Cross-strip readouts for photon counting detectors with high spatial and temporal resolution

The combination of a photocathode, microchannel plate stack and photon counting, imaging readout provides a powerful tool for high dynamic range, high spatial resolution, and high timing accuracy detectors for the X-ray to visible light spectral range. Significant improvements in spatial resolution, quantum efficiency, and background rate have made these devices attractive for many applications and are being applied to completely new research areas. We describe the latest developments in high-resolution cross-strip (XS) anode readout for photon counting imaging with microchannel plates (MCPs). We show that the spatial resolution of an MCP detector with the cross-strip readout is now limited only by the MCP pore width. For the first time, we show images of resolution test masks illustrating the exceptional spatial resolution of the cross-strip readout, which at the present time can resolve features on the scale of /spl sim/7 /spl mu/m with MCP gains as low as 6/spl times/10/sup 5/. Low-gain operation of the detector with high spatial resolution shown in this paper is very beneficial for applications with high local counting rate and long lifetime requirements. The spatial resolution of the XS anode can be increased even further with improved anode uniformity, lower noise front-end electronics, and new centroiding algorithms. This could be important when MCPs with smaller than existing 6 /spl mu/m pores become commercially available, thus improving the detector resolution down to the few micrometer scale.

[1]  A. Tremsin,et al.  Spatial distribution of electron cloud footprints from microchannel plates: Measurements and modeling , 1999 .

[2]  John V. Vallerga,et al.  The latest developments of high-gain Si microchannel plates , 2003, SPIE Astronomical Telescopes + Instrumentation.

[3]  T. A. Lewis,et al.  A fast and accurate position-sensitive timing detector based on secondary electron emission , 2000 .

[4]  Oswald H. W. Siegmund,et al.  Charge cloud asymmetry in detectors with biased MCPs , 2002, SPIE Optics + Photonics.

[5]  R. Dinapoli,et al.  Medipix2: A 64-k pixel readout chip with 55-/spl mu/m square elements working in single photon counting mode , 2001 .

[6]  Melville P. Ulmer,et al.  Efficient GaN photocathodes for low-level ultraviolet signal detection , 2002 .

[7]  O. Siegmund,et al.  Fast microchannel plate detector with an impedance matched anode in suspended substrate technology , 2001 .

[8]  Charles P. Beetz,et al.  Silicon-micromachined microchannel plates , 2000 .

[9]  L. Blanquart,et al.  A pixel detector with large dynamic range for high photon counting rates , 2002 .

[10]  R. Abiad,et al.  High resolution cross strip anodes for photon counting detectors , 2003 .

[11]  Anton S. Tremsin,et al.  Quantum efficiency and stability of alkali halide UV photocathodes in the presence of electric field , 2003 .

[12]  J. V. Vallerga,et al.  Cross strip imaging anodes for microchannel plate detectors , 2001 .

[13]  Charles P. Beetz,et al.  Si microchannel plates for image intensification , 2000, SPIE Optics + Photonics.

[14]  Oswald H. W. Siegmund,et al.  Centroiding algorithms and spatial resolution of photon counting detectors with cross-strip anodes , 2003, SPIE Optics + Photonics.