Evaluation of two prototype devices producing noninvasive, pulsatile, calibrated blood pressure measurement from a finger

We evaluated two prototype instruments that measure pulsatile blood pressure continuously and noninvasively and compared the mean arterial pressure obtained from these devices with that obtained mvasivcly m 17 male surgical patients. Each prototype consisted of an infrared photoplethysmograph mounted inside a finger cuff. The cuff was connected to a pressure control valve, which rapidly changed the cuff pressure so as to maintain a null pressure difference across the finger arterial wall. The resultant cuff pressure rapidly tracked the pulsatile intraarterial pressure. The prototypes reproduced absolute pressure, as well as pressure changes, accurately and linearly over a wide range of mean arterial pressures (from 2 to 164 mm Hg), with an average offset error of 0.8 mm Hg (SD ± 3.8; range, -4.6 to 7.9), a mean scatter error of 5.3 mm Hg (range, 3.6 to 8.6), a mean regression slope of 0.97 (range, 0.79 to 1.22) and a mean correlation coefficient of the regression of 0.96 (range, 0.89 to 0.98).Both prototypes worked satisfactorily on all 17 patients, but not all the time on all patients. In 7 patients, probable arterial spasm prevented measurement of finger blood pressure 12.1% of the time, or 5.4% of the time for all patients. Ninety-six percent of the lost samples occurred with prototype 2, suggesting an instrument-related cause, rather than one related to the principle itself.The prototypes were simple to use and were almost free from artifact. Continuous monitoring for up to 7 hours on a single finger caused no harm to the finger.

[1]  M. Ramsey Noninvasive automatic determination of mean arterial pressure , 2006, Medical and Biological Engineering and Computing.

[2]  London Sb,et al.  Comparison of indirect pressure measurements (Korotkoff) with simultaneous direct brachial artery pressure distal to the cuff. , 1967 .

[3]  E. Dodd,et al.  Statistical Methods—Applied to Experiments in Agriculture and Biology , 1939 .

[4]  D. W. Hill The direct and indirect measurement of blood pressure , 1970, Medical and biological engineering.

[5]  H. W. Shirer,et al.  Blood pressure measuring methods. , 1962, IRE transactions on bio-medical electronics.

[6]  S B London,et al.  Comparison of indirect pressure measurements (Korotkoff) with simultaneous direct brachial artery pressure distal to the cuff. , 1967, Advances in internal medicine.

[7]  F. B. Allen,et al.  Can we trust the direct radial artery pressure immediately following cardiopulmonary bypass , 1982 .

[8]  J. Bruner,et al.  Comparison of direct and indirect methods of measuring arterial blood pressure, part III. , 1981, Medical instrumentation.

[9]  A. Treloar,et al.  Circulation A Journal of the American-Heart Association Comparison of Indirect and Direct Methods of Measuring Arterial Blood Pressure , 2005 .

[10]  Bruner Jm,et al.  Comparison of direct and indirect methods of measuring arterial blood pressure, part III. , 1981 .

[11]  T Togawa,et al.  Indirect measurement of instantaneous arterial blood pressure in the rat. , 1979, The American journal of physiology.

[12]  I. Dimich,et al.  Evaluating indirect blood pressure measurement techniques: a comparison of three systems in infants and children. , 1978, Pediatrics.

[13]  Tatsuo Togawa,et al.  Indirect Measurement of Instantaneous Arterial Blood Pressure in the Human Finger by the Vascular Unloading Technique , 1980, IEEE Transactions on Biomedical Engineering.

[14]  J. Bruner,et al.  Comparison of direct and indirect measuring arterial blood pressure. , 1981, Medical instrumentation.

[15]  T. Togawa,et al.  Noninvasive automatic monitoring of instantaneous arterial blood pressure using the vascular unloading technique , 1983, Medical and Biological Engineering and Computing.

[16]  A K Ream,et al.  Indirect measurement of mean blood pressure in the anesthetized patient. , 1979, Anesthesiology.