Qualitative and quantitative evaluation of rigid and deformable motion correction algorithms using dual-energy CT images in view of application to CT perfusion measurements in abdominal organs affected by breathing motion.

OBJECTIVE To compare six different scenarios for correcting for breathing motion in abdominal dual-energy CT (DECT) perfusion measurements. METHODS Rigid [RRComm(80 kVp)] and non-rigid [NRComm(80 kVp)] registration of commercially available CT perfusion software, custom non-rigid registration [NRCustom(80 kVp], demons algorithm) and a control group [CG(80 kVp)] without motion correction were evaluated using 80 kVp images. Additionally, NRCustom was applied to dual-energy (DE)-blended [NRCustom(DE)] and virtual non-contrast [NRCustom(VNC)] images, yielding six evaluated scenarios. After motion correction, perfusion maps were calculated using a combined maximum slope/Patlak model. For qualitative evaluation, three blinded radiologists independently rated motion correction quality and resulting perfusion maps on a four-point scale (4 = best, 1 = worst). For quantitative evaluation, relative changes in metric values, R(2) and residuals of perfusion model fits were calculated. RESULTS For motion-corrected images, mean ratings differed significantly [NRCustom(80 kVp) and NRCustom(DE), 3.3; NRComm(80 kVp), 3.1; NRCustom(VNC), 2.9; RRComm(80 kVp), 2.7; CG(80 kVp), 2.7; all p < 0.05], except when comparing NRCustom(80 kVp) with NRCustom(DE) and RRComm(80 kVp) with CG(80 kVp). NRCustom(80 kVp) and NRCustom(DE) achieved the highest reduction in metric values [NRCustom(80 kVp), 48.5%; NRCustom(DE), 45.6%; NRComm(80 kVp), 29.2%; NRCustom(VNC), 22.8%; RRComm(80 kVp), 0.6%; CG(80 kVp), 0%]. Regarding perfusion maps, NRCustom(80 kVp) and NRCustom(DE) were rated highest [NRCustom(80 kVp), 3.1; NRCustom(DE), 3.0; NRComm(80 kVp), 2.8; NRCustom(VNC), 2.6; CG(80 kVp), 2.5; RRComm(80 kVp), 2.4] and had significantly higher R(2) and lower residuals. Correlation between qualitative and quantitative evaluation was low to moderate. CONCLUSION Non-rigid motion correction improves spatial alignment of the target region and fit of CT perfusion models. Using DE-blended and DE-VNC images for deformable registration offers no significant improvement. ADVANCES IN KNOWLEDGE Non-rigid algorithms improve the quality of abdominal CT perfusion measurements but do not benefit from DECT post processing.

[1]  Thomas Flohr,et al.  Image Fusion in Dual Energy Computed Tomography: Effect on Contrast Enhancement, Signal-to-Noise Ratio and Image Quality in Computed Tomography Angiography , 2009, Investigative radiology.

[2]  K. Miles,et al.  Perfusion CT for the assessment of tumour vascularity: which protocol? , 2003, The British journal of radiology.

[3]  Patrik Rogalla,et al.  Whole-organ perfusion of the pancreas using dynamic volume CT in patients with primary pancreas carcinoma: acquisition technique, post-processing and initial results , 2009, European Radiology.

[4]  Wei Wei,et al.  Semiautomated motion correction of tumors in lung CT-perfusion studies. , 2011, Academic radiology.

[5]  F. Rademakers,et al.  ROOT — An object oriented data analysis framework , 1997 .

[6]  W. Kalender,et al.  An algorithm for noise suppression in dual energy CT material density images. , 1988, IEEE transactions on medical imaging.

[7]  Jean-Philippe Thirion,et al.  Image matching as a diffusion process: an analogy with Maxwell's demons , 1998, Medical Image Anal..

[8]  John D. Owens,et al.  Fast Deformable Registration on the GPU: A CUDA Implementation of Demons , 2008, 2008 International Conference on Computational Sciences and Its Applications.

[9]  D. Hill,et al.  Non-rigid image registration: theory and practice. , 2004, The British journal of radiology.

[10]  Ting-Yim Lee Functional CT: physiological models , 2002 .

[11]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[12]  P. Shrimpton,et al.  Assessment of Patient Dose in CT , 2004 .

[13]  J. Nocedal,et al.  A Limited Memory Algorithm for Bound Constrained Optimization , 1995, SIAM J. Sci. Comput..

[14]  Pierre Bedossa,et al.  Pancreatic endocrine tumors: tumor blood flow assessed with perfusion CT reflects angiogenesis and correlates with prognostic factors. , 2009, Radiology.

[15]  S Rees,et al.  Measurement of tissue perfusion by dynamic computed tomography. , 1992, The British journal of radiology.

[16]  K. Miles,et al.  Perfusion CT: a worthwhile enhancement? , 2003, The British journal of radiology.

[17]  M. Reiser,et al.  Material differentiation by dual energy CT: initial experience , 2007, European Radiology.

[18]  Arno Klein,et al.  Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration , 2009, NeuroImage.

[19]  A Chandler,et al.  Validation of motion correction techniques for liver CT perfusion studies. , 2012, The British journal of radiology.

[20]  M Kieser,et al.  Dual-energy perfusion-CT of pancreatic adenocarcinoma. , 2013, European journal of radiology.

[21]  C. Patlak,et al.  Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data. Generalizations , 1985, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.