Force observer-based control for a rehabilitation hand exoskeleton system

This paper is a component of a research project regarding the design and development of an Intelligent Haptic Robot-Glove for the rehabilitation of the patients that have a diagnosis of a cerebrovascular accident. In this paper, the control system for a rehabilitation hand exoskeleton is discussed. In order to avoid the complex problems given by a distributed sensor network, this paper treats the problem of the compliance force control by using observers: a velocity observer, a force observer and a disturbance observer. Two control solutions are discussed. First, the disturbance effects are eliminated by a cascade closed loop control with velocity and force observers. Then, a disturbance observer is used to compensate the compliance effects. The performance of the control systems is demonstrated by the simulation.

[1]  Subashan Perera,et al.  Rasch analysis of a new stroke-specific outcome scale: the Stroke Impact Scale. , 2003, Archives of physical medicine and rehabilitation.

[2]  M. Munih,et al.  HIFE-haptic interface for finger exercise , 2006, IEEE/ASME Transactions on Mechatronics.

[3]  Nikos G. Tsagarakis,et al.  Design of a Wearable Direct-driven Optimized Hand Exoskeleton Device , 2011, ACHI 2011.

[4]  L. E. Rodríguez-Cheu,et al.  Sensing and control of a prosthetic hand with myoelectric feedback , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..

[5]  Shuang Wang,et al.  Development of a hand exoskeleton system for index finger rehabilitation , 2012 .

[6]  Hendrik Van Brussel,et al.  Force control schemes for robot assembly , 1985 .

[7]  Yoky Matsuoka,et al.  An EMG-Controlled Hand Exoskeleton for Natural Pinching , 2004, J. Robotics Mechatronics.

[8]  Sébastien Krut A Force-Isotropic Underactuated Finger , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[9]  Clément Gosselin,et al.  Geometric Design of Three-Phalanx Underactuated Fingers , 2006 .

[10]  Dominiek Reynaerts,et al.  Control methods and actuation technology for whole-hand dexterous manipulation , 1995 .

[11]  Hong Liu,et al.  A Five-fingered Underactuated Prosthetic Hand Control Scheme , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..

[12]  Peter J. Gawthrop,et al.  A nonlinear disturbance observer for robotic manipulators , 2000, IEEE Trans. Ind. Electron..

[13]  Andreas Wege,et al.  Development and control of a hand exoskeleton for rehabilitation of hand injuries , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[14]  Peter J. Kyberd,et al.  MARCUS: a two degree of freedom hand prosthesis with hierarchical grip control , 1995 .

[15]  Clément Gosselin,et al.  Fuzzy Enhanced Control of an Underactuated Finger Using Tactile and Position Sensors , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[16]  Yoky Matsuoka,et al.  Comparison of control strategies for an EMG controlled orthotic exoskeleton for the hand , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[17]  Rahsaan J. Holley,et al.  Hand Spring Operated Movement Enhancer (HandSOME): A Portable, Passive Hand Exoskeleton for Stroke Rehabilitation , 2011, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[18]  Il Hong Suh,et al.  Disturbance observer based force control of robot manipulator without force sensor , 1998, Proceedings. 1998 IEEE International Conference on Robotics and Automation (Cat. No.98CH36146).

[19]  Bruno Siciliano,et al.  Parallel force/position control of a novel biomechatronic hand prosthesis , 2003, Proceedings 2003 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM 2003).

[20]  Ricardo Guerra,et al.  Velocity Observer for Mechanical Systems , 2008 .

[21]  Darren M. Dawson,et al.  A discontinuous output feedback controller and velocity observer for nonlinear mechanical systems , 2004, Autom..