Prospective randomized double-blind pilot study of site-specific consensus atlas implementation for rectal cancer target volume delineation in the cooperative group setting.

PURPOSE Variations in target volume delineation represent a significant hurdle in clinical trials involving conformal radiotherapy. We sought to determine the effect of a consensus guideline-based visual atlas on contouring the target volumes. METHODS AND MATERIALS A representative case was contoured (Scan 1) by 14 physician observers and a reference expert with and without target volume delineation instructions derived from a proposed rectal cancer clinical trial involving conformal radiotherapy. The gross tumor volume (GTV), and two clinical target volumes (CTVA, including the internal iliac, presacral, and perirectal nodes, and CTVB, which included the external iliac nodes) were contoured. The observers were randomly assigned to receipt (Group A) or nonreceipt (Group B) of a consensus guideline and atlas for anorectal cancers and then instructed to recontour the same case/images (Scan 2). Observer variation was analyzed volumetrically using the conformation number (CN, where CN = 1 equals total agreement). RESULTS Of 14 evaluable contour sets (1 expert and 7 Group A and 6 Group B observers), greater agreement was found for the GTV (mean CN, 0.75) than for the CTVs (mean CN, 0.46-0.65). Atlas exposure for Group A led to significantly increased interobserver agreement for CTVA (mean initial CN, 0.68, after atlas use, 0.76; p = .03) and increased agreement with the expert reference (initial mean CN, 0.58; after atlas use, 0.69; p = .02). For the GTV and CTVB, neither the interobserver nor the expert agreement was altered after atlas exposure. CONCLUSION Consensus guideline atlas implementation resulted in a detectable difference in interobserver agreement and a greater approximation of expert volumes for the CTVA but not for the GTV or CTVB in the specified case. Visual atlas inclusion should be considered as a feature in future clinical trials incorporating conformal RT.

[1]  W. Small,et al.  Consensus guidelines for delineation of clinical target volume for intensity-modulated pelvic radiotherapy in postoperative treatment of endometrial and cervical cancer. , 2008, International journal of radiation oncology, biology, physics.

[2]  C. Ménard,et al.  RTOG GU Radiation oncology specialists reach consensus on pelvic lymph node volumes for high-risk prostate cancer. , 2009, International journal of radiation oncology, biology, physics.

[3]  R. Cowan,et al.  Assessing the effect of a contouring protocol on postprostatectomy radiotherapy clinical target volumes and interphysician variation. , 2009, International journal of radiation oncology, biology, physics.

[4]  J. Dimopoulos,et al.  Inter- and intraobserver variation in HR-CTV contouring: intercomparison of transverse and paratransverse image orientation in 3D-MRI assisted cervix cancer brachytherapy. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  N G Burnet,et al.  A novel algorithm for the morphometric assessment of radiotherapy treatment planning volumes. , 2010, The British journal of radiology.

[6]  Jake Van Dyk,et al.  Improving the consistency in cervical esophageal target volume definition by special training. , 2002, International journal of radiation oncology, biology, physics.

[7]  Harold O. Wyckoff,et al.  International Commission ON Radiation Units and Measurements (ICRU). , 1974, The American journal of roentgenology, radium therapy, and nuclear medicine.

[8]  Neil G Burnet,et al.  Quantitative assessment of inter-clinician variability of target volume delineation for medulloblastoma: quality assurance for the SIOP PNET 4 trial protocol. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  A. Nichol,et al.  Consistency in seroma contouring for partial breast radiotherapy: impact of guidelines. , 2006, International journal of radiation oncology, biology, physics.

[10]  Suresh Senan,et al.  Use of CD-ROM-based tool for analyzing contouring variations in involved-field radiotherapy for Stage III NSCLC. , 2005, International journal of radiation oncology, biology, physics.

[11]  Karin Haustermans,et al.  Definition and delineation of the clinical target volume for rectal cancer. , 2006, International journal of radiation oncology, biology, physics.

[12]  J P Logue,et al.  Clinical variability of target volume description in conformal radiotherapy planning. , 1998, International journal of radiation oncology, biology, physics.

[13]  M van Herk,et al.  Definition of the prostate in CT and MRI: a multi-observer study. , 1999, International journal of radiation oncology, biology, physics.

[14]  C. Njeh,et al.  Tumor delineation: The weakest link in the search for accuracy in radiotherapy , 2008, Journal of medical physics.

[15]  Edgar Erdfelder,et al.  G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences , 2007, Behavior research methods.

