Biomechanical Analysis of Anterior Instrumentation for Lumbar Corpectomy

Study Design. In vitro biomechanical assessment of spinal stability after corpectomy reconstruction. Objectives. To gain a more thorough understanding of the biomechanical properties of anterior plate versus dual rod systems used for anterior lumbar corpectomy reconstruction. Summary of Background Data. Vertebral corpectomy is commonly required in the treatment of several types of spinal pathology (fracture, tumor, infection). Stabilization with strut allograft and anterior instrumentation can be accomplished with one of several anterior implant systems. These include plate systems and rod-based systems with theoretically different structural properties. Methods. Two instrumentation systems, the ATL Z-plate and the Antares system, were each applied to 10 calf lumbar spines with a cortical strut graft reconstructing an L3 corpectomy defect. All spines were tested biomechanically to determine construct stiffness under physiologic loads in multiple planes and then tested in torsion to failure. Results. There was greater stiffness (P < 0.05) in all directions of bending (flexion, extension, lateral bending) for the Antares dual rod construct compared to the Z-plate constructs. No significant difference was noted in either torsional testing under physiologic loads or torque to failure between the groups. Conclusions. Although there was significantly greater resistance to bending with the dual rod construct, the ultimate selection of a system will require an individual analysis of implant profile, construct demand, and ease of use. Both systems provided secure initial fixation following lumbar corpectomy; however, the Antares system may increase the likelihood of graft incorporation in cases with greater instability and higher load demands.

[1]  J. M. Wattenbarger,et al.  Mechanical testing of a single rod versus a double rod in a long-segment animal model. , 2001, Journal of spinal disorders.

[2]  V K Goel,et al.  In vitro biomechanical analysis of three anterior thoracolumbar implants. , 2000, Journal of neurosurgery.

[3]  F. Farley,et al.  Torsional stiffness of a single-rod construct using three instrumentation systems for thoracic scoliosis. , 1999, Journal of spinal disorders.

[4]  B. Cunningham,et al.  Static and fatigue biomechanical properties of anterior thoracolumbar instrumentation systems. A synthetic testing model. , 1999, Spine.

[5]  J. Torner,et al.  Biomechanical studies on two anterior thoracolumbar implants in cadaveric spines. , 1999, Spine.

[6]  L. Claes,et al.  Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants , 1998, European Spine Journal.

[7]  D. Kunz,et al.  Anterior Instrumentation of the Thoracolumbar Spine: A Biomechanical Comparison , 1997, Spine.

[8]  L. Claes,et al.  Biomechanical comparison of calf and human spines. , 1996, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[9]  L. Lenke,et al.  Anterior Fresh Frozen Structural Allografts in the Thoracic and Lumbar Spine: Do They Work If Combined With Posterior Fusion and Instrumentation in Adult Patients With Kyphosis or Anterior Column Defects? , 1995, Spine.

[10]  M. Asher,et al.  The Effects of Implant Stiffness on the Bypassed Bone Mineral Density and Facet Fusion Stiffness of the Canine Spine , 1994, Spine.

[11]  J. Cordey,et al.  A Paradigm of Delayed Union and Nonunion in the Lumbosacral Joint: A Study of Motion and Bone Grafting of the Lumbosacral Spine in Sheep , 1991, Spine.

[12]  P. McAfee,et al.  Anterior spinal fixation after lumbar corpectomy. A study in dogs. , 1991, The Journal of bone and joint surgery. American volume.

[13]  R B Ashman,et al.  Effect of Spinal Construct Stiffness on Early Fusion Mass Incorporation Experimental Study , 1990, Spine.

[14]  J. Kostuik,et al.  Evaluation of Surgical Treatment for Burst Fractures , 1990, Spine.

[15]  W. Edwards,et al.  In vitro spinal arthrodesis implant mechanical testing protocols. , 1989, Journal of spinal disorders.

[16]  P. McAfee,et al.  Biomechanical analysis of anterior and posterior instrumentation systems after corpectomy. A calf-spine model. , 1988, The Journal of bone and joint surgery. American volume.

[17]  K. Harrington Anterior decompression and stabilization of the spine as a treatment for vertebral collapse and spinal cord compression from metastatic malignancy. , 1988, Clinical orthopaedics and related research.

[18]  A. Hodgson,et al.  Anterior spinal fusion a preliminary communication on the radical treatment of pott's disease and pott's paraplegia , 1956, The British journal of surgery.