Performance evaluation and modeling of a hybrid cooling system combining a screw water chiller with a ground source heat pump in a building

The performance of a hybrid cooling system that combines a screw water chiller with a ground source heat pump (GSHP) was measured and analyzed at various cooling loads. In addition, the hybrid cooling system in a building was modelled sophisticatedly using EnergyPlus and then validated with the measured data. The coefficient of performance of the GSHP was lower than that of a conventional chiller in the monitored building, but the hybrid cooling system helped to stably provide the required cooling capacity at high-load conditions. The mean bias error and the normalized root-mean squared error of the predicted cooling load of the building were −8% and 12.4%, respectively. The hybrid cooling system was simulated by varying four operating parameters: the operating schedule, chilled water temperature (TCW), dry-bulb temperature (TDB), and entering water temperature (TEW). The TCW is ascertained as being the most effective control parameter in the hybrid cooling system.

[1]  F. W. Yu,et al.  Improved energy performance of air cooled centrifugal chillers with variable chilled water flow , 2008 .

[2]  Xu Zhang,et al.  Research on Ground Temperature Restoration Characteristics of Large-Scale Ground Source Heat Pump System , 2008 .

[3]  F. W. Yu,et al.  Optimum condenser fan staging for air-cooled chillers , 2005 .

[4]  Chih Chien Tang,et al.  Modeling Packaged Heat Pumps in a Quasi-steady State Energy Simulation Program , 2005 .

[5]  Doosam Song,et al.  A Prediction of the Indoor Air Movement and Contaminant Concentration in a Multi-Room Condition , 2007 .

[6]  Jeffrey D. Spitler,et al.  A Parameter Estimation Based Model of Water-to-Water Heat Pumps for Use in Energy Calculation Programs , 2002 .

[7]  F. W. Yu,et al.  Optimum load sharing strategy for multiple-chiller systems serving air-conditioned buildings , 2007 .

[8]  Jung-Yeul Jung,et al.  Optimal planning and economic evaluation of cogeneration system , 2007 .

[9]  A. Hepbasli Thermodynamic analysis of a ground‐source heat pump system for district heating , 2005 .

[10]  Onder Ozgener,et al.  Modeling and performance evaluation of ground source (geothermal) heat pump systems , 2007 .

[11]  Richard C. Diamond,et al.  Performance validation and energy analysis of HVAC systems using simulation , 2000 .

[12]  Sankaranarayanan Padhmanabhan,et al.  Modeling, Verification and Optimization of Hybrid Ground Source Heat Pump Systems in Energyplus , 2005 .

[13]  Ruzhu Wang,et al.  Simulation and experimental validation of the variable-refrigerant-volume (VRV) air-conditioning system in EnergyPlus , 2008 .

[14]  Ruzhu Wang,et al.  Energy simulation in the variable refrigerant flow air-conditioning system under cooling conditions , 2007 .

[15]  Ming Qu,et al.  A review for the applications and integrated approaches of ground-coupled heat pump systems , 2011 .