An intercomparison of IMRT delivery techniques: a case study for breast treatment.

Intensity-modulated radiotherapy beams can be delivered using a multileaf collimator by one of two methods: either by superposition of a series of multiple-static fields, or by moving the collimators while the beam is on to produce 'dynamically' modulated beams. The leaf trajectories in this dynamic mode are given by a series of linear steps between control points defining each collimator position at known intervals throughout an exposure. The complexity of the resulting modulation is limited in the first case by the number of fields superposed and in the second case by the number of control points defined. Results are presented for an experimental study that investigates the effect of changing both the number of fields for the multiple-static technique, and the number of control points for a dynamic 'close-in' technique. All deliveries studied are clinical intensity-modulated breast fields. The effect of using a universal wedge in conjunction with the multileaf collimator is also studied, together with a comparison of the relative efficiency, time taken and the absolute dosimetric accuracy of the various delivery options. It is shown that all delivery techniques produce equivalent dose distributions when using 15 control points, with 10 control points being sufficient to produce an adequate breast compensator distribution. Except for the case of a four-control-point dynamic delivery, the universal wedge makes no significant difference to the dose distribution. However, it makes the delivery less efficient. The close-in interpreter consistently produces deliveries that are more efficient than the more conventional sliding-window technique and faster than the multiple-static-field technique. Finally the close-in technique is compared to the more 'standard' leaf-sweep technique and shown to be equivalent.

[1]  J O Deasy,et al.  Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. , 1993, Medical physics.

[2]  J M Wilkinson,et al.  Rectangular edge synchronization for intensity modulated radiation therapy with dynamic multileaf collimation. , 1998, Physics in medicine and biology.

[3]  R Mohan,et al.  Interinstitutional experience in verification of external photon dose calculations. , 1991, International journal of radiation oncology, biology, physics.

[4]  T. Bortfeld,et al.  X-ray field compensation with multileaf collimators. , 1994, International journal of radiation oncology, biology, physics.

[5]  Cedric X. Yu,et al.  Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy. , 1995, Physics in medicine and biology.

[6]  G J Budgell,et al.  Temporal resolution requirements for intensity modulated radiation therapy delivered by multileaf collimators. , 1999, Physics in medicine and biology.

[7]  A Brahme,et al.  Shaping of arbitrary dose distributions by dynamic multileaf collimation. , 1988, Physics in medicine and biology.

[8]  P M Evans,et al.  Practical implementation of compensators in breast radiotherapy. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  R Mohan,et al.  Compensators for three-dimensional treatment planning. , 1991, Medical physics.

[10]  S Webb,et al.  The dosimetric consequences of inter-fractional patient movement on conventional and intensity-modulated breast radiotherapy treatments. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  M Partridge,et al.  The delivery of intensity modulated radiotherapy to the breast using multiple static fields. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[12]  J. V. van Santvoort,et al.  Leaf trajectory calculation for dynamic multileaf collimation to realize optimized fluence profiles. , 1998, Physics in Medicine and Biology.

[13]  D. Convery,et al.  The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation , 1992 .

[14]  P M Evans,et al.  The optimum intensities for multiple static multileaf collimator field compensation. , 1997, Medical physics.

[15]  T LoSasso,et al.  Dosimetric verification of intensity-modulated fields. , 1996, Medical physics.