An adaptive single pole autoreclosure based on zero sequence power

In this paper, a novel adaptive single pole autoreclosure is introduced. This reclosure is based on monitoring the fundamental component of the zero sequence instantaneous power to detect the extinction instant of the arc in its secondary period. Thus, adaptive closing instant can be achieved. The concept of reclosure is validated via typical examples of transmission line exposed to ground arcing fault. Effects of fault location and load flow on the accuracy of the technique are examined. Discriminatory zones of the secondary arc period in the zero sequence power domains are determined. A proposed threshold for the reclosing instant is introduced and examined. Validation of the proposed algorithm is verified via Digital Signal Processing (DSP) experimental test set-up. The test results corroborate the efficacy of proposed technique.

[1]  Eugeniusz Rosolowski,et al.  Arc effect on single-phase reclosing time of a UHV power transmission line , 2004 .

[2]  N.I. Elkalashy,et al.  Universal arc representation using EMTP , 2005, IEEE Transactions on Power Delivery.

[3]  A. E. Emanuel,et al.  Practical definitions for powers in systems with nonsinusoidal waveforms and unbalanced loads: a discussion , 1996 .

[4]  A. T. Johns,et al.  Neural-network based adaptive single-pole autoreclosure technique for EHV transmission systems , 1994 .

[5]  Vladimir Terzija,et al.  Long arc in free air: laboratory testing, modelling, simulation and model-parameters estimation , 2002 .

[6]  Vladimir Terzija,et al.  A new approach to the arcing faults detection for fast autoreclosure in transmission systems , 1995 .

[7]  Ying-Hong Lin,et al.  A new PMU-based fault detection/location technique for transmission lines with consideration of arcing fault discrimination-part I: theory and algorithms , 2004 .

[8]  K. J. Cornick,et al.  Power system transients caused by arcing faults , 1981 .

[9]  A. T. Johns,et al.  Improved techniques for modelling fault arcs an faulted EHV transmission systems , 1994 .

[10]  Adly A. Girgis,et al.  Effect of harmonic distortion in reactive power measurement , 1990 .

[11]  A. E. Emanuel Powers in nonsinusoidal situations-a review of definitions and physical meaning , 1990 .

[12]  A. E. Emanuel,et al.  On the definition of power factor and apparent power in unbalanced polyphase circuits with sinusoidal voltage and currents , 1993 .

[13]  P. Schegner,et al.  Impacts of operating conditions and line parameters on secondary arc extinction of single-phase autoreclosures , 2005, 2005 International Conference on Future Power Systems.

[14]  Kouichi Ikeda,et al.  Arc voltage characteristics of high current fault arcs in long gaps , 2000 .

[15]  G. Ban,et al.  Testing EHV secondary arcs , 2001, 2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502).

[16]  Kuniaki Yabe,et al.  Power differential method for discrimination between fault and magnetizing inrush current in transformers , 1996 .

[17]  Y. Ozaki,et al.  Forced extinction characteristics of secondary arc on UHV (1000 kV class) transmission lines , 1993 .

[18]  M. Kizilcay,et al.  Digital simulation of fault arcs in power systems , 2007 .

[19]  A. T. Johns,et al.  Design and implementation of an adapative single pole autoreclosure technique for transmission lines using artificial neural networks , 1996 .