The influence of contraction amplitude and firing history on spike‐triggered averaged trapezius motor unit potentials

The spike‐triggered averaged (STA) technique was used to examine trapezius motor unit potentials and their dependence on contraction amplitude and firing history. Individual motor unit firings were identified by a fine‐wire intramuscular electrode, while STA‐derived potentials were extracted from the simultaneously recorded surface electromyographic (SEMG) signal. Amplitude‐controlled contractions and contractions with typing tasks and mental stress were carried out. STA potentials were mostly derived from 20 s intervals of firing. Motor unit synchrony was estimated by peristimulus time histograms (PSTHs). An association between SEMG amplitude and STA‐derived motor unit potentials was found: motor unit area showed a four‐fold increase when SEMG amplitude increased from 1.5 to 10.5% of the root mean square‐detected SEMG signal at maximal voluntary contraction (%EMGmax). Low‐ and higher threshold motor unit potentials, all with recruitment thresholds <10% EMGmax, had similar area at the same contraction amplitude. A significant increase in the STA‐derived potentials was observed after 3 min of constant‐amplitude contractions; however, this difference was reduced after 10 min and no longer present after 30 min of contraction. Motor unit synchrony accounted for, on average, 2.8% additional firings within 2 ms of the triggering motor unit. We conclude that the increase in STA‐derived potentials with contraction amplitude is, to a major extent, due to motor unit synchrony, limiting the applicability of this method in postural muscles presenting wide motor unit potentials. The similar area of motor units at same SEMG amplitude may indicate that trapezius motor units recruited below 10% EMGmax are of similar size and thus not organized according to the Henneman size principle.

[1]  F. Buchthal,et al.  Multielectrode study of the territory of a motor unit. , 1957, Acta physiologica Scandinavica.

[2]  G. Somjen,et al.  Excitability and inhibitability of motoneurons of different sizes. , 1965, Journal of neurophysiology.

[3]  R B Stein,et al.  The orderly recruitment of human motor units during voluntary isometric contractions , 1973, The Journal of physiology.

[4]  P H Ellaway,et al.  Cumulative sum technique and its application to the analysis of peristimulus time histograms. , 1978, Electroencephalography and clinical neurophysiology.

[5]  P. Kirkwood On the use and interpretation of cross-correlation measurements in the mammalian central nervous system , 1979, Journal of Neuroscience Methods.

[6]  C. D. De Luca,et al.  Behaviour of human motor units in different muscles during linearly varying contractions , 1982, The Journal of physiology.

[7]  D. L. Tuck,et al.  Variations in the time course of the synchronization of intercostal motoneurones in the cat , 1982, The Journal of physiology.

[8]  Ronald S. Lefever,et al.  A Procedure for Decomposing the Myoelectric Signal Into Its Constituent Action Potentials - Part I: Technique, Theory, and Implementation , 1982, IEEE Transactions on Biomedical Engineering.

[9]  B Mambrito,et al.  A technique for the detection, decomposition and analysis of the EMG signal. , 1984, Electroencephalography and clinical neurophysiology.

[10]  R H Westgaard,et al.  Generation of muscle tension additional to postural muscle load. , 1987, Ergonomics.

[11]  A. McComas,et al.  Increased sodium pump activity following repetitive stimulation of rat soleus muscles. , 1989, The Journal of physiology.

[12]  Transient hyperpolarization of non‐contracting muscle fibres in anaesthetized rats. , 1992, The Journal of physiology.

[13]  R H Westgaard,et al.  The effect of motivation on shoulder-muscle tension in attention-demanding tasks. , 1994, Ergonomics.

[14]  A. McComas,et al.  Pseudofacilitation: A misleading term , 1994, Muscle & nerve.

[15]  Brian Tracy,et al.  Decomposition‐enhanced spike‐triggered averaging: Contraction level effects , 1997, Muscle & nerve.

[16]  D. Stegeman,et al.  Motor unit potential contribution to surface electromyography. , 1997, Acta physiologica Scandinavica.

[17]  R H Westgaard,et al.  Motor unit substitution in long-duration contractions of the human trapezius muscle. , 1999, Journal of neurophysiology.

[18]  A. Harrison,et al.  Measurement of force and both surface and deep M wave properties in isolated rat soleus muscles. , 1999, The American journal of physiology.

[19]  Alexander Adam,et al.  Decomposition and Analysis of Intramuscular Electromyographic Signals , 1999 .

[20]  R. Enoka,et al.  Motor-unit synchronization increases EMG amplitude and decreases force steadiness of simulated contractions. , 2000, Journal of neurophysiology.

[21]  G. Sjøgaard,et al.  Motor unit recruitment and rate coding in response to fatiguing shoulder abductions and subsequent recovery , 2000, European Journal of Applied Physiology.

[22]  C J De Luca,et al.  Motor control of low-threshold motor units in the human trapezius muscle. , 2001, Journal of neurophysiology.

[23]  S J Day,et al.  Experimental simulation of cat electromyogram: evidence for algebraic summation of motor-unit action-potential trains. , 2001, Journal of neurophysiology.

[24]  R M Enoka,et al.  Long-term activity in upper- and lower-limb muscles of humans. , 2001, Journal of applied physiology.

[25]  Mikael Forsman,et al.  Low-threshold motor unit activity during a 1-h static contraction in the trapezius muscle , 2002 .

[26]  D. Farina,et al.  Assessment of single motor unit conduction velocity during sustained contractions of the tibialis anterior muscle with advanced spike triggered averaging , 2002, Journal of Neuroscience Methods.

[27]  R. Enoka,et al.  Motor-unit synchronization alters spike-triggered average force in simulated contractions. , 2002, Journal of neurophysiology.

[28]  C. J. Luca,et al.  Motor unit recruitment and derecruitment induced by brief increase in contraction amplitude of the human trapezius muscle , 2003, The Journal of physiology.

[29]  C. Jensen,et al.  The influence of electrode position on bipolar surface electromyogram recordings of the upper trapezius muscle , 2004, European Journal of Applied Physiology and Occupational Physiology.

[30]  Daniel W Stashuk,et al.  Motor unit number estimation by decomposition‐enhanced spike‐triggered averaging: Control data, test–retest reliability, and contractile level effects , 2004, Muscle & nerve.

[31]  P. Mork,et al.  Firing patterns of low-threshold trapezius motor units in feedback-controlled contractions and vocational motor activities , 2004, Experimental Brain Research.

[32]  K. Jørgensen,et al.  The effect of prolonged isometric contractions on muscle fluid balance , 2004, European Journal of Applied Physiology and Occupational Physiology.

[33]  Andrew J Fuglevand,et al.  Distribution of motor unit force in human extensor digitorum assessed by spike-triggered averaging and intraneural microstimulation. , 2004, Journal of neurophysiology.

[34]  R. Enoka,et al.  Influence of amplitude cancellation on the simulated surface electromyogram. , 2005, Journal of applied physiology.