Performance of Model-based Predictive Control of the Ventilation Rate with Axial Fans

A new algorithm for ventilation rate control in mechanically ventilated buildings was developed and evaluated on a laboratory test installation. It was demonstrated that the current problems with traditional control of axial fans, such as instability due to dynamic wind actions, could be overcome by using a model-based predictive control (MBPC) algorithm. In the laboratory test installation, the performance of the MBPC algorithm was compared to the performance of a traditional proportional, integral, derivative (PID) controller in an airflow range from 1000 to 5000 m3/h (20–100% of fan capacity) and in a normal pressure range from 0 to 60 Pa. The accuracy and the stability of the ventilation rate control and the energy consumption were studied for both control algorithms. It was concluded that the main advantage of a MBPC algorithm over a PID controller lies in its stability in a wider range of the ventilation rates and pressure differences due to an automatic adaptation of the control parameters. The PID algorithm with fixed settings did not generate a stable control of the ventilation rate when the target value deviated more than 500 m3/h (16% of centre capacity) from the ventilation rate that it was optimised for, whereas the MBPC controller remained stable throughout the complete working range of the fan.

[1]  J. M. Randall 19 – VENTILATION SYSTEM DESIGN , 1981 .

[2]  Yuanhui Zhang,et al.  An Evaluation of Heating and Ventilation Control Strategies for Livestock Buildings , 1995 .

[3]  J. Hartung,et al.  Concentrations and emissions of airborne dust in livestock buildings in Northern Europe , 1998 .

[4]  J. T. Stitt,et al.  Heat loss from animals and man: J. L. Monteith and L. E. Mount (Editors). Butterworth, London, 1974, 457 pp., £10.00 , 1976 .

[5]  Daniel Berckmans,et al.  Development of a computer-based hierarchical control system for livestock buildings , 1992 .

[6]  Daniel Berckmans,et al.  Sensor for Continuous Measurement of the Ventilation Rate in Livestock Buildings , 1991 .

[7]  P.W.G. Groot Koerkamp,et al.  The development of robust methods for measuring concentrations and emission rates of gaseous and particulate air pollutants in livestock buildings , 1998 .

[8]  Daniel Berckmans,et al.  Relationships between physical characteristics of the pig house, the engineering and control-systems of the environment, and production parameters of growing-pigs , 1985 .

[9]  Erik Vranken Analysis and optimisation of ventilation control in livestock buildings , 1999 .

[10]  Theo Demmers,et al.  SE—Structure and Environment: Validation of Ventilation Rate Measurement Methods and the Ammonia Emission from Naturally Ventilated Dairy and Beef Buildings in the United Kingdom , 2001 .

[11]  Daniel Berckmans,et al.  Development of new control techniques for the ventilation and heating of livestock buildings , 1986 .

[12]  C. R. Boon,et al.  Comparison of Predicted and Measured Air Flow Patterns in a Mechanically Ventilated Livestock Building without Animals , 1997 .

[13]  J. Hartung,et al.  Concentrations and emissions of ammonia in livestock buildings in Northern Europe , 1998 .

[14]  A. Heber,et al.  Air Patterns and Turbulence in an Experimental Livestock Building , 1996 .

[15]  Nick Sigrimis,et al.  FUZZY LOGIC CONTROLLER DESIGN FOR STAGED HEATING AND VENTILATING SYSTEMS , 2000 .

[16]  G. A. Carpenter 19 – VENTILATION OF BUILDINGS FOR INTENSIVELY HOUSED LIVESTOCK , 1974 .

[17]  A J Heber,et al.  Predicting variable-speed fan performance from motor and impeller characteristics. I. Using complete motor data. , 1995 .

[18]  Daniel Berckmans,et al.  Proportional-Integral-Plus (PIP) Control of Agricultural Buildings , 2000 .

[19]  Richard S Gates,et al.  Design of switching control systems for ventilated greenhouses , 1996 .

[20]  Yuanhui Zhang,et al.  Variable Ventilation Rate Control Below the Heat-deficit Temperature in Cold-climate Livestock Buildings , 1993 .

[21]  Daniel Berckmans,et al.  Efficiency of climate control equipment in pig houses , 1988 .

[22]  J. Hartung,et al.  A Survey of Ventilation Rates in Livestock Buildings in Northern Europe , 1998 .

[23]  T. Hinz,et al.  A comprehensive experimental study of aerial pollutants in and emissions from livestock buildings. Part 1 : Methods , 1998 .

[24]  Peter Young,et al.  Parameter estimation for continuous-time models - A survey , 1979, Autom..

[25]  V. R. Phillips,et al.  A review of methods for measuring emission rates of ammonia from livestock buildings and slurry or manure stores, Part 2 : monitoring flux rates, concentrations and airflow rates , 2000 .

[26]  Marko Bacic,et al.  Model predictive control , 2003 .

[27]  C. Boon The effect of departures from lower critical temperature on the group postural behaviour of pigs , 1981 .

[28]  Theo Demmers,et al.  Assessment of Techniques for Measuring the Ventilation Rate, using an Experimental Building Section , 2000 .