C. Page Mechanism of corrosion protection in reinforced concrete marine structures , 1975, Nature.

[5]  M. Vazquez,et al.  The performance of a migrating corrosion inhibitor suitable for reinforced concrete , 2003 .

[6]  C. Monticelli,et al.  Corrosion inhibition of steel in chloride-containing alkaline solutions , 2002 .

[7]  M. Pech-Canul,et al.  Corrosion measurements of steel reinforcement in concrete exposed to a tropical marine atmosphere , 2002 .

[8]  Carmen Andrade,et al.  Advances in Electrochemical Impedance Measurements in Reinforced Concrete , 1995 .

[9]  C. Monticelli,et al.  A study on corrosion inhibitors for concrete application , 2000 .

[10]  William John McCarter,et al.  The A.C. response of hardened cement paste , 1990 .

[11]  C. L. Page,et al.  Investigations of reinforcement corrosion. 2. Electrochemical monitoring of steel in chloride-contaminated concrete , 1991 .

[12]  T. Mason,et al.  Assignment of features in impedance spectra of the cement-paste/steel system , 1998 .

[13]  P. Searson,et al.  Use of AC Impedance Technique in Studies on Steel in Concrete in Immersed Conditions , 1981 .

[14]  C. Andrade,et al.  Cement paste hardening process studied by impedance spectroscopy , 1999 .

[15]  C. Andrade,et al.  Impedance measurements on cement paste , 1997 .

[16]  Cruz Alonso,et al.  Study of the Dielectric Characteristics of Cement Paste , 1998 .