A Method for 3D Histopathology Reconstruction Supporting Mouse Microvasculature Analysis

Structural abnormalities of the microvasculature can impair perfusion and function. Conventional histology provides good spatial resolution with which to evaluate the microvascular structure but affords no 3-dimensional information; this limitation could lead to misinterpretations of the complex microvessel network in health and disease. The objective of this study was to develop and evaluate an accurate, fully automated 3D histology reconstruction method to visualize the arterioles and venules within the mouse hind-limb. Sections of the tibialis anterior muscle from C57BL/J6 mice (both normal and subjected to femoral artery excision) were reconstructed using pairwise rigid and affine registrations of 5 µm-thick, paraffin-embedded serial sections digitized at 0.25 µm/pixel. Low-resolution intensity-based rigid registration was used to initialize the nucleus landmark-based registration, and conventional high-resolution intensity-based registration method. The affine nucleus landmark-based registration was developed in this work and was compared to the conventional affine high-resolution intensity-based registration method. Target registration errors were measured between adjacent tissue sections (pairwise error), as well as with respect to a 3D reference reconstruction (accumulated error, to capture propagation of error through the stack of sections). Accumulated error measures were lower (p<0.01) for the nucleus landmark technique and superior vasculature continuity was observed. These findings indicate that registration based on automatic extraction and correspondence of small, homologous landmarks may support accurate 3D histology reconstruction. This technique avoids the otherwise problematic “banana-into-cylinder” effect observed using conventional methods that optimize the pairwise alignment of salient structures, forcing them to be section-orthogonal. This approach will provide a valuable tool for high-accuracy 3D histology tissue reconstructions for analysis of diseased microvasculature.

[1]  Arrate Muñoz-Barrutia,et al.  3D reconstruction of histological sections: Application to mammary gland tissue , 2010, Microscopy research and technique.

[2]  E. Eriksson,et al.  Microvascular dimensions and blood flow in skeletal muscle. , 1972, Acta physiologica Scandinavica.

[3]  Horst Karl Hahn,et al.  Registration of histological whole slide images guided by vessel structures , 2013, Journal of pathology informatics.

[4]  C. Ellis,et al.  Fibroblast growth factor 9 delivery during angiogenesis produces durable, vasoresponsive microvessels wrapped by smooth muscle cells , 2011, Nature Biotechnology.

[5]  F. Pfeiffer,et al.  Translation of Atherosclerotic Plaque Phase-Contrast CT Imaging from Synchrotron Radiation to a Conventional Lab-Based X-Ray Source , 2013, PloS one.

[6]  Sébastien Ourselin,et al.  Reconstructing a 3D structure from serial histological sections , 2001, Image Vis. Comput..

[7]  M. Gleeson,et al.  Scott-Brown's otorhinolaryngology, head and neck surgery , 2008 .

[8]  Yves-Rémi Van Eycke,et al.  Registration of whole immunohistochemical slide images: an efficient way to characterize biomarker colocalization , 2015, J. Am. Medical Informatics Assoc..

[9]  Pieter Wesseling,et al.  Three-dimensional (3D) reconstruction and quantitative analysis of the microvasculature in medulloblastoma and ependymoma subtypes , 2006, Angiogenesis.

[10]  Aaron Fenster,et al.  3D prostate histology reconstruction: an evaluation of image-based and fiducial-based algorithms , 2013, Medical Imaging.

[11]  J. Janáček,et al.  The branching pattern of villous capillaries and structural changes of placental terminal villi in type 1 diabetes mellitus. , 2012, Placenta.

[12]  Thomas P. Ryan,et al.  Modern Engineering Statistics , 2007 .

[13]  Li Bai,et al.  Smoothness-guided 3-D reconstruction of 2-D histological images , 2011, NeuroImage.

[14]  Birte Steiniger,et al.  The Open Microcirculation in Human Spleens , 2011, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[15]  Nassir Navab,et al.  Reconstruction of 3-D Histology Images by Simultaneous Deformable Registration , 2011, MICCAI.

[16]  P. Wesseling,et al.  Three-dimensional reconstruction of tumor microvasculature: Simultaneous visualization of multiple components in paraffin-embedded tissue , 2006, Angiogenesis.

[17]  Aaron Fenster,et al.  Prostate: registration of digital histopathologic images to in vivo MR images acquired by using endorectal receive coil. , 2012, Radiology.

[18]  W. Young,et al.  Cerebrovascular Casting of the Adult Mouse for 3D Imaging and Morphological Analysis , 2011, Journal of visualized experiments : JoVE.

[19]  J. Snow,et al.  Otorhinolaryngology : head and neck surgery , 1996 .

[20]  L. V. Valen,et al.  Human Anatomy , 1899, Nature.

[21]  Joachim Hornegger,et al.  Landmark-constrained 3-D Histological Imaging: A Morphology-preserving Approach , 2011, VMV.

[22]  Darren Treanor,et al.  Toward routine use of 3D histopathology as a research tool. , 2012, The American journal of pathology.

[23]  M. Humbert,et al.  Pathologic assessment of vasculopathies in pulmonary hypertension. , 2004, Journal of the American College of Cardiology.

[24]  Milan Sonka,et al.  3D Slicer as an image computing platform for the Quantitative Imaging Network. , 2012, Magnetic resonance imaging.

[25]  A. Fenster,et al.  Registration of prostate histology images to ex vivo MR images via strand‐shaped fiducials , 2012, Journal of magnetic resonance imaging : JMRI.

[26]  Rémy Prost,et al.  Robust Alignment of Prostate Histology Slices With Quantified Accuracy , 2013, IEEE Transactions on Biomedical Engineering.

[27]  Derek R. Magee,et al.  3D reconstruction of multiple stained histology images , 2013, Journal of pathology informatics.

[28]  J. Pickering,et al.  Pre–B-Cell Colony–Enhancing Factor Regulates NAD+-Dependent Protein Deacetylase Activity and Promotes Vascular Smooth Muscle Cell Maturation , 2005, Circulation research.

[29]  T. Kurose,et al.  The skeletal muscle vascular supply closely correlates with the muscle fiber surface area in the rat. , 2008, Archives of histology and cytology.

[30]  Christian Nøhr,et al.  Comparing Approaches to Measuring the Adoption and Usability of Electronic Health Records: Lessons Learned from Canada, Denmark and Finland , 2013, MedInfo.

[31]  J. Janáček,et al.  A novel method for evaluation of capillarity in human skeletal muscles from confocal 3D images. , 2011, Microvascular research.

[32]  M J Campbell,et al.  Statistics in Medicine: Calculating confidence intervals for some non-parametric analyses , 1988 .

[33]  Michael J Ackerman,et al.  Engineering and algorithm design for an image processing Api: a technical report on ITK--the Insight Toolkit. , 2002, Studies in health technology and informatics.

[34]  M. McCall,et al.  HEAD AND NECK SURGERY , 2006, ORL-head and neck nursing : official journal of the Society of Otorhinolaryngology and Head-Neck Nurses.