Optical Coherence Tomography for the Diagnosis and Evaluation of Human Otitis Media

We report the application of optical coherence tomography (OCT) to the diagnosis and evaluation of otitis media (OM). Whereas conventional diagnostic modalities for OM, including standard and pneumatic otoscopy, are limited to visualizing the surface of the tympanic membrane (TM), OCT effectively reveals the depth-resolved microstructure below the TM with very high spatial resolution, with the potential advantage of its use for diagnosing different types of OM. We examined the use of 840-nm spectral domain-OCT (SD-OCT) clinically, using normal ears and ears with the adhesive and effusion types of OM. Specific features were identified in two-dimensional OCT images of abnormal TMs, compared to images of healthy TMs. Analysis of the A-scan (axial depth scan) identified unique patterns of constituents within the effusions. The OCT images could not only be used to construct a database for the diagnosis and classification of OM but OCT might also represent an upgrade over current otoscopy techniques. Graphical Abstract

[1]  Zhongping Chen,et al.  Imaging the Internal Structure of the Rat Cochlea Using Optical Coherence Tomography at 0.827 μm and 1.3 μm , 2004 .

[2]  Stephen A. Boppart,et al.  Optical coherence tomography: Principles applications and advances , 2004 .

[3]  Jeehyun Kim,et al.  In vivo imaging of middle-ear and inner-ear microstructures of a mouse guided by SD-OCT combined with a surgical microscope. , 2014, Optics express.

[4]  John S. Oghalai,et al.  In vivo vibrometry inside the apex of the mouse cochlea using spectral domain optical coherence tomography , 2013, Biomedical optics express.

[5]  Jeehyun Kim,et al.  Full-range k-domain linearization in spectral-domain optical coherence tomography. , 2011, Applied optics.

[6]  J. Kobler,et al.  Simultaneous 3D imaging of sound-induced motions of the tympanic membrane and middle ear ossicles , 2013, Hearing Research.

[7]  Evan R. Sprague,et al.  ORCID , 2017, Journal of the Medical Library Association : JMLA.

[8]  Jeehyun Kim,et al.  Handheld Optical Coherence Tomography Scanner for Primary Care Diagnostics , 2011, IEEE Transactions on Biomedical Engineering.

[9]  David Huang,et al.  Handbook of optical coherence tomography. , 2003, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[10]  Marc Rubinstein,et al.  Optical Coherence Tomography of Cholesteatoma , 2010, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[11]  Thomas E. Milner,et al.  Real-Time Retinal Imaging with a Parallel OCT Using a CMOS Smart Array Detector , 2007 .

[12]  R. Rosenfeld,et al.  Otitis media , 1994, The Lancet.

[13]  Zhongping Chen,et al.  Imaging the Human Tympanic Membrane Using Optical Coherence Tomography In Vivo , 2008, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[14]  John S. Oghalai,et al.  Quantitative imaging of cochlear soft tissues in wild-type and hearing-impaired transgenic mice by spectral domain optical coherence tomography , 2011, Optics express.

[15]  B. Wong,et al.  In Vivo Optical Coherence Tomography of the Human Larynx: Normative and Benign Pathology in 82 Patients , 2005, The Laryngoscope.

[16]  J G Fujimoto,et al.  High-resolution imaging of the middle ear with optical coherence tomography: a feasibility study. , 2001, Archives of otolaryngology--head & neck surgery.

[17]  I. Brook,et al.  Otitis media. , 2012, Future microbiology.

[18]  Hannover,et al.  Erste Anwendungen der optischen Kohärenztomographie (OCT) in der Mittelohrchirurgie , 2002 .

[19]  Joseph A Izatt,et al.  High-speed complex conjugate resolved retinal spectral domain optical coherence tomography using sinusoidal phase modulation. , 2007, Optics letters.

[20]  D. Lim,et al.  Structure and function of the tympanic membrane: a review. , 1995, Acta oto-rhino-laryngologica Belgica.

[21]  N. Cho,et al.  Development of SD-OCT for Imaging the in vivo Human Tympanic Membrane , 2011 .

[22]  S. Nittrouer,et al.  The role of early language experience in the development of speech perception and phonological processing abilities: evidence from 5-year-olds with histories of otitis media with effusion and low socioeconomic status. , 2005, Journal of communication disorders.

[23]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[24]  Eva Lankenau,et al.  Optical coherence tomography as an orientation guide in cochlear implant surgery? , 2007, Acta oto-laryngologica.

[25]  Cac T. Nguyen,et al.  Noninvasive in vivo optical detection of biofilm in the human middle ear , 2012, Proceedings of the National Academy of Sciences.

[26]  S. Dommerich,et al.  Temporal bone investigations on landmarks for conventional or endosteal insertion of cochlear electrodes , 2007, Acta oto-laryngologica.

[27]  R. Rosenfeld,et al.  Otitis media and speech and language: a meta-analysis of prospective studies. , 2004, Pediatrics.

[28]  T Lenarz,et al.  [Application of Optical Coherence Tomography (OCT) in middle ear surgery]. , 2002, Laryngo- rhino- otologie.

[29]  Steven L. Jacques,et al.  Low coherence interferometry of the cochlear partition , 2006, Hearing Research.

[30]  B. Wong,et al.  Optical coherence tomography of the rat cochlea. , 2000 .

[31]  Stephen A. Boppart,et al.  Non-invasive optical interferometry for the assessment of biofilm growth in the middle ear , 2010, Biomedical optics express.