Endoscopic removal of an incidentally discovered intrauterine contraceptive device eroding into the rectum

Intrauterine contraceptive device (IUCD) is a common birth control method. It is safe but can be associated with serious complications including migration into the peritoneal cavity and penetration into other intra-abdominal and pelvic viscera; most commonly the rectosigmoid colon. Different retrieval methods including endoscopy, laparoscopy or open abdominal surgery have been described. We report the case of 38-year-old woman who became pregnant shortly after insertion of the IUCD 6 years prior to presentation. She delivered vaginally and ‘expulsion’ of the device was assumed. Some 4 years later, she had another IUCD inserted and remained asymptomatic till she recently presented with iron-deficiency anaemia. As part of the investigation, diagnostic colonoscopy was performed. Surprisingly, the old IUCD was found penetrating into the midrectum. Uneventful endoscopic removal was performed and she remained well at 3-month follow-up. Migrating IUCD remains asymptomatic and may be discovered accidentally during routine investigation for some other symptoms.

[1]  A. Burgos García,et al.  Colorectal penetration by two intrauterine devices. , 2019, Revista espanola de enfermedades digestivas : organo oficial de la Sociedad Espanola de Patologia Digestiva.

[2]  F. Ji,et al.  Sigmoid colon translocation of an intrauterine device misdiagnosed as a colonic polyp , 2018, Medicine.

[3]  I. Korbi,et al.  Pelvic abscess complicating sigmoid colon perforation by migrating intrauterine device: A case report and review of the literature , 2017, International journal of surgery case reports.

[4]  S. D. de Montbrun,et al.  An unconventional therapeutic approach to a migratory IUD causing perforation of the rectum , 2016, Journal of surgical case reports.

[5]  S. Yilmaz,et al.  Sigmoid Colon Migration of an Intrauterine Device , 2014, Case reports in obstetrics and gynecology.

[6]  Amila Weerasekera,et al.  Sigmoid colocolic fistula caused by intrauterine device migration: a case report , 2014, Journal of Medical Case Reports.

[7]  M. Ingec,et al.  Minimally invasive approach to cases of lost intra-uterine device: a 7-year experience. , 2011, European journal of obstetrics, gynecology, and reproductive biology.

[8]  J. Kaufman,et al.  Laparoscopic Retrieval of Intrauterine Device Perforating the Sigmoid Colon , 2010, JSLS : Journal of the Society of Laparoendoscopic Surgeons.

[9]  A. Meshikhes,et al.  Laparoscopic removal of a migrated intrauterine contraceptive device , 2010, Journal of obstetrics and gynaecology : the journal of the Institute of Obstetrics and Gynaecology.

[10]  M. Kanat-Pektas,et al.  Colon penetration by a copper intrauterine device: a case report with literature review , 2009, Archives of Gynecology and Obstetrics.

[11]  L. Sentilhes,et al.  Incidental finding of an intrauterine device in the sigmoid colon , 2008, The European journal of contraception & reproductive health care : the official journal of the European Society of Contraception.

[12]  M. A. Raja,et al.  Colonoscopic retrieval of a lost intrauterine contraceptive device: A case report and review of articles , 2005, The European journal of contraception & reproductive health care : the official journal of the European Society of Contraception.

[13]  A. García-Rodríguez,et al.  Intrauterine device removal from the sigmoid colon during a screening colonoscopy , 2015, Endoscopy.

[14]  R. Gill,et al.  Laparoscopic removal of an intra-abdominal intrauterine device: case and systematic review. , 2012, Contraception.