Rapid protein digestion and identification using monolithic enzymatic microreactor coupled with nano-liquid chromatography-electrospray ionization mass spectrometry.

A novel monolithic enzymatic microreactor was prepared in the fused-silica capillary by in situ polymerization of acrylamide (AA), N-acryloxysuccinimide (NAS) and ethylene dimethacrylate (EDMA) in the presence of a binary porogenic mixture of dodecanol and cyclohexanol, which could offer very low back pressure, enabling the fast digestion of proteins. The performance of the monolithic microreactor was demonstrated by digesting cytochrome c at high flow rate, and the comparisons between the in-solution digestion and on-column reaction were made by a nano-high performance liquid chromatography-mass spectrometry (nano-HPLC-MS) system. The performance of the monolithic microreactor was demonstrated with the digestion of cytochrome c at the fast flow rate of 1 microL/min, which afforded a residence time of 7s, yielding a sequence coverage of 54.81% using strict multiple database searching thresholds. Future more, a mixture of four standard proteins was digested and analyzed using the on-line digestion and nano-HPLC-MS system. The results showed the promising of such a system in the analysis of protein mixture.

[1]  R. Aebersold,et al.  Mass spectrometry in proteomics. , 2001, Chemical reviews.

[2]  D. Josić,et al.  Monoliths as stationary phases for separation of proteins and polynucleotides and enzymatic conversion. , 2001, Journal of chromatography. B, Biomedical sciences and applications.

[3]  J. Yates,et al.  Charting the Protein Complexome in Yeast by Mass Spectrometry* , 2002, Molecular & Cellular Proteomics.

[4]  J. Fréchet,et al.  Design of reactive porous polymer supports for high throughput bioreactors: poly(2-vinyl-4,4-dimethylazlactone-co-acrylamide- co-ethylene dimethacrylate) monoliths. , 1999, Biotechnology and bioengineering.

[5]  J. Yates Mass spectrometry and the age of the proteome. , 1998, Journal of mass spectrometry : JMS.

[6]  J. V. Van Beeumen,et al.  Automated nanoflow liquid chromatography-tandem mass spectrometry for a differential display proteomic study on Xenopus laevis neuroendocrine cells. , 2002, Journal of chromatography. A.

[7]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[8]  J. Yates,et al.  An automated multidimensional protein identification technology for shotgun proteomics. , 2001, Analytical chemistry.

[9]  G. Massolini,et al.  Trypsin-based monolithic bioreactor coupled on-line with LC/MS/MS system for protein digestion and variant identification in standard solutions and serum samples. , 2005, Journal of Proteome Research.

[10]  G. Massolini,et al.  Development of a bioreactor based on trypsin immobilized on monolithic support for the on-line digestion and identification of proteins. , 2004, Journal of chromatography. A.

[11]  Kazunori Yamada,et al.  Retention and reusability of trypsin activity by covalent immobilization onto grafted polyethylene plates , 2003 .

[12]  C. Ihling,et al.  Nano-high-performance liquid chromatography in combination with nano-electrospray ionization Fourier transform ion-cyclotron resonance mass spectrometry for proteome analysis. , 2003, Rapid communications in mass spectrometry : RCM.

[13]  E. Hilder,et al.  Polymeric monolithic stationary phases for capillary electrochromatography , 2002, Electrophoresis.

[14]  Frantisek Svec,et al.  Enzymatic microreactor-on-a-chip: protein mapping using trypsin immobilized on porous polymer monoliths molded in channels of microfluidic devices. , 2002, Analytical chemistry.

[15]  T. Rohr,et al.  High-throughput peptide mass mapping using a microdevice containing trypsin immobilized on a porous polymer monolith coupled to MALDI TOF and ESI TOF mass spectrometers. , 2002, Journal of proteome research.

[16]  D. Muddiman,et al.  Nanoelectrospray mass spectrometry using non‐metalized, tapered (50 → 10 μm) fused‐silica capillaries , 1998 .

[17]  Gordon W. Slysz,et al.  Blending protein separation and peptide analysis through real-time proteolytic digestion. , 2005, Analytical chemistry.

[18]  Frantisek Svec,et al.  Dual-function microanalytical device by in situ photolithographic grafting of porous polymer monolith: integrating solid-phase extraction and enzymatic digestion for peptide mass mapping. , 2003, Analytical chemistry.

[19]  J Godovac-Zimmermann,et al.  Perspectives for mass spectrometry and functional proteomics. , 2001, Mass spectrometry reviews.

