Flexible unbalanced control with peak current limitation for virtual synchronous generator under voltage sags

Virtual synchronous generator (VSG) is grid-friendly for integrating distributed generations (DGs) since it can emulate the operation mechanism of traditional synchronous generator (SG). However, the traditional VSG control strategy, which is mainly suitable for balanced voltage conditions, may lead to power oscillations, current unbalance and even overcurrent under unbalanced voltage sags. To overcome this difficulty, a flexible unbalanced control with peak current limitation for VSG under unbalanced operating conditions is proposed. Based on the basic VSG control algorithm, the control strategy integrates two novel control modules, which are current reference generator (CRG) and power reference generator (PRG). The proposed control strategy can flexibly meet different operation demands, which includes current balancing, constant active or reactive power. And the injected currents are kept within safety values for a better utilization of the VSG power capacity. Furthermore, the experimental platform is built. Experimental results demonstrate the validness and effectiveness of the proposed control strategy.

[1]  Yasser Abdel-Rady I. Mohamed,et al.  A Flexible Control Strategy for Grid-Connected and Islanded Microgrids With Enhanced Stability Using Nonlinear Microgrid Stabilizer , 2012, IEEE Transactions on Smart Grid.

[2]  Jon Are Suul,et al.  Small-signal modeling and parametric sensitivity of a virtual synchronous machine in islanded operation , 2015 .

[3]  Luis F. Ochoa,et al.  State-of-the-Art Techniques and Challenges Ahead for Distributed Generation Planning and Optimization , 2013, IEEE Transactions on Power Systems.

[4]  Wanxing Sheng,et al.  Self-Synchronized Synchronverters: Inverters Without a Dedicated Synchronization Unit , 2014, IEEE Transactions on Power Electronics.

[5]  Jiabing Hu,et al.  Sliding-mode-based direct power control of grid-connected voltage-sourced inverters under unbalanced network conditions , 2011 .

[6]  M.R. Iravani,et al.  A Control Strategy for a Distributed Generation Unit in Grid-Connected and Autonomous Modes of Operation , 2008, IEEE Transactions on Power Delivery.

[7]  Zheng Tianwe,et al.  Review and Prospect of Virtual Synchronous Generator Technologies , 2015 .

[8]  Luis García de Vicuña,et al.  Active and Reactive Power Strategies With Peak Current Limitation for Distributed Generation Inverters During Unbalanced Grid Faults , 2015, IEEE Transactions on Industrial Electronics.

[9]  Shengwei Mei,et al.  An integrated control and protection system for photovoltaic microgrids , 2015 .

[10]  Hiroaki Kakigano,et al.  Control of Uninterrupted Switching Using a Virtual Synchronous Generator Between Stand‐Alone and Grid‐Connected Operation of a Distributed Generation System for Houses , 2015 .

[11]  Yasser Abdel-Rady I. Mohamed,et al.  Novel Comprehensive Control Framework for Incorporating VSCs to Smart Power Grids Using Bidirectional Synchronous-VSC , 2014, IEEE Transactions on Power Systems.

[12]  Zhao XU,et al.  Recent advancements on the development of microgrids , 2014 .

[13]  Juan C. Vasquez,et al.  Flexible Voltage Support Control for Three-Phase Distributed Generation Inverters Under Grid Fault , 2013, IEEE Transactions on Industrial Electronics.

[14]  T. Ise,et al.  Stabilization of a power system with a distributed generator by a Virtual Synchronous Generator function , 2011, 8th International Conference on Power Electronics - ECCE Asia.

[15]  Sasa Z. Djokic Recommended Practice for Voltage Sag and Short Interruption Ride-through Testing for End Use Electrical Equipment Rated Less than 1,000 Volts , 2012 .

[16]  Frede Blaabjerg,et al.  Flexible Active Power Control of Distributed Power Generation Systems During Grid Faults , 2007, IEEE Transactions on Industrial Electronics.

[17]  D. G. Holmes,et al.  Control of distributed generation systems under unbalanced voltage conditions , 2014, 2014 International Power Electronics Conference (IPEC-Hiroshima 2014 - ECCE ASIA).

[18]  Qing-Chang Zhong,et al.  Synchronverters: Inverters That Mimic Synchronous Generators , 2011, IEEE Transactions on Industrial Electronics.

[19]  Tianwen Zheng,et al.  Control strategy for suppressing power oscillation of virtual synchronous generator under unbalanced grid voltage , 2015 .

[20]  Yonghua Song,et al.  A Comprehensive Review on the Development of Sustainable Energy Strategy and Implementation in China , 2010, IEEE Transactions on Sustainable Energy.

[21]  Josep M. Guerrero,et al.  Flexible Control Strategy for Grid-Connected Inverter Under Unbalanced Grid Faults Without PLL , 2015, IEEE Transactions on Power Electronics.

[22]  M Castilla,et al.  Grid-Fault Control Scheme for Three-Phase Photovoltaic Inverters With Adjustable Power Quality Characteristics , 2010, IEEE Transactions on Power Electronics.

[23]  H.-P. Beck,et al.  Virtual synchronous machine , 2007, 2007 9th International Conference on Electrical Power Quality and Utilisation.

[24]  Su Jianhui,et al.  Control Strategies of Inverters Based on Virtual Synchronous Generator in a Microgrid , 2009 .

[25]  J. Miret,et al.  Control Scheme for Photovoltaic Three-Phase Inverters to Minimize Peak Currents During Unbalanced Grid-Voltage Sags , 2012, IEEE Transactions on Power Electronics.