Case studies Indoor environment and conservation in the Royal Museum of Fine Arts, Antwerp, Belgium

Indoor and outdoor atmospheres of the ‘Koninklijk Museum voor Schone Kunsten’ (KMSK, Royal Museum of Fine Arts) in Antwerp, Belgium, were thoroughly characterised to determine the air quality inside the museum and the factors controlling it. During a winter and a summer campaign aerosol particles, pollutant gases, bacteria and fungi were sampled and different indoors microclimatic parameters were measured. The chemical composition of particulates suspended in indoor and outdoor air was analysed, both with reference to bulk aerosol matter and to individual particles. Outdoor sources largely determined the composition of indoor aerosol. The main particle types identified in winter were Ca-rich, Ca–Si and sea salt particles. In summer, S-rich particles were most abundant. Dry deposition was sampled in order to determine the amount of particulate matter that could potentially deposit onto the works of art. The concentrations of NO2 and SO2 amounted to 12 and 5–6 ppb, respectively, both in winter and in the summer. The microclimates inside the exhibition rooms were affected by poorly balanced heating and air-conditioning, free-standing humidifiers, ventilating and lighting systems and the daily flux of visitors, which produced rapid changes and marked thermo-hygrometric gradients. Based on these results, suggestions for the improvement of the heating and air-conditioning system could be made. Microbial loads were higher in summer than in winter. However, the proportion of microorganisms capable of degrading proteins or hydrolysing fats, and thus pernicious to works of art, was not significantly increased inside the museum. © 2004 Elsevier SAS. All rights reserved.

[1]  F. Santis,et al.  Determination of some atmospheric pollutants inside a museum: relationship with the concentration outside , 1992 .

[2]  R. Grieken,et al.  A study of the weathering of an historic building , 1987 .

[3]  P Brimblecombe,et al.  Indoor air quality at the Correr Museum, Venice, Italy. , 1999, The Science of the total environment.

[4]  Petra Altenburgera,et al.  Classification of bacteria isolated from a medieval wall painting , 1996 .

[5]  W. Krumbein,et al.  Biocorrosion and biodeterioration of antique and medieval glass , 1991 .

[6]  H. Busse,et al.  Rapid identification of Staphylococcus epidermidis. , 2000, International journal of systematic and evolutionary microbiology.

[7]  Dario Camuffo,et al.  Microclimate for Cultural Heritage , 1998 .

[8]  Peter Brimblecombe,et al.  Multidisciplinary Environmental Monitoring at the Kunsthistorisches Museum, Vienna , 2003 .

[9]  Tracy L. Thatcher,et al.  Deposition, resuspension, and penetration of particles within a residence , 1995 .

[10]  R. Harrison,et al.  Analysis and interpretation of measurements of suspended particulate matter at urban background sites in the United Kingdom , 1997 .

[11]  Paul N. Banks,et al.  Indoor air pollution: Effects on cultural and historic materials , 1985 .

[12]  P Brimblecombe,et al.  The indoor environment of a modern museum building, the Sainsbury Centre for Visual Arts, Norwich, UK. , 1999, Indoor air.

[13]  R. Van Grieken,et al.  Environmental monitoring in four European museums , 2001 .

[14]  G. Thomson Air pollution. A review for conservation chemists , 1965 .