Numerical investigation of the effect of cannula placement on thrombosis

Despite the rapid advancement of left ventricular assist devices (LVADs), adverse events leading to deaths have been frequently reported in patients implanted with LVADs, including bleeding, infection, thromboembolism, neurological dysfunction and hemolysis.Cannulation forms an important component with regards to thrombus formation in assisted patients by varying the intraventricular flow distribution in the left ventricle (LV). To investigate the correlation between LVAD cannula placement and potential for thrombus formation, detailed analysis of the intraventricular flow field was carried out in the present study using a two way fluid structure interaction (FSI), axisymmetric model of a passive LV incorporating an inflow cannula. Three different cannula placements were simulated, with device insertion near the LV apex, penetrating one-fourth and mid-way into the LV long axis. The risk of thrombus formation is assessed by analyzing the intraventricular vorticity distribution and its associated vortex intensity, amount of stagnation flow in the ventricle as well as the level of wall shear stress. Our results show that the one-fourth placement of the cannula into the LV achieves the best performance in reducing the risk of thrombus formation. Compared to cannula placement near the apex, higher vortex intensity is achieved at the one-fourth placement, thus increasing wash out of platelets at the ventricular wall. One-fourth LV penetration produced negligible stagnation flow region near the apical wall region, helping to reduce platelet deposition on the surface of the cannula and the ventricular wall.

[1]  Seiichi Sudo,et al.  Analysis of flow within a left ventricle model fully assisted with continuous flow through the aortic valve. , 2012, Artificial organs.

[2]  Steven Deutsch,et al.  Flow Field Study Comparing Design Iterations of a 50 cc Left Ventricular Assist Device , 2011, ASAIO journal.

[3]  O. Schenk,et al.  ON FAST FACTORIZATION PIVOTING METHODS FOR SPARSE SYMMETRI C INDEFINITE SYSTEMS , 2006 .

[4]  J. Antaki,et al.  In Vitro Evaluation of Ventricular Cannulation for Rotodynamic Cardiac Assist Devices , 2011, Cardiovascular engineering and technology.

[5]  Tao Zhang,et al.  Computational Fluid Dynamics Analysis of Thrombosis Potential in Left Ventricular Assist Device Drainage Cannulae , 2010, ASAIO journal.

[6]  T. J. Dennis,et al.  An improved left ventricular cannula for chronic dynamic blood pump support. , 1995, Artificial organs.

[7]  Shmuel Einav,et al.  Dynamics of Blood Flow and Platelet Transport in Pathological Vessels , 2004, Annals of the New York Academy of Sciences.

[8]  R. Hebbel,et al.  Activation of endothelial and coagulation systems in left ventricular assist device recipients. , 2009, The Annals of thoracic surgery.

[9]  Arash Kheradvar,et al.  Vortex Formation in the Cardiovascular System , 2012 .

[10]  P. Verdonck,et al.  Computer simulation of intraventricular flow and pressure gradients during diastole. , 2000, Journal of biomechanical engineering.

[11]  Karan P. Singh,et al.  Theoretical Biology and Medical Modelling , 2007 .

[12]  Mehdi Behbahani,et al.  A review of computational fluid dynamics analysis of blood pumps , 2009, European Journal of Applied Mathematics.

[13]  Shengshou Hu,et al.  [Numerical simulation of LVAD inflow cannulas with different tips]. , 2012, Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi.

[14]  Cyrus K. Aidun,et al.  Numerical Investigation of the Effects of Channel Geometry on Platelet Activation and Blood Damage , 2011, Annals of Biomedical Engineering.

[15]  F. N. van de Vosse,et al.  Influence of dilated cardiomyopathy and a left ventricular assist device on vortex dynamics in the left ventricle , 2008, Computer methods in biomechanics and biomedical engineering.

[16]  J. O'brien,et al.  Shear-induced platelet aggregation , 1990, The Lancet.

[17]  I. LeGrice,et al.  Shear properties of passive ventricular myocardium. , 2002, American journal of physiology. Heart and circulatory physiology.

[18]  Danny Bluestein,et al.  Flow-induced platelet activation and damage accumulation in a mechanical heart valve: numerical studies. , 2007, Artificial organs.

[19]  Gianni Pedrizzetti,et al.  Model and influence of mitral valve opening during the left ventricular filling. , 2003, Journal of biomechanics.

[20]  Olaf Schenk,et al.  Solving unsymmetric sparse systems of linear equations with PARDISO , 2002, Future Gener. Comput. Syst..

[21]  Ranjit John,et al.  Bleeding and Thrombosis in Patients With Continuous-Flow Ventricular Assist Devices , 2012, Circulation.

[22]  D. Stallknecht FACT SHEET , 2006 .

[23]  F. Tovar,et al.  Structural Performance and Hydrodynamic Resistance of a New Silicone Auricular Cannula Tip , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[24]  H. Oertel,et al.  Fluid-Structure Coupled CFD Simulation of the Left Ventricular Flow During Filling Phase , 2005, Annals of Biomedical Engineering.

[25]  Gino Gerosa,et al.  Influence of inflow cannula length in axial-flow pumps on neurologic adverse event rate: results from a multi-center analysis. , 2008, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[26]  T. Böhlke,et al.  Partitioned Fluid–Solid Coupling for Cardiovascular Blood Flow , 2010, Annals of Biomedical Engineering.

[27]  S. Homma,et al.  Left ventricular mobile thrombus associated with ventricular assist device: diagnosis by transesophageal echocardiography. , 2004, Circulation journal : official journal of the Japanese Circulation Society.

[28]  D. Meyer,et al.  An Overview of Approved and Investigational Left Ventricular Assist Devices , 2004, Proceedings.

[29]  David Nordsletten,et al.  Modelling left ventricular function under assist device support , 2011 .

[30]  Darius G Nabavi,et al.  High level of cerebral microembolization in patients supported with the DeBakey left ventricular assist device. , 2005, The Journal of thoracic and cardiovascular surgery.

[31]  Ulrich Steinseifer,et al.  Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch. , 2010, Artificial organs.