Universal temperature-dependent normalized optoacoustic response of blood

We found and interpreted the universal temperature-dependent optoacoustic (photoacoustic) response (ThOR) in blood; the normalized ThOR is invariant with respect to hematocrit at the hemoglobin’s isosbestic point. The unique compartmentalization of hemoglobin, the primary optical absorber at 805 nm, inside red blood cells (RBCs) explains the effect. We studied the temperature dependence of Gruneisen parameter in blood and aqueous solutions of hemoglobin and for the first time experimentally observed transition through the zero optoacoustic response at temperature T0, which was proved to be consistent for various blood samples. On the other hand, the hemoglobin solutions demonstrated linear concentration function of the temperature T0. When this function was extrapolated to the average hemoglobin concentration inside erythrocytes, the temperature T0 was found equivalent to that measured in whole and diluted blood. The obtained universal curve of blood ThOR was validated in both transparent and light scattering media. The discovered universal optoacoustic temperature dependent blood response provides foundation for future development of non-invasive in vivo temperature monitoring in vascularized tissues and blood vessels.

[1]  V. A. Serebryakov,et al.  Real-time optoacoustic monitoring of the temperature of the retina during laser therapy , 2014 .

[2]  Lihong V Wang,et al.  Photoacoustic thermography of tissue , 2014, Journal of biomedical optics.

[3]  Alexander A Oraevsky,et al.  Red blood cell as a universal optoacoustic sensor for non-invasive temperature monitoring. , 2014, Applied physics letters.

[4]  A. Zhmakin,et al.  Fundamentals of cryobiology , 2008 .

[5]  Alexander Baade,et al.  Real-time temperature determination during retinal photocoagulation on patients. , 2012, Journal of biomedical optics.

[6]  Lihong V. Wang,et al.  Thermoacoustic and photoacoustic sensing of temperature. , 2009, Journal of biomedical optics.

[7]  Richard Su,et al.  Using optoacoustic imaging for measuring the temperature dependence of Grüneisen parameter in optically absorbing solutions. , 2013, Optics express.

[8]  Richard Su,et al.  Temperature dependence of Grüneisen parameter in optically absorbing solutions measured by 2D optoacoustic imaging , 2014, Photonics West - Biomedical Optics.

[9]  S. Emelianov,et al.  Photoacoustic imaging and temperature measurement for photothermal cancer therapy. , 2008, Journal of biomedical optics.

[10]  K. Dill,et al.  Molecular driving forces , 2002 .

[11]  Stanislav Emelianov,et al.  Sensitivity enhanced nanothermal sensors for photoacoustic temperature mapping , 2013, Journal of biophotonics.

[12]  N. Gershfeld,et al.  Thermal instability of red blood cell membrane bilayers: Temperature dependence of hemolysis , 2005, The Journal of Membrane Biology.

[13]  I. Pelivanov,et al.  Temperature dependence of the optoacoustic transformation efficiency in ex vivo tissues for application in monitoring thermal therapies. , 2012, Journal of biomedical optics.

[14]  T van Doorn,et al.  Optical transmission properties of homogenised milk used as a phantom material in visible wavelength imaging. , 1995, Australasian physical & engineering sciences in medicine.

[15]  Richard Su,et al.  Image processing and analysis in a dual-modality optoacoustic/ultrasonic system for breast cancer diagnosis , 2011, BiOS.

[16]  Kirill V. Larin,et al.  Real-time optoacoustic monitoring of temperature in tissues , 1999, Photonics West - Biomedical Optics.