Inter-comparison of low-cost sensors for measuring the mass concentration of occupational aerosols

ABSTRACT Low-cost sensors are effective for measuring the mass concentration of ambient aerosols and second-hand smoke in homes, but their use at concentrations relevant to occupational settings has not been demonstrated. We measured the concentrations of four aerosols (salt, Arizona road dust, welding fume, and diesel exhaust) with three types of low-cost sensors (a DC1700 from Dylos and two commodity sensors from Sharp), an aerosol photometer, and reference instruments at concentrations up to 6500 µg/m3. Raw output was used to assess sensor precision and develop equations to compute mass concentrations. EPA and NIOSH protocols were used to assess the mass concentrations estimated with low-cost sensors compared to reference instruments. The detection efficiency of the DC1700 ranged from 0.04% at 0.1 µm to 108% at 5 µm, as expected, although misclassification of fine and coarse particles was observed. The raw output of the DC1700 had higher precision (lower coefficient of variation, CV = 7.4%) than that of the two sharp devices (CV = 25% and 17%), a finding attributed to differences in manufacturer calibration. Aerosol type strongly influenced sensor response, indicating the need for on-site calibration to convert sensor output to mass concentration. Once calibrated, however, the mass concentration estimated with low-cost sensors was highly correlated with that of reference instruments (R2= 0.99). These results suggest that the DC1700 and Sharp sensors are useful in estimating aerosol mass concentration for aerosols at concentrations relevant to the workplace. © 2016 American Association for Aerosol Research

[1]  J. Seinfeld,et al.  Atmospheric Chemistry and Physics: From Air Pollution to Climate Change , 1997 .

[2]  V. Grassian,et al.  A laboratory investigation of light scattering from representative components of mineral dust aerosol at a wavelength of 550 nm , 2008 .

[3]  J. Antonini,et al.  Health Effects of Welding , 2003, Critical reviews in toxicology.

[4]  M D Attfield,et al.  Respiratory symptoms and spirometry in experienced coal miners: effects of both distant and recent coal mine dust exposures. , 1997, American journal of industrial medicine.

[5]  Chun Lin,et al.  Personal exposure monitoring of PM2.5 in indoor and outdoor microenvironments. , 2015, The Science of the total environment.

[6]  D. Holstius,et al.  Field calibrations of a low-cost aerosol sensor at a regulatory monitoring site in California , 2014 .

[7]  罗杰·L.·昂格尔 Compact, low cost particle sensor , 2008 .

[8]  Jaime E Hart,et al.  Occupational diesel exhaust exposure as a risk factor for chronic obstructive pulmonary disease , 2012, Current opinion in pulmonary medicine.

[9]  M Lipsett,et al.  Occupational exposure to diesel exhaust and lung cancer: a meta-analysis. , 1999, American journal of public health.

[10]  Rudolf B. Husar,et al.  Atmospheric particulate mass measurement with beta attenuation mass monitor , 1976 .

[11]  P. Mcmurry,et al.  Structural Properties of Diesel Exhaust Particles Measured by Transmission Electron Microscopy (TEM): Relationships to Particle Mass and Mobility , 2004 .

[12]  D. Dockery,et al.  An association between air pollution and mortality in six U.S. cities. , 1993, The New England journal of medicine.

[13]  Yang Wang,et al.  Laboratory Evaluation and Calibration of Three Low-Cost Particle Sensors for Particulate Matter Measurement , 2015 .

[14]  Sean Semple,et al.  An inexpensive particle monitor for smoker behaviour modification in homes , 2012, Tobacco Control.

[15]  Tracy Allen,et al.  A low-cost particle counter as a realtime fine-particle mass monitor. , 2013, Environmental science. Processes & impacts.

[16]  Neil E. Klepeis,et al.  Promoting Smoke-Free Homes: A Novel Behavioral Intervention Using Real-Time Audio-Visual Feedback on Airborne Particle Levels , 2013, PloS one.

[17]  W. Grant Air pollution in relation to U.S. cancer mortality rates: an ecological study; likely role of carbonaceous aerosols and polycyclic aromatic hydrocarbons. , 2009, Anticancer research.

[18]  P. Görner,et al.  Photometer measurement of polydisperse aerosols , 1995 .

[19]  Darrin K. Ott,et al.  Comparison of the Grimm 1.108 and 1.109 portable aerosol spectrometer to the TSI 3321 aerodynamic particle sizer for dry particles. , 2006, The Annals of occupational hygiene.

[20]  K. Sakamoto,et al.  Examination of discrepancies between beta-attenuation and gravimetric methods for the monitoring of particulate matter , 2008 .

[21]  Matthias Budde,et al.  Investigating the use of commodity dust sensors for the embedded measurement of particulate matter , 2012, 2012 Ninth International Conference on Networked Sensing (INSS).

[22]  William E. Wilson,et al.  Measurement of total PM2.5 mass (nonvolatile plus semivolatile) with the Filter Dynamic Measurement System tapered element oscillating microbalance monitor , 2005 .

[23]  Jost Heintzenberg,et al.  Design and Applications of the Integrating Nephelometer: A Review , 1996 .

[24]  G. Mulholland,et al.  Structural Property Effect of Nanoparticle Agglomerates on Particle Penetration through Fibrous Filter , 2009 .