[20]  S. Jacobson,et al.  Microchip device for performing enzyme assays. , 1997, Analytical chemistry.

[21]  T. Rohr,et al.  Porous polymer monoliths: Simple and efficient mixers prepared by direct polymerization in the channels of microfluidic chips , 2001, Electrophoresis.

[22]  Cheng S. Lee,et al.  Membrane-based nanoscale proteolytic reactor enabling protein digestion, peptide separation, and protein identification using mass spectrometry. , 2003, Analytical chemistry.

[23]  M. Novotny,et al.  Analytical characterization of a facile porous polymer monolithic trypsin microreactor enabling peptide mass mapping using mass spectrometry. , 2004, Rapid communications in mass spectrometry : RCM.

[24]  James P Landers,et al.  A microchip-based proteolytic digestion system driven by electroosmotic pumping. , 2003, Lab on a chip.

[25]  J. Greef,et al.  A novel sheathless and electrodeless microelectrospray interface for the on‐line coupling of capillary zone electrophoresis to mass spectrometry , 1997 .

[26]  Richard D. Smith,et al.  High-efficiency nanoscale liquid chromatography coupled on-line with mass spectrometry using nanoelectrospray ionization for proteomics. , 2002, Analytical chemistry.

[27]  F. Regnier,et al.  Protein proteolysis and the multi-dimensional electrochromatographic separation of histidine-containing peptide fragments on a chip. , 2003, Journal of chromatography. A.

[28]  J. Fréchet,et al.  Monolithic, “Molded”, Porous Materials with High Flow Characteristics for Separations, Catalysis, or Solid-Phase Chemistry: Control of Porous Properties during Polymerization , 1996 .

[29]  T. Toyo’oka,et al.  On-line trypsin-encapsulated enzyme reactor by the sol-gel method integrated into capillary electrophoresis. , 2002, Analytical chemistry.

[30]  Masaru Kato,et al.  Creation of an on-chip enzyme reactor by encapsulating trypsin in sol-gel on a plastic microchip. , 2003, Analytical chemistry.

[31]  Arthur H. Smith Principles of Biochemistry , 1955 .

[32]  T Laurell,et al.  Integrated microanalytical technology enabling rapid and automated protein identification. , 2000, Analytical chemistry.

[33]  S. Ekström,et al.  Improved performance in silicon enzyme microreactors obtained by homogeneous porous silicon carrier matrix. , 2002, Talanta.

[34]  L. Locascio,et al.  Integrated microfluidic system enabling protein digestion, peptide separation, and protein identification. , 2001, Analytical chemistry.

[35]  Yasushi Ishihama,et al.  Proteomic LC-MS systems using nanoscale liquid chromatography with tandem mass spectrometry. , 2005, Journal of chromatography. A.

[36]  D. Kiehl,et al.  Separation and characterization of the tryptic peptide mapping of recombinant bovine growth hormone by reversed-phase high-performance liquid chromatography electrospray mass spectrometry. , 1997, Rapid communications in mass spectrometry : RCM.

[37]  Regine M. Schoenherr,et al.  On‐line protein digestion and peptide mapping by capillary electrophoresis with post‐column labeling for laser‐induced fluorescence detection , 2004, Electrophoresis.

[38]  J. Ramsey,et al.  On-chip proteolytic digestion and analysis using "wrong-way-round" electrospray time-of-flight mass spectrometry. , 2001, Analytical chemistry.

[39]  J. Yates,et al.  Large-scale analysis of the yeast proteome by multidimensional protein identification technology , 2001, Nature Biotechnology.

[40]  Jean M. J. Fréchet,et al.  New Designs of Macroporous Polymers and Supports: From Separation to Biocatalysis , 1996, Science.

[41]  K. Waldron,et al.  Reproducibility of a solid-phase trypsin microreactor for peptide mapping by capillary electrophoresis , 2000 .

[42]  Gordon W. Slysz,et al.  On-column digestion of proteins in aqueous-organic solvents. , 2003, Rapid communications in mass spectrometry : RCM.

[43]  J. Yates,et al.  Direct analysis of protein complexes using mass spectrometry , 1999, Nature Biotechnology.

[44]  M Petro,et al.  Immobilization of trypsin onto “molded” macroporous poly(glycidyl methacrylate‐co‐ethylene dimethacrylate) rods and use of the conjugates as bioreactors and for affinity chromatography , 2000, Biotechnology and bioengineering.

[45]  S. Gygi,et al.  Mass spectrometry and proteomics. , 2000, Current opinion in chemical biology.