Preliminary investigation on use of high‐resolution optical coherence tomography to monitor injury and repair in the rat sciatic nerve

Optical coherence tomography (OCT) has been used in limited settings to study peripheral nerve injury. The purpose of the study is to determine whether high‐resolution OCT can be used to monitor nerve injury and regeneration in the rat sciatic nerve following crush injury, ligation, and transection with microsurgical repair.

[1]  L. Sakata,et al.  Optical coherence tomography of the retina and optic nerve – a review , 2009, Clinical & experimental ophthalmology.

[2]  H. J. Seddon,et al.  THREE TYPES OF NERVE INJURY , 1943 .

[3]  I Hartl,et al.  Ultrahigh resolution real time OCT imaging using a compact femtosecond Nd:Glass laser and nonlinear fiber. , 2003, Optics express.

[4]  J. Kocsis,et al.  Synaptic Reorganization in the Substantia Gelatinosa After Peripheral Nerve Neuroma Formation: Aberrant Innervation of Lamina II Neurons by Aβ Afferents , 2000, The Journal of Neuroscience.

[5]  A. Varejão,et al.  Functional and morphological assessment of a standardized crush injury of the rat median nerve , 2009, Journal of Neuroscience Methods.

[6]  Malgorzata Mrugacz,et al.  Optical Coherence Tomography Measurement of the Retinal Nerve Fiber Layer in Normal and Juvenile Glaucomatous Eyes , 2005, Ophthalmologica.

[7]  Eric L Zager,et al.  Pathophysiology of peripheral nerve injury: a brief review. , 2004, Neurosurgical focus.

[8]  G Lundborg,et al.  A 25-year perspective of peripheral nerve surgery: evolving neuroscientific concepts and clinical significance. , 2000, Journal of Hand Surgery-American Volume.

[9]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991, LEOS '92 Conference Proceedings.

[10]  E. R. Andrew Nuclear magnetic resonance and the brain , 2005, Brain Topography.

[11]  S. Sunderland,et al.  Denervation atrophy of the distal stump of a severed nerve , 1950, The Journal of comparative neurology.

[12]  S. Sunderland The anatomy and physiology of nerve injury , 1990, Muscle & nerve.

[13]  U. Gerckens,et al.  Potential of a New High-Resolution Intracoronary Imaging Technique , 2003 .

[14]  H. Colt,et al.  Two-dimensional and 3-dimensional optical coherence tomographic imaging of the airway, lung, and pleura. , 2005, The Journal of thoracic and cardiovascular surgery.

[15]  B. Wong,et al.  In vivo optical coherence tomography of the human oral cavity and oropharynx. , 2006, Archives of otolaryngology--head & neck surgery.

[16]  Maciej Wojtkowski,et al.  Retinal assessment using optical coherence tomography , 2006, Progress in Retinal and Eye Research.

[17]  B. Wong,et al.  In Vivo Optical Coherence Tomography of the Nasal Mucosa , 2006, American journal of rhinology.

[18]  B. Wong,et al.  Imaging of the Pediatric Airway Using Optical Coherence Tomography , 2007, The Laryngoscope.

[19]  B. Goldberg,et al.  Sonographically guided laparoscopy and mediastinoscopy using miniature catheter‐based transducers , 1993, Journal of ultrasound in medicine.

[20]  J. Schuman,et al.  Optical coherence tomography. , 2000, Science.

[21]  R. Kikinis,et al.  Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications. , 1997, Neurosurgery.