Impact of quantitatively determined native thoracic aortic tortuosity on endoleak development after thoracic endovascular aortic repair.

OBJECTIVE The objective of our study was to assess whether there is an association between native thoracic aortic curvature and the development of endoleaks after thoracic endovascular aortic repair. MATERIALS AND METHODS Quantitative analysis of the native aortic lumen was performed on preprocedural CT angiograms of 40 patients with thoracic aortic aneurysm treated by thoracic endovascular aortic repair. The curvature of the median centerline was measured. Tortuosity indexes were calculated on the basis of the sum of the curvature values within the diseased segment and in the proximal and distal fixation zones. The association between the tortuosity index and endoleak was analyzed. RESULTS Compared with patients without endoleaks, the tortuosity index of the proximal fixation zone was higher in patients with type Ia endoleak (9.5 vs 1.5 cm(-1), p < 0.01); the tortuosity index of the distal fixation zone was higher in type Ib endoleak patients (6.6 vs 0.5 cm(-1), p < 0.05); and the tortuosity indexes of the proximal fixation zone and of the diseased segment were higher in type III endoleak patients (11.0 vs 1.5 cm(-1), p < 0.01; and 15.8 vs 7.2 cm(-1), p < 0.01, respectively). Patients with a type III endoleak had longer diseased segments and larger mean diameters of the aneurysm than patients without endoleaks (148.6 vs 87.1 mm, p < 0.01; and 75.4 vs 63.2 mm, p < 0.05, respectively). Logistic regression analysis revealed that the risk of a type I or type III endoleak increased as the tortuosity index increased, with a 90% risk of endoleak at a tortuosity index of 10 cm(-1) in the proximal fixation zone. CONCLUSION Quantification of aortic tortuosity using CT angiograms may help to predict whether an endoleak will develop after thoracic endovascular aortic repair, and this quantification method may become an important tool for risk stratification before thoracic endovascular aortic repair.

[1]  Automated quantification of aortoaortic and aortoiliac angulation for computed tomographic angiography of abdominal aortic aneurysms before endovascular repair: preliminary study. , 2010, Journal of vascular and interventional radiology : JVIR.

[2]  Jae-Sung Cho,et al.  US multicenter trials of endoprostheses for the endovascular treatment of descending thoracic aneurysms. , 2006, Journal of vascular surgery.

[3]  William E. Lorensen,et al.  Marching cubes: A high resolution 3D surface construction algorithm , 1987, SIGGRAPH.

[4]  B. Lytle,et al.  Endovascular repair of thoracic aortic lesions with the Zenith TX1 and TX2 thoracic grafts: intermediate-term results. , 2005, Journal of vascular surgery.

[5]  J. Bavaria,et al.  Endoleaks after endovascular repair of thoracic aortic aneurysms. , 2006, Journal of vascular surgery.

[6]  P. Faries,et al.  The Role of Anatomic Factors in Predicting Success of Endovascular Repair of Thoracic Aortic Aneurysms , 2010, Vascular and endovascular surgery.

[7]  Luigi de Luca Tupputi Schinosa,et al.  Endovascular Treatment of Thoracic Aortic Disease: Four Years of Experience , 2004, Circulation.

[8]  S. Napel,et al.  Prediction of aortoiliac stent-graft length: comparison of measurement methods. , 2001, Radiology.

[9]  F. Veith,et al.  Endoleaks and Endotension : Current Consensus on Their Nature and Significance , 2002 .

[10]  M. Eskandari,et al.  Endovascular repair of thoracic aortic tears. , 2006, The Annals of thoracic surgery.

[11]  D S Paik,et al.  Measurement of the aorta and its branches with helical CT. , 1998, Radiology.

[12]  D. Obrand,et al.  The Proximal Landing Zone in Endovascular Repair of the Thoracic Aorta , 2004, Annals of vascular surgery.

[13]  Rodney A. White,et al.  Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference. , 2002, Journal of vascular surgery.

[14]  F. Setacci,et al.  Results of endografting of the aortic arch in different landing zones. , 2007, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[15]  G. Rubin,et al.  Impact of aortoiliac tortuosity on endovascular repair of abdominal aortic aneurysms: evaluation of 3D computer-based assessment. , 2001, Journal of vascular surgery.

[16]  C. Nienaber,et al.  Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement. , 1999, The New England journal of medicine.

[17]  K. Harris,et al.  Endovascular Repair of Thoracic Aortic Disease: Early and Midterm Experience , 2007, Vascular and endovascular surgery.

[18]  E LorensenWilliam,et al.  Marching cubes: A high resolution 3D surface construction algorithm , 1987 .

[19]  S. Money,et al.  Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: results from the Zenith Multicenter Trial. , 2004, Journal of vascular surgery.

[20]  J. Bavaria,et al.  Thoracic aortic stent grafting: improving results with newer generation investigational devices. , 2006, The Journal of thoracic and cardiovascular surgery.

[21]  M. Czerny,et al.  Results After Endovascular Stent Graft Placement in Atherosclerotic Aneurysms Involving the Descending Aorta , 2007 .

[22]  S. Pizer,et al.  Measuring tortuosity of the intracerebral vasculature from MRA images , 2003, IEEE Transactions on Medical Imaging.

[23]  G D Rubin,et al.  Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography. , 2000, Radiology.

[24]  P Bergeron,et al.  Identification of proximal landing zone limit for proper deployment of aortic arch stentgraft after supra-aortic great vessels transposition. , 2007, The Journal of cardiovascular surgery.

[25]  Jarrett Rosenberg,et al.  Factors Portending Endoleak Formation After Thoracic Aortic Stent-Graft Repair of Complicated Aortic Dissection , 2009, Circulation. Cardiovascular interventions.

[26]  C. Peña,et al.  Sixty-four-detector CT angiography of infrarenal aortic neck length and angulation: prospective analysis of interobserver variability. , 2008, Journal of vascular and interventional radiology : JVIR.

[27]  D S Paik,et al.  Automated flight path planning for virtual endoscopy. , 1998, Medical physics.

[28]  R. S. Mitchell,et al.  Expert consensus document on the treatment of descending thoracic aortic disease using endovascular stent-grafts. , 2008, The Annals of thoracic surgery.

[29]  D S Paik,et al.  Iliac arterial injuries after endovascular repair of abdominal aortic aneurysms: correlation with iliac curvature and diameter. , 2001, Radiology.