VTrails: Inferring Vessels with Geodesic Connectivity Trees

The analysis of vessel morphology and connectivity has an impact on a number of cardiovascular and neurovascular applications by providing patient-specific high-level quantitative features such as spatial location, direction and scale. In this paper we present an end-to-end approach to extract an acyclic vascular tree from angiographic data by solving a connectivity-enforcing anisotropic fast marching over a voxel-wise tensor field representing the orientation of the underlying vascular tree. The method is validated using synthetic and real vascular images. We compare VTrails against classical and state-of-the-art ridge detectors for tubular structures by assessing the connectedness of the vesselness map and inspecting the synthesized tensor field as proof of concept. VTrails performance is evaluated on images with different levels of degradation: we verify that the extracted vascular network is an acyclic graph (i.e. a tree), and we report the extraction accuracy, precision and recall.

[1]  Alejandro F. Frangi,et al.  Muliscale Vessel Enhancement Filtering , 1998, MICCAI.

[2]  Sébastien Ourselin,et al.  Stability, structure and scale: improvements in multi-modal vessel extraction for SEEG trajectory planning , 2015, International Journal of Computer Assisted Radiology and Surgery.

[3]  Emanuele Trucco,et al.  Scale and Curvature Invariant Ridge Detector for Tortuous and Fragmented Structures , 2015, MICCAI.

[4]  Qingfen Lin,et al.  Enhancement, Extraction, and Visualization of 3D Volume Data , 2001 .

[5]  Yefeng Zheng,et al.  Coronary Centerline Extraction via Optimal Flow Paths and CNN Path Pruning , 2016, MICCAI.

[6]  David A. Steinman,et al.  An image-based modeling framework for patient-specific computational hemodynamics , 2008, Medical & Biological Engineering & Computing.

[7]  Danielle F. Pace,et al.  Studying Cerebral Vasculature Using Structure Proximity and Graph Kernels , 2013, MICCAI.

[8]  Sébastien Ourselin,et al.  Scale Factor Point Spread Function Matching: Beyond Aliasing in Image Resampling , 2015, MICCAI.

[9]  N. Ayache,et al.  Log‐Euclidean metrics for fast and simple calculus on diffusion tensors , 2006, Magnetic resonance in medicine.

[10]  Guido Gerig,et al.  3D Graph Description of the Intracerebral Vasculature from Segmented MRA and Tests of Accuracy by Comparison with X-ray Angiograms , 1999, IPMI.

[11]  Alan V.Oppenheim,et al.  “Discrete Time Signal Processing”, Pearson Education, 2nd edition, 2005. , 2015 .

[12]  Laurent D. Cohen,et al.  Tubular Structure Segmentation Based on Minimal Path Method and Anisotropic Enhancement , 2011, International Journal of Computer Vision.

[13]  Alejandro F. Frangi,et al.  Tensor-Based Graph-Cut in Riemannian Metric Space and Its Application to Renal Artery Segmentation , 2016, MICCAI.

[14]  Ghassan Hamarneh,et al.  VascuSynth: Simulating vascular trees for generating volumetric image data with ground-truth segmentation and tree analysis , 2010, Comput. Medical Imaging Graph..

[15]  Isabelle Bloch,et al.  A review of 3D vessel lumen segmentation techniques: Models, features and extraction schemes , 2009, Medical Image Anal..

[16]  Theo van Walsum,et al.  Bayesian Tracking of Tubular Structures and Its Application to Carotid Arteries in CTA , 2007, MICCAI.

[17]  Max W. K. Law,et al.  Three Dimensional Curvilinear Structure Detection Using Optimally Oriented Flux , 2008, ECCV.

[18]  Alan V. Oppenheim,et al.  Discrete-time Signal Processing. Vol.2 , 2001 .