NEREUS/Kemonaut, a mobile autonomous underwater mass spectrometer

NEREUS is a self-contained underwater membrane-inlet mass spectrometer (MS) based on a cycloidal mass analyzer. Designed for autonomous operation, with a mass of 22 kg and a power consumption of less than 20 W, a NEREUS prototype was demonstrated in freshwater and marine environments to a depth of 25 m. The instrument was operated in both tethered and towed operation, as well as aboard Kemonaut, an Odyssey-class autonomous underwater vehicle (AUV) modified to accommodate the NEREUS instrument. The Kemonaut AUV greatly expands the range of environments that can practicably be investigated. NEREUS was demonstrated to measure many important metabolic gases, such as oxygen, methane, and carbon dioxide, at levels encountered in natural waters; it also responds to light hydrocarbon pollutants. Important goals for future instruments are increased capability to self-calibrate in situ and lowered detection limits that enable measurement of trace metabolic gases, such as hydrogen and nitrous oxide.

[1]  James E. Johnson Evaluation of a seawater equilibrator for shipboard analysis of dissolved oceanic trace gases , 1999 .

[2]  H. Hemond A backpack‐portable mass spectrometer for measurement of volatile compounds in the environment , 1991 .

[3]  G. Hoch,et al.  A mass spectrometer inlet system for sampling gases dissolved in liquid phases. , 1963, Archives of biochemistry and biophysics.

[4]  L. G. Hall,et al.  Small General Purpose Cycloidal‐Focusing Mass Spectrometer , 1956 .

[5]  Hanumant Singh,et al.  Issues in AUV design and deployment for oceanographic research , 1997, Proceedings of International Conference on Robotics and Automation.

[6]  H. Hemond,et al.  Nitrate Controls on Iron and Arsenic in an Urban Lake , 2002, Science.

[7]  R. T. Short,et al.  Underwater mass spectrometers for in situ chemical analysis of the hydrosphere , 2001, Journal of the American Society for Mass Spectrometry.

[8]  Richard Camilli,et al.  The development of components for an in-situ mass spectrometer , 2000 .

[9]  W. Bleakney,et al.  A New Mass Spectrometer with Improved Focusing Properties , 1938 .

[10]  R. Eganhouse,et al.  Anthropogenic organic contaminants in the effluent of a combined sewer overflow: impact on Boston Harbor. , 2001, Marine environmental research.

[11]  Richard Camilli,et al.  Creation and deployment of the NEREUS autonomous underwater chemical analyzer and Kemonaut, an odyssey class submarine , 2003 .

[12]  R. W. Kiser Introduction to Mass Spectrometry and Its Applications , 1965 .