Precision of implant placement with stereolithographic templates: a pilot in vitro study.

This pilot study assesses the accuracy of 2 bone-supported stereolithographic surgical templates with respect to placement of implants in originally planned positions, and it tests the precision of dental volumetric tomography planning. Two mandibles retrieved from formalin-fixed human cadavers were scanned by dental volumetric tomography for planning of the implant positions, leading to stereolithographic models and fabrication of surgical guides. The situation immediately following drilling and implant insertion by an experienced surgeon was scanned and the outcome compared with the initial planning. The 3-dimensional discrepancies were then analyzed and determined. The results show deviations of the placed implants from the original planning, especially in the vertical direction, making the seating of a prefabricated denture impossible. At present, the flapless surgery technique based on stereolithographic surgical templates appears unsafe; further improvement is required.

[1]  Abbas Azari,et al.  Flapless implant surgery: review of the literature and report of 2 cases with computer-guided surgical approach. , 2008, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[2]  Ilser Turkyilmaz,et al.  Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants. , 2008, Journal of periodontology.

[3]  Gerlig Widmann,et al.  Flapless implant surgery in the edentulous jaw based on three fixed intraoral reference points and image-guided surgical templates: accuracy in human cadavers. , 2010, Clinical oral implants research.

[4]  Scott D Ganz,et al.  Use of stereolithographic models as diagnostic and restorative aids for predictable immediate loading of implants. , 2003, Practical procedures & aesthetic dentistry : PPAD.

[5]  S. Rosenstiel,et al.  Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement. , 2009, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[6]  Rikard Söderberg,et al.  Accuracy of CAD/CAM-guided surgical template implant surgery on human cadavers: Part I. , 2010, The Journal of prosthetic dentistry.

[7]  M. Zwahlen,et al.  A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry. , 2009, Clinical oral implants research.

[8]  I. Tekdemir,et al.  Fresh-frozen vs. embalmed bone: is it possible to use formalin-fixed human bone for biomechanical experiments on implants? , 2009, Clinical oral implants research.

[9]  Jean Loup Coudert,et al.  An image-guided system-drilled surgical template and trephine guide pin to make treatment of completely edentulous patients easier: a clinical report on immediate loading. , 2004, Clinical implant dentistry and related research.

[10]  Alan L Rosenfeld,et al.  Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 2: rapid-prototype medical modeling and stereolithographic drilling guides requiring bone exposure. , 2006, The International journal of periodontics & restorative dentistry.

[11]  Patricia R Cury,et al.  Clinical application of stereolithographic surgical guides for implant placement: preliminary results. , 2005, Journal of periodontology.

[12]  N. Otsuka,et al.  The effect of freezing and intraosseous fluid on the stiffness behavior of canine trabecular bone. , 2001, Orthopedics.

[13]  Volkan Arısan,et al.  Accuracy of two stereolithographic guide systems for computer-aided implant placement: a computed tomography-based clinical comparative study. , 2010, Journal of periodontology.

[14]  Herman K Kupeyan,et al.  Definitive CAD/CAM-guided prosthesis for immediate loading of bone-grafted maxilla: a case report. , 2006, Clinical implant dentistry and related research.

[15]  O. Ozan,et al.  The use of a computerized tomography-based software program with a flapless surgical technique in implant dentistry: a case report. , 2009, The International journal of oral & maxillofacial implants.

[16]  R Jacobs,et al.  The use of CT scan based planning for oral rehabilitation by means of implants and its transfer to the surgical field: a critical review on accuracy. , 2008, Journal of oral rehabilitation.

[17]  Nadine Brodala,et al.  Flapless surgery and its effect on dental implant outcomes. , 2009, The International journal of oral & maxillofacial implants.

[18]  Paul Suetens,et al.  A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report. , 2002, The International journal of oral & maxillofacial implants.

[19]  F. Forriol,et al.  Effects of preservation on the mechanical strength and chemical composition of cortical bone: an experimental study in sheep femora. , 2002, Biomaterials.

[20]  K. Rungcharassaeng,et al.  Computer-guided immediate provisionalization of anterior multiple adjacent implants: surgical and prosthodontic rationale. , 2006, Practical procedures & aesthetic dentistry : PPAD.

[21]  Kevin C Kopp,et al.  Predictable implant placement with a diagnostic/surgical template and advanced radiographic imaging. , 2003, The Journal of prosthetic dentistry.

[22]  Guy Marchal,et al.  Multimodality image registration by maximization of mutual information , 1997, IEEE Transactions on Medical Imaging.

[23]  Saad A Al-Harbi,et al.  Implant Placement Accuracy When Using Stereolithographic Template as a Surgical Guide: Preliminary Results , 2009, Implant dentistry.

[24]  M. Bloching,et al.  Retrospective analysis of titanium plate-retained prostheses placed after total rhinectomy. , 2009, The International journal of oral & maxillofacial implants.

[25]  Predrag Sukovic,et al.  Accuracy of implant placement with a stereolithographic surgical guide. , 2003, The International journal of oral & maxillofacial implants.

[26]  Christopher B Marchack,et al.  The use of a custom template for immediate loading with the definitive prosthesis: a clinical report. , 2003, Journal of the California Dental Association.

[27]  M Naitoh,et al.  Can implants be correctly angulated based on surgical templates used for osseointegrated dental implants? , 2000, Clinical oral implants research.

[28]  C. Goodacre,et al.  Misfit of implant fixed complete denture following computer-guided surgery. , 2009, The International journal of oral & maxillofacial implants.

[29]  Steven D Sudbrink Computer-guided implant placement with immediate provisionalization: a case report. , 2005, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[30]  Filip Schutyser,et al.  A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study. , 2005, Clinical implant dentistry and related research.

[31]  Gerlig Widmann,et al.  Accuracy in computer-aided implant surgery--a review. , 2006, The International journal of oral & maxillofacial implants.

[32]  R. Diecidue,et al.  Trigeminal nerve injuries after mandibular implant placement--practical knowledge for clinicians. , 2006, The International journal of oral & maxillofacial implants.

[33]  S. Balshi,et al.  Surgical planning and prosthesis construction using computer technology and medical imaging for immediate loading of implants in the pterygomaxillary region. , 2006, The International journal of periodontics & restorative dentistry.

[34]  R Jacobs,et al.  Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study. , 2007, Journal of clinical periodontology.