Wireless distributed functional electrical stimulation system

BackgroundThe control of movement in humans is hierarchical and distributed and uses feedback. An assistive system could be best integrated into the therapy of a human with a central nervous system lesion if the system is controlled in a similar manner. Here, we present a novel wireless architecture and routing protocol for a distributed functional electrical stimulation system that enables control of movement.MethodsThe new system comprises a set of miniature battery-powered devices with stimulating and sensing functionality mounted on the body of the subject. The devices communicate wirelessly with one coordinator device, which is connected to a host computer. The control algorithm runs on the computer in open- or closed-loop form. A prototype of the system was designed using commercial, off-the-shelf components. The propagation characteristics of electromagnetic waves and the distributed nature of the system were considered during the development of a two-hop routing protocol, which was implemented in the prototype’s software.ResultsThe outcomes of this research include a novel system architecture and routing protocol and a functional prototype based on commercial, off-the-shelf components. A proof-of-concept study was performed on a hemiplegic subject with paresis of the right arm. The subject was tasked with generating a fully functional palmar grasp (closing of the fingers). One node was used to provide this movement, while a second node controlled the activation of extensor muscles to eliminate undesired wrist flexion. The system was tested with the open- and closed-loop control algorithms.ConclusionsThe system fulfilled technical and application requirements. The novel communication protocol enabled reliable real-time use of the system in both closed- and open-loop forms. The testing on a patient showed that the multi-node system could operate effectively to generate functional movement.

[1]  A. Kralj,et al.  Functional Electrical Stimulation: Standing and Walking after Spinal Cord Injury , 1989 .

[2]  David Guiraud,et al.  A distributed architecture for activating the peripheral nervous system , 2009, Journal of neural engineering.

[3]  M. Popovic,et al.  Electrical stimulation as a means for achieving recovery of function in stroke patients. , 2009, NeuroRehabilitation.

[4]  G E Loeb,et al.  BION system for distributed neural prosthetic interfaces. , 2001, Medical engineering & physics.

[5]  James Wolfe,et al.  A Biomedical Implantable FES Battery-Powered Micro-Stimulator , 2009, IEEE Transactions on Circuits and Systems I: Regular Papers.

[6]  Thomas Sinkjær,et al.  Clinical Evaluation of Functional Electrical Therapy (FET) in Chronic Hemiplegic Subjects , 2004 .

[7]  Guang-Zhong Yang,et al.  Real-Time Pervasive Monitoring for Postoperative Care , 2007, BSN.

[8]  P. R. Troyk,et al.  DEVELOPMENT OF BION TECHNOLOGY FOR FUNCTIONAL ELECTRICAL STIMULATION : BIDIRECTIONAL TELEMETRY , 2001 .

[9]  G. Troster,et al.  UWB for noninvasive wireless body area networks: channel measurements and results , 2003, IEEE Conference on Ultra Wideband Systems and Technologies, 2003.

[10]  Guang-Zhong Yang,et al.  Body Sensor Networks for Sport, Wellbeing and Health , 2010 .

[11]  Shuenn-Yuh Lee,et al.  An implantable wireless bidirectional communication microstimulator for neuromuscular stimulation , 2005, IEEE Transactions on Circuits and Systems I: Regular Papers.

[12]  Aleksandar Milenkovic,et al.  Journal of Neuroengineering and Rehabilitation Open Access a Wireless Body Area Network of Intelligent Motion Sensors for Computer Assisted Physical Rehabilitation , 2005 .

[13]  Adrian S. Poulton,et al.  A simple to program but sophisticated distributed control system for surface FES applications , 2004 .

[14]  Thomas Sinkjær,et al.  Functional Electrical Therapy (FET): Clinical Trial in Chronic Hemiplegic Subjects , 2004, Neuromodulation : journal of the International Neuromodulation Society.

[15]  T. Sinkjaer,et al.  Clinical evaluation of Functional Electrical Therapy in acute hemiplegic subjects. , 2003, Journal of rehabilitation research and development.

[16]  Allan C Skanes,et al.  Insertable Loop Recorder Use for Detection of Intermittent Arrhythmias , 2004, Pacing and clinical electrophysiology : PACE.

[17]  Eduardo Morgado,et al.  End-to-End Average BER in Multihop Wireless Networks over Fading Channels , 2010, IEEE Transactions on Wireless Communications.

[18]  A. Alonso,et al.  Continuous mobile services for healthcare (HealthService24 project) , 2005 .

[19]  Thomas Sinkjær,et al.  Cortical excitability changes following grasping exercise augmented with electrical stimulation , 2008, Experimental Brain Research.

[20]  G.E. Loeb,et al.  RF-powered BIONs/spl trade/ for stimulation and sensing , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[21]  Philippe Fraisse,et al.  Wireless Distributed Architecture for Therapeutic Functional Electrical Stimulation: a technology to design network-based muscle control , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[22]  M. Ghovanloo,et al.  A Wideband Wireless Neural Stimulation Platform for High-Density Microelectrode Arrays , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[23]  Hang Su,et al.  Battery-dynamics driven tdma mac protocols for wireless body-area monitoring networks in healthcare applications , 2009, IEEE Journal on Selected Areas in Communications.

[24]  Shuenn-Yuh Lee,et al.  Wireless Front-End With Power Management for an Implantable Cardiac Microstimulator , 2012, IEEE Transactions on Biomedical Circuits and Systems.

[25]  M. Popovic,et al.  Sensor-driven four-channel stimulation of paretic leg: Functional electrical walking therapy , 2009, Journal of Neuroscience Methods.

[26]  Liberson Wt,et al.  Functional electrotherapy: stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients. , 1961, Archives of physical medicine and rehabilitation.

[27]  P. Levis,et al.  RSSI is Under Appreciated , 2006 .

[28]  G E Loeb,et al.  RF-powered BIONs for stimulation and sensing. , 2004, Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference.

[29]  Dejan B. Popovic,et al.  New generation of assistive systems for humans with disability: New tool for neurorehabilitation , 2011, 2011 10th International Conference on Telecommunication in Modern Satellite Cable and Broadcasting Services (TELSIKS).

[30]  Patrick Boissy,et al.  Accelerometer-based wireless body area network to estimate intensity of therapy in post-acute rehabilitation , 2008, Journal of NeuroEngineering and Rehabilitation.

[31]  Kin K. Leung,et al.  MAC Essentials for Wireless Sensor Networks , 2010, IEEE Communications Surveys & Tutorials.

[32]  Gerald E. Loeb,et al.  Development of BION/spl trade/ technology for functional electrical stimulation: bidirectional telemetry , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[33]  Dejan B. Popovic,et al.  Sensors driven functional electrical stimulation for restoration of walking in acute stroke patients , 2009 .

[34]  Danail Stoyanov,et al.  Ambient and Wearable Sensor Fusion for Activity Recognition in Healthcare Monitoring Systems , 2007, BSN.

[35]  James Wolfe,et al.  A Biomedical Implantable FES Battery-Powered Micro-Stimulator , 2009, IEEE Trans. Circuits Syst. I Regul. Pap..