Full-scale performance evaluation of tall buildings under wind

Abstract Full-scale monitoring is an important tool to evaluate the performance of dynamically sensitive structures and assure that the design assumptions and methodologies used to predict their responses yield accelerations that are consistent with in-situ behaviors. Unfortunately, such sustained monitoring is not a common practice for tall buildings, prompting the establishment of the Chicago Full-Scale Monitoring Program (CFSMP), which has spent a decade monitoring three tall buildings embodying structural systems common to high-rise design. This paper presents a cross section of this database for the two-fold purpose of evaluating the in-situ dynamic properties and comparing them to design values and then using these properties to predict RMS accelerations' levels based on wind tunnel test data to evaluate their consistency with full-scale observations. Although the responses observed are low amplitude in nature, some important observations can be made, including the range of wind speeds for which RMS accelerations are more accurately predicted and that conservatism in these predictions is achieved more consistently for the concrete building in the program. This paper also provides further evidence to demonstrate the dependence of critical damping ratios on the structural system employed, the amplitude sensitivity of dynamic properties, and the types of systems for which dynamic properties are more accurately predicted.

[1]  A. P. Jeary,et al.  The effect of amplitude-dependent damping on wind-induced vibrations of a super tall building , 2003 .

[2]  Ahsan Kareem,et al.  Validating wind-induced response of tall buildings : Synopsis of the chicago full-scale monitoring program , 2006 .

[3]  J. Bendat,et al.  Random Data: Analysis and Measurement Procedures , 1971 .

[4]  E. Vanmarcke Properties of Spectral Moments with Applications to Random Vibration , 1972 .

[5]  Tracy Kijewski-Correa,et al.  Dynamic behavior of tall buildings under wind: insights from full‐scale monitoring , 2007 .

[6]  T. Kijewski-Correa,et al.  Monitoring the wind-induced response of tall buildings: GPS performance and the issue of multipath effects , 2007 .

[7]  Kenny C. S Kwok,et al.  Frequency Dependence of Human Response to Wind-Induced Building Motion , 2006 .

[8]  Tracy Kijewski-Correa,et al.  Full-Scale Verification of Dynamic Properties from Short Duration Records , 2007 .

[9]  A. P. Jeary,et al.  Field measurements of wind effects on the tallest building in Hong Kong , 2003 .

[10]  Sergio Lagomarsino,et al.  Forecast models for damping and vibration periods of buildings , 1993 .

[11]  Audrey Bentz,et al.  Wind-Induced Vibrations of Tall Buildings: The Role of Full-Scale Observations in Better Quantifying Habitability , 2009 .

[12]  Yiqing Xiao,et al.  Field measurements of typhoon effects on a super tall building , 2004 .

[13]  Skidmore Title : Full-Scale Validation of Finite Element Models for Tall Buildings , 2022 .

[14]  Qiusheng Li,et al.  Full-scale monitoring of typhoon effects on super tall buildings , 2005 .

[15]  M. Brenner Non-stationary dynamics data analysis with wavelet-SVD filtering , 2003 .

[16]  Ahsan Kareem,et al.  Wavelet Transforms for System Identification in Civil Engineering , 2003 .

[17]  A. Kareem,et al.  On the Wind-Induced Response of Tall Buildings : The Effect of Uncertainties in Dynamic Properties and Human Comfort Thresholds , 2005 .

[18]  Ahsan Kareem,et al.  Full-Scale Validation of Wind-Induced Response of Tall Buildings: Investigation of Amplitude-Dependent Dynamic Properties , 2007 .

[19]  Yukio Tamura,et al.  Damping Evaluation Using Full-Scale Data of Buildings in Japan , 2003 .

[20]  Ahsan Kareem,et al.  On the reliability of a class of system identification techniques: insights from bootstrap theory , 2002 .

[21]  Rachel Elizabeth Bashor,et al.  Dynamics of wind sensitive structures , 2011 .

[22]  Bradley S. Young,et al.  Finite Element Modeling of Common Lateral Systems in Tall Buildings: Insights from Full-Scale Monitoring , 2010 .

[23]  Ahsan Kareem,et al.  Damping in structures: its evaluation and treatment of uncertainty , 1996 .

[24]  T. Mexia,et al.  Author ' s personal copy , 2009 .

[25]  Tracy Kijewski-Correa,et al.  Predictive Models for Damping in Buildings: The Role of Structural System Characteristics , 2008 .

[26]  Eylem Bütüner,et al.  A MASTER'S THESIS , 2003 .

[27]  James David Pirnia Full-Scale Dynamic Characteristics of Tall Buildings and Impacts on Occupant Comfort , 2009 .

[28]  You-Lin Xu,et al.  Modal identification of Di Wang Building under Typhoon York using the Hilbert–Huang transform method , 2003 .