The learning curve associated with the introduction of the subcutaneous implantable defibrillator

Abstract Aims The subcutaneous implantable cardioverter defibrillator (S-ICD) was introduced to overcome complications related to transvenous leads. Adoption of the S-ICD requires implanters to learn a new implantation technique. The aim of this study was to assess the learning curve for S-ICD implanters with respect to implant-related complications, procedure time, and inappropriate shocks (IASs). Methods and results In a pooled cohort from two clinical S-ICD databases, the IDE Trial and the EFFORTLESS Registry, complications, IASs at 180 days follow-up and implant procedure duration were assessed. Patients were grouped in quartiles based on experience of the implanter and Kaplan–Meier estimates of complication and IAS rates were calculated. A total of 882 patients implanted in 61 centres by 107 implanters with a median of 4 implants (IQR 1,8) were analysed. There were a total of 59 patients with complications and 48 patients with IAS. The complication rate decreased significantly from 9.8% in Quartile 1 (least experience) to 5.4% in Quartile 4 (most experience) (P = 0.02) and non-significantly for IAS from 7.9 to 4.8% (P = 0.10). Multivariable analysis demonstrated a hazard ratio of 0.78 (P = 0.045) for complications and 1.01 (P = 0.958) for IAS. Dual-zone programming increased with experience of the individual implanter (P < 0.001), which reduced IAS significantly in the multivariable model (HR 0.44, P = 0.01). Procedure time decreased from 75 to 65 min (P < 0.001). The complication rate and procedure time stabilized after Quartile 2 (>13 implants). Conclusion There is a short and significant learning curve associated with physicians adopting the S-ICD. Performance stabilizes after 13 implants.

[1]  Eugene Crystal,et al.  Predictors of Short-Term Complications After Implantable Cardioverter-Defibrillator Replacement: Results From the Ontario ICD Database , 2011, Circulation. Arrhythmia and electrophysiology.

[2]  L. Jordaens,et al.  The entirely subcutaneous implantable cardioverter-defibrillator: initial clinical experience in a large Dutch cohort. , 2012, Journal of the American College of Cardiology.

[3]  D. Wennberg,et al.  The relation between patients' outcomes and the volume of cardioverter-defibrillator implantation procedures performed by physicians treating Medicare beneficiaries. , 2005, Journal of the American College of Cardiology.

[4]  Pier D. Lambiase,et al.  Safety and Efficacy of the Totally Subcutaneous Implantable Defibrillator: 2-Year Results From a Pooled Analysis of the IDE Study and EFFORTLESS Registry. , 2015, Journal of the American College of Cardiology.

[5]  P. Lambiase,et al.  Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD Registry , 2014, European heart journal.

[6]  H. Krumholz,et al.  Association of physician certification and outcomes among patients receiving an implantable cardioverter-defibrillator. , 2009, JAMA.

[7]  W. Lewis,et al.  Learning curves in surgical practice , 2007, Postgraduate Medical Journal.

[8]  Wojciech Zareba,et al.  Cardiac-resynchronization therapy for the prevention of heart-failure events. , 2009, The New England journal of medicine.

[9]  M. Gold,et al.  A New Algorithm to Reduce Inappropriate Therapy in the S‐ICD System , 2015, Journal of cardiovascular electrophysiology.

[10]  A. Wilde,et al.  Two-incision technique for implantation of the subcutaneous implantable cardioverter-defibrillator. , 2013, Heart rhythm.

[11]  C. Valzania,et al.  Current use of implantable electrical devices in Sweden: data from the Swedish pacemaker and implantable cardioverter-defibrillator registry. , 2015, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[12]  Ellen Aagaard Nohr,et al.  Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark , 2013, European heart journal.

[13]  M. Gold,et al.  Head‐To‐Head Comparison of Arrhythmia Discrimination Performance of Subcutaneous and Transvenous ICD Arrhythmia Detection Algorithms: The START Study , 2012, Journal of cardiovascular electrophysiology.

[14]  Alexander H Maass,et al.  An entirely subcutaneous implantable cardioverter-defibrillator. , 2010, The New England journal of medicine.

[15]  Mark Kremers,et al.  Safety and Efficacy of a Totally Subcutaneous Implantable-Cardioverter Defibrillator , 2013, Circulation.

[16]  Arthur A M Wilde,et al.  Inappropriate shocks in the subcutaneous ICD: Incidence, predictors and management. , 2015, International journal of cardiology.

[17]  A. Wilde,et al.  Inappropriate subcutaneous implantable cardioverter-defibrillator shocks due to T-wave oversensing can be prevented: implications for management. , 2014, Heart rhythm.