A comparison of the mechanical, kinetic, and biochemical properties of fibrin clots formed with two different fibrin sealants

The objective of the present study was to compare the mechanical, kinetic, and biochemical properties of fibrin clots produced using EVICEL Fibrin Sealant (Human) and TISSEEL Fibrin Sealant. The stiffness/elasticity and strength of fibrin clots formed with EVICEL and TISSEEL were assessed using applied mechanical force and thromboelastography (TEG). The factor XIII content of the fibrin clots was also evaluated. Mean Young modulus and tensile strength of the fibrin clots produced by EVICEL were significantly higher than those of clots produced by TISSEEL (P < 0.05 for both). The mean time to initial clot formation and mean time to the predefined level of clot formation were numerically shorter for EVICEL compared with TISSEEL. Furthermore, mean maximal amplitude of the clots formed with EVICEL was significantly greater than that for the clots formed with TISSEEL. Mean concentration of factor XIII for the EVICEL fibrinogen samples tested was 9 IU/ml compared with undetectable concentrations of factor XIII for the TISSEEL fibrinogen samples. Fibrin clots formed with EVICEL have a much higher resistance to stretching and tensile strength and are more capable of maintaining their structure against applied force than those formed with TISSEEL. EVICEL also allows more rapid development of fibrin clots than TISSEEL. This superior clot strength and resilience obtained with EVICEL relative to TISSEEL may be due in large part to the presence of factor XIII.

[1]  William D Spotnitz,et al.  Fibrin Sealant Improves Hemostasis in Peripheral Vascular Surgery: A Randomized Prospective Trial , 2003, Annals of surgery.

[2]  J. Owen,et al.  Comparative analysis of biomechanical performance of available "nerve glues". , 2008, The Journal of hand surgery.

[3]  Mosesson Mw Fibrinogen and fibrin polymerization: appraisal of the binding events that accompany fibrin generation and fibrin clot assembly. , 1997 .

[4]  E. Eviatar,et al.  Fibrin sealant: alternative to nasal packing in endonasal operations. A prospective randomized study. , 2005, The Israel Medical Association journal : IMAJ.

[5]  Thomas Pfeifer,et al.  A comparison of fibrin sealants in relation to their in vitro and in vivo properties. , 2003, Thrombosis research.

[6]  R. Carrau,et al.  Use of Tisseel fibrin sealant in neurosurgical procedures: incidence of cerebrospinal fluid leaks and cost-benefit analysis in a retrospective study. , 2003, Neurosurgery.

[7]  K. Cahill,et al.  Fibrin Sealant for Müller Muscle–Conjunctiva Resection Ptosis Repair , 2006, Ophthalmic plastic and reconstructive surgery.

[8]  H. Metzner,et al.  Fibrin sealants in supporting surgical techniques: strength in factor XIII. , 2003, Cardiovascular surgery.

[9]  J. Holcomb,et al.  Comparative study of the hemostatic efficacy of a new human fibrin sealant: is an antifibrinolytic agent necessary? , 2002, The Journal of trauma.

[10]  Pradnya D Mohile,et al.  A prospective, randomized trial evaluating the safety and efficacy of fibrin sealant in tubeless percutaneous nephrolithotomy. , 2006, The Journal of urology.

[11]  S. Wood,et al.  A prospective, randomized, double-blind trial of the use of fibrin sealant for face lifts. , 2001, Plastic and reconstructive surgery.

[12]  D. Albala,et al.  Recent clinical and investigational applications of fibrin sealant in selected surgical specialties. , 2006, Journal of the American College of Surgeons.

[13]  C Longstaff,et al.  Studies on the mechanisms of action of aprotinin and tranexamic acid as plasmin inhibitors and antifibrinolytic agents. , 1994, Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis.

[14]  M. Mosesson Fibrinogen and fibrin polymerization: appraisal of the binding events that accompany fibrin generation and fibrin clot assembly. , 1997, Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis.

[15]  N. Heaton,et al.  Comparison of a new fibrin sealant with standard topical hemostatic agents. , 2004, Archives of surgery.

[16]  R. Cornwell,et al.  Reproducibility of the mechanical properties of Vivostat system patient-derived fibrin sealant. , 2002, Biomaterials.

[17]  H. Mischinger,et al.  Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial , 2005, Langenbeck's Archives of Surgery.