Experimental Study on Glaze Icing Detection of 110 kV Composite Insulators Using Fiber Bragg Gratings

Icing detection of composite insulators is essential for the security and stability of power grids. As conventional methods have met difficulties in harsh weather, a 110 kV composite insulator with embedded Fiber Bragg Gratings (FBGs) was proposed for detecting glaze icing in this paper. FBG temperature compensation sensors in ceramic tubes were adopted for simultaneous measurement of icicle loads and temperature. Then, temperature calibration experiments and simulated icicle load experiments were carried out to obtain temperature and icicle load characteristics of FBGs. The results showed that temperature sensitivities of FBG strain sensors and FBG temperature compensation sensors were 18.16 pm/°C, and 13.18 pm/°C, respectively. Besides, wavelength shifts were linearly related to icicle loads within the polar angle range of −60° to 60°, and the load coefficient of FBG facing the icicle was -34.6 pm/N. In addition, the wavelength shift generated by several icicles was equal to the sum of wavelength shifts generated by each icicle within the polar angle range of −15° to 15°. Finally, icicles can cause wavelength shifts of FBGs within a big shed spacing. The paper provides a novel icing detection technology for composite insulators in transmission lines.

[1]  Jie Wei,et al.  Detection of Glaze Icing Load and Temperature of Composite Insulators Using Fiber Bragg Grating , 2019, Sensors.

[2]  G. G. Portnov,et al.  Analysis of stress concentration during tension of round pultruded composite rods , 2008 .

[3]  Piotr Kacejko,et al.  Overhead Transmission Line Sag Estimation Using a Simple Optomechanical System with Chirped Fiber Bragg Gratings. Part 1: Preliminary Measurements , 2018, Sensors.

[4]  Bo Zhang,et al.  A Fiber Bragg Grating-Based Dynamic Tension Detection System for Overhead Transmission Line Galloping , 2018, Sensors.

[5]  Guo-Ming Ma,et al.  Distributed Partial Discharge Detection in a Power Transformer Based on Phase-Shifted FBG , 2018, IEEE Sensors Journal.

[6]  Deng He-ming Discuss on the Intelligent Monitoring Technology of Composite Insulator with the Optic Fiber Sensors , 2011 .

[7]  M. Farzaneh,et al.  Three-dimensional modeling of potential and electric-field distributions along an EHV ceramic post insulator covered with ice-Part II: effect of air gaps and partial arcs , 2005, IEEE Transactions on Power Delivery.

[8]  Tong Sun,et al.  Strain Measurement Using Embedded Fiber Bragg Grating Sensors Inside an Anchored Carbon Fiber Polymer Reinforcement Prestressing Rod for Structural Monitoring , 2009, IEEE Sensors Journal.

[9]  Cao Mi Study on the Application of Optical Sensor in Composite Insulator , 2014 .

[10]  K. Hill,et al.  Fiber Bragg grating technology fundamentals and overview , 1997 .

[11]  Zhehao Yan,et al.  Insulator string leakage current-monitoring sensor based on fiber Bragg grating. , 2018, Optics express.

[12]  Jun Zhou,et al.  Ice flashover performance and its characterization parameter of composite insulator with booster sheds , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[13]  H. Farhangi,et al.  The path of the smart grid , 2010, IEEE Power and Energy Magazine.

[14]  Maciej Kumosa,et al.  Analyses of composite insulators with crimped end-fittings: Part I—non linear finite element computations , 2002 .

[15]  Fan Yang,et al.  Theoretical analysis of temperature response of the fiber Bragg grating embedded in composite insulator , 2016, Other Conferences.

[16]  Jubai An,et al.  A Texture Segmentation Algorithm Based on PCA and Global Minimization Active Contour Model for Aerial Insulator Images , 2012, IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing.

[17]  M. Farzaneh,et al.  Three-dimensional modeling of potential and electric-field distributions along an EHV ceramic post insulator covered with ice - Part I: Simulations of a melting period , 2005, IEEE Transactions on Power Delivery.

[18]  Liu Gui-fu Influence of Environment Parameters on the Icing Accretion on the Surface of Insulator , 2010 .

[19]  M. Farzaneh,et al.  Study of discharge in air from the tip of an icicle , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[20]  Emma Marris,et al.  Energy: Upgrading the grid , 2008, Nature.

[21]  Ming Tang,et al.  Monitoring on internal temperature of composite insulator with embedding fiber Bragg grating for early diagnosis , 2017, 2017 25th Optical Fiber Sensors Conference (OFS).

[22]  Xiong Peng Production and Calibration Test of the Composite Insulator with Fiber Bragg Grating Embedded , 2012 .

[23]  L Bjerkan Application of fiber-optic bragg grating sensors in monitoring environmental loads of overhead power transmission lines. , 2000, Applied optics.

[24]  WAN Xiao-dong,et al.  On-line Monitoring Technology of UHV Composite Insulator Based on FBG Sensor , 2019, 2019 IEEE Sustainable Power and Energy Conference (iSPEC).

[25]  Hao Jiang,et al.  Analysis of icicle growth process of composite insulator under energized condition and its impact factors , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[26]  Fei Zhang,et al.  An Online Technology for Measuring Icing Shape on Conductor Based on Vision and Force Sensors , 2017, IEEE Transactions on Instrumentation and Measurement.

[27]  Heming Deng,et al.  The feasibility of the composite insulator with fiber Bragg grating embedded in the rod , 2014, IEEE PES Innovative Smart Grid Technologies, Europe.

[28]  Xiong Peng Stress Distribution Analyses of Composite Insulator with Fiber Bragg Grating Embedded , 2011 .

[29]  Xiong Peng Fault Simulation Experiment on Composite Insulators with Fiber Bragg Grating Implanted , 2013 .

[30]  Xiong Peng Practical Researches on Achieving Status Monitoring with the Use of Optic Fiber Composite Insulator , 2010 .

[31]  Gevork B. Gharehpetian,et al.  Partial discharge acoustic emission detector using mandrel-connected fiber Bragg grating sensor , 2018, Optical Engineering.

[32]  Alain Trouillet,et al.  Integration of fibre Bragg grating strain sensors into composite electrical insulators , 2004, European Workshop on Optical Fibre Sensors.

[33]  Lin Yang,et al.  Icing Condition Assessment of In-Service Glass Insulators Based on Graphical Shed Spacing and Graphical Shed Overhang , 2018 .

[34]  Jubai An,et al.  A Robust Insulator Detection Algorithm Based on Local Features and Spatial Orders for Aerial Images , 2015, IEEE Geoscience and Remote Sensing Letters.

[35]  Maciej Kumosa,et al.  ANALYSES OF COMPOSITE INSULATORS WITH CRIMPED END- FITTINGS: PART II - SUITABLE CRIMPING CONDITIONS , 2002 .