[16]  Giovanna Rizzo,et al.  Target delineation in post-operative radiotherapy of brain gliomas: interobserver variability and impact of image registration of MR(pre-operative) images on treatment planning CT scans. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  Jeremy L Millar,et al.  Post-prostatectomy radiation therapy: consensus guidelines of the Australian and New Zealand Radiation Oncology Genito-Urinary Group. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[18]  Michael Bremer,et al.  The delineation of target volumes for radiotherapy of lung cancer patients. , 2009, Radiotherapy and Oncology.

[19]  M van Herk,et al.  The potential impact of CT-MRI matching on tumor volume delineation in advanced head and neck cancer. , 1997, International journal of radiation oncology, biology, physics.

[20]  Marco Brambilla,et al.  FDG-PET/CT imaging for staging and target volume delineation in preoperative conformal radiotherapy of rectal cancer. , 2008, International journal of radiation oncology, biology, physics.

[21]  Georges Noël,et al.  Conformity index: a review. , 2006, International journal of radiation oncology, biology, physics.

[22]  Michel Bolla,et al.  Guidelines for target volume definition in post-operative radiotherapy for prostate cancer, on behalf of the EORTC Radiation Oncology Group. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[23]  Franca Foppiano,et al.  The impact of contouring uncertainty on rectal 3D dose-volume data: results of a dummy run in a multicenter trial (AIROPROS01-02). , 2003, International journal of radiation oncology, biology, physics.

[24]  M. Moerland,et al.  A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: application to the prostate. , 1997, International journal of radiation oncology, biology, physics.

[25]  C. Hess,et al.  The Impact of Gross Tumor Volume (GTV) and Clinical Target Volume (CTV) Definition on the Total Accuracy in Radiotherapy , 2003, Strahlentherapie und Onkologie.

[26]  S Senan,et al.  Evaluation of a target contouring protocol for 3D conformal radiotherapy in non-small cell lung cancer. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[27]  K. Ang,et al.  CT-based delineation of lymph node levels and related CTVs in the node-negative neck: DAHANCA, EORTC, GORTEC, NCIC,RTOG consensus guidelines. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[28]  Marcel van Herk,et al.  Observer variation in target volume delineation of lung cancer related to radiation oncologist-computer interaction: a 'Big Brother' evaluation. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[29]  Marcel van Herk,et al.  Reduction of observer variation using matched CT-PET for lung cancer delineation: a three-dimensional analysis. , 2006, International Journal of Radiation Oncology, Biology, Physics.

[30]  Issam El Naqa,et al.  Elective clinical target volumes for conformal therapy in anorectal cancer: a radiation therapy oncology group consensus panel contouring atlas. , 2009, International journal of radiation oncology, biology, physics.

[31]  Masahiko Oguchi,et al.  Dummy run for a phase II multi-institute trial of chemoradiotherapy for unresectable pancreatic cancer: inter-observer variance in contour delineation. , 2007, Anticancer research.

[32]  W. Woodward,et al.  Variability of target and normal structure delineation for breast cancer radiotherapy: an RTOG Multi-Institutional and Multiobserver Study. , 2007, International journal of radiation oncology, biology, physics.

[33]  Jean-François Valley,et al.  The Reasons for Discrepancies in Target Volume Delineation , 2006, Strahlentherapie und Onkologie.

[34]  M. V. van Herk,et al.  Quantification of local rectal wall displacements by virtual rectum unfolding. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[35]  Nancy Lee,et al.  Head-and-neck target delineation among radiation oncology residents after a teaching intervention: a prospective, blinded pilot study. , 2009, International journal of radiation oncology, biology, physics.

[36]  Karin Haustermans,et al.  IGRT in rectal cancer , 2008, Acta oncologica.

[37]  Christian Kirisits,et al.  Inter-observer comparison of target delineation for MRI-assisted cervical cancer brachytherapy: application of the GYN GEC-ESTRO recommendations. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[38]  Lei Dong,et al.  Reduce in variation and improve efficiency of target volume delineation by a computer-assisted system using a deformable image registration approach. , 2007, International journal of radiation oncology, biology, physics.

[39]  Cyrill Burger,et al.  Automated functional image-guided radiation treatment planning for rectal cancer. , 2005, International journal of radiation oncology, biology, physics.

[40]  J. Sonke,et al.  Target volume shape variation during hypo-fractionated preoperative irradiation of rectal cancer patients. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[41]  Guido Gerig,et al.  User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability , 2006, NeuroImage.

[42]  Maximilien Vermandel,et al.  Automatic segmentation of pelvic structures from magnetic resonance images for prostate cancer radiotherapy. , 2007, International journal of radiation oncology, biology, physics.

[43]  S. Davies,et al.  Big brother : Britain's web of surveillance and the new technological order , 1996 .