Misalignment contribution to the autocollimator's scale distortion

In this article we present a new method for measuring the misalignment distortion caused by the lenses of the system used as a visual interface for a Nikon 6B autocollimator. This interface is used for making angle measurements using image processing techniques. This research paper studies the interaction between the optical systems of the interface's camera and the autocollimator. With the proposed method it is possible to quantify tolerances for the assembly process of the camera with the autocollimator. Furthermore, it is possible to quantify the contribution of the camera's misalignment induced by the environment (thermal gradients, for example) to the uncertainty in the autocollimator's scale calibration.

[1]  Ana Georgina Flesia,et al.  External visual interface for a Nikon 6D autocollimator , 2014, 2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings.

[2]  T. Clarke,et al.  The Development of Camera Calibration Methods and Models , 1998 .

[3]  James R. Pekelsky,et al.  Bootstrap calibration of an autocollimator, index table and sine bar ensemble for angle metrology , 2005, SPIE Optics + Photonics.

[4]  E. Hecht Optics 4th Edition , 1998 .

[5]  Carlos Ricolfe-Viala,et al.  Correcting non-linear lens distortion in cameras without using a model , 2010 .

[6]  Ralf D. Geckeler,et al.  Distance-dependent influences on angle metrology with autocollimators in deflectometry , 2008, Optical Engineering + Applications.

[7]  Alessandro Ferrero,et al.  Camera as the instrument: the rising trend of vision based measurement , 2014, IEEE Instrumentation & Measurement Magazine.

[8]  Guangjun Zhang,et al.  Calibrating camera radial distortion with cross-ratio invariability , 2003 .

[9]  Luis Canali,et al.  Electronic Interface With Vignetting Effect Reduction for a Nikon 6B/6D Autocollimator , 2015, IEEE Transactions on Instrumentation and Measurement.

[10]  Ana Georgina Flesia,et al.  Sub-pixel straight lines detection for measuring through machine vision , 2014, 2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings.

[11]  David Hessel,et al.  Photogrammetric Measurement Error Associated with Lens Distortion , 2011 .

[12]  Jannick P. Rolland,et al.  Recent discoveries from nodal aberration theory , 2010, International Optical Design Conference.

[13]  J. Reznícek METHOD FOR MEASURING LENS DISTORTION BY USING PINHOLE LENS , 2014 .

[14]  A. Paolillo,et al.  Metrological performances of camera self-calibration techniques , 2008, 2008 IEEE Instrumentation and Measurement Technology Conference.

[15]  Ralf D. Geckeler,et al.  Optimized use and calibration of autocollimators in deflectometry , 2007, SPIE Optical Engineering + Applications.