Maximizing fluorescence collection efficiency in multiphoton microscopy

Understanding fluorescence propagation through a multiphoton microscope is of critical importance in designing high performance systems capable of deep tissue imaging. Optical models of a scattering tissue sample and the Olympus 20X 0.95NA microscope objective were used to simulate fluorescence propagation as a function of imaging depth for physiologically relevant scattering parameters. The spatio-angular distribution of fluorescence at the objective back aperture derived from these simulations was used to design a simple, maximally efficient post-objective fluorescence collection system. Monte Carlo simulations corroborated by data from experimental tissue phantoms demonstrate collection efficiency improvements of 50% – 90% over conventional, non-optimized fluorescence collection geometries at large imaging depths. Imaging performance was verified by imaging layer V neurons in mouse cortex to a depth of 850 μm.

[1]  Christophe Odin,et al.  Spatially distributed two-photon excitation fluorescence in scattering media: Experiments and time-resolved Monte Carlo simulations , 2007 .

[2]  W. Webb,et al.  Nonlinear magic: multiphoton microscopy in the biosciences , 2003, Nature Biotechnology.

[3]  N. Nishimura,et al.  Deep tissue multiphoton microscopy using longer wavelength excitation. , 2009, Optics express.

[4]  Jerome Mertz,et al.  Two-photon microscopy in brain tissue: parameters influencing the imaging depth , 2001, Journal of Neuroscience Methods.

[5]  Christophe Odin,et al.  Out-of-focus fluorescence collection in two-photon microscopy of scattering media , 2008 .

[6]  Christophe Odin,et al.  Non-descanned versus descanned epifluorescence collection in two-photon microscopy: Experiments and Monte Carlo simulations , 2008 .

[7]  W. Denk,et al.  Two-photon imaging to a depth of 1000 microm in living brains by use of a Ti:Al2O3 regenerative amplifier. , 2003, Optics letters.

[8]  Jerome Mertz,et al.  Epifluorescence collection in two-photon microscopy. , 2002, Applied optics.

[9]  W. Webb,et al.  Measurement of two-photon excitation cross sections of molecular fluorophores with data from 690 to 1050 nm , 1996 .

[10]  Jerome Mertz,et al.  Ultra-deep two-photon fluorescence excitation in turbid media , 2001 .

[11]  W. Denk,et al.  Two-photon laser scanning fluorescence microscopy. , 1990, Science.

[12]  M. Levene,et al.  Multiphoton microscopy of cleared mouse organs. , 2010, Journal of biomedical optics.

[13]  Winfried Denk,et al.  On the fundamental imaging-depth limit in two-photon microscopy , 2006 .