Integrated refractive index sensor using silicon slot waveguides.
暂无分享,去创建一个
Fang Liu | Kaiyu Cui | Xue Feng | Wei Zhang | Yidong Huang | K. Cui | Xue Feng | Wei Zhang | Yidong Huang | Ka Li | Fang Liu | Kathryn D. Li
[1] Rebecca J. Anthony,et al. High-efficiency silicon nanocrystal light-emitting devices. , 2011, Nano letters.
[2] M. Rajarajan,et al. Label-free slot-waveguide biosensor for the detection of DNA hybridization. , 2012, Applied optics.
[3] Chung-Yen Chao,et al. Design and optimization of microring resonators in biochemical sensing applications , 2006, Journal of Lightwave Technology.
[4] Qianfan Xu,et al. Guiding and confining light in void nanostructure. , 2004, Optics letters.
[5] Y S Shubin,et al. Fluorescence‐based array biosensors for detection of biohazards , 2004, Journal of applied microbiology.
[6] Katrin Schmitt,et al. Interferometric biosensor based on planar optical waveguide sensor chips for label-free detection of surface bound bioreactions. , 2007, Biosensors & bioelectronics.
[7] K. Cui,et al. Designing low transmission loss silicon slot waveguide at wavelength band of high material absorption , 2013 .
[8] Y. Vlasov,et al. Losses in single-mode silicon-on-insulator strip waveguides and bends. , 2004, Optics express.
[9] Amadeu Griol,et al. Label-free optical biosensing with slot-waveguides. , 2008, Optics letters.
[10] M. Green,et al. Efficient silicon light-emitting diodes , 2001, Nature.
[11] Yuze Sun,et al. Sensitive optical biosensors for unlabeled targets: a review. , 2008, Analytica chimica acta.
[12] Fang Liu,et al. Experimental demonstration of silicon slot waveguide with low transmission loss at 1064 nm , 2014 .
[13] Phillip H. Paul,et al. Fiber‐optic evanescent field absorption sensor , 1987 .
[14] B. Rahman,et al. Optimization of a horizontal slot waveguide biosensor to detect DNA hybridization. , 2015, Applied optics.
[15] Laura M. Lechuga,et al. Silicon Photonic Biosensors for Lab-on-a-Chip Applications , 2008 .
[16] E. Sani,et al. Spectral optical constants of ethanol and isopropanol from ultraviolet to far infrared , 2016 .
[17] T. Vo‐Dinh,et al. Biosensors and biochips: advances in biological and medical diagnostics , 2000, Fresenius' journal of analytical chemistry.
[18] B. Lamontagne,et al. A Silicon-on-Insulator Photonic Wire Based Evanescent Field Sensor , 2006, IEEE Photonics Technology Letters.
[19] Damià Barceló,et al. Biosensors as useful tools for environmental analysis and monitoring , 2006, Analytical and bioanalytical chemistry.
[20] L. Lechuga,et al. An integrated optical interferometric nanodevice based on silicon technology for biosensor applications , 2003 .
[21] B. D. Gupta,et al. Fiber-optic evanescent field absorption sensor: A theoretical evaluation , 1994 .
[22] I. Malitson. Interspecimen Comparison of the Refractive Index of Fused Silica , 1965 .
[23] K. Svoboda,et al. Biological applications of optical forces. , 1994, Annual review of biophysics and biomolecular structure.
[24] Lauro T. Kubota,et al. Review of the use of biosensors as analytical tools in the food and drink industries , 2002 .
[25] M. Green,et al. Optical properties of intrinsic silicon at 300 K , 1995 .
[26] Carlos Angulo Barrios,et al. Optical Slot-Waveguide Based Biochemical Sensors , 2009, Sensors.
[27] R Baets,et al. Glucose sensing by waveguide-based absorption spectroscopy on a silicon chip. , 2014, Biomedical optics express.