Tension Sensing for a Linear Actuated Catheter Robot

Cardiac ablation therapy is an effective minimally invasive treatment of cardiac arrhythmias. The procedure is delicate and complex in nature requiring particular sections of the heart to be ablated. When operated by an experienced electrophysiologist, the procedure normally takes 2 to 3 hours. It is often conducted under fluoroscopic X-ray guidance and longer procedure times can increase the radiation burden of both the operator and patient. Earlier, we had proposed a robot-assisted tendon-guided catheter that can be navigated using radiation-free MRI imaging. In this paper, we propose a tension-feedback mechanism that provides vital control over its guiding tendons. We describe how it can be achieved using tension sensing and demonstrate using experiments and finite element simulations that feedback based on accurate tension sensing is plausible.

[1]  Robert D. Howe,et al.  An active motion compensation instrument for beating heart mitral valve surgery , 2007, 2007 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[2]  Kaspar Althoefer,et al.  3-DOF MR-Compatible Multi-Segment Cardiac Catheter Steering Mechanism , 2022 .

[3]  Kaspar Althoefer,et al.  Control a contact sensing finger for surface haptic exploration , 2014, 2014 IEEE International Conference on Robotics and Automation (ICRA).

[4]  J. Dai,et al.  An indentation depth—force sensing wheeled probe for abnormality identification during minimally invasive surgery , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  Rajnikant V. Patel,et al.  A pseudo-rigid-body 3R model for a steerable ablation catheter , 2013, 2013 IEEE International Conference on Robotics and Automation.

[6]  Shouvik Haldar,et al.  Comparison of Robotic and Manual Persistent AF Ablation Using Catheter Contact Force Sensing: An International Multicenter Registry Study , 2014, Pacing and clinical electrophysiology : PACE.

[7]  I. Tunay Position control of catheters using magnetic fields , 2004, Proceedings of the IEEE International Conference on Mechatronics, 2004. ICM '04..

[8]  Kaspar Althoefer,et al.  An optical curvature sensor for flexible manipulators , 2013, 2013 IEEE International Conference on Robotics and Automation.

[9]  Guanrong Chen,et al.  Fuzzy PID control of a flexible-joint robot arm with uncertainties from time-varying loads , 1997, IEEE Trans. Control. Syst. Technol..

[10]  P. Dasgupta,et al.  Air-cushion force sensitive probe for soft tissue investigation during minimally invasive surgery , 2009, 2008 IEEE Sensors.

[11]  Kaspar Althoefer,et al.  Rolling mechanical imaging: A novel approach for soft tissue modelling and identification during minimally invasive surgery , 2008, 2008 IEEE International Conference on Robotics and Automation.

[12]  Kaspar Althoefer,et al.  Finger contact sensing and the application in dexterous hand manipulation , 2015, Autonomous Robots.

[13]  Kaspar Althoefer,et al.  Three-Degree-of-Freedom MR-Compatible Multisegment Cardiac Catheter Steering Mechanism , 2016, IEEE Transactions on Biomedical Engineering.

[14]  Kaspar Althoefer,et al.  MRI-Compatible Intensity-Modulated Force Sensor for Cardiac Catheterization Procedures , 2011, IEEE Transactions on Biomedical Engineering.

[15]  Shuxiang Guo,et al.  A novel master-slave robotic catheter system for Vascular Interventional Surgery , 2013, 2013 IEEE International Conference on Mechatronics and Automation.

[16]  Andrea Natale,et al.  Atrial fibrillation in 2012: Advances in catheter-ablation treatment of AF , 2013, Nature Reviews Cardiology.

[17]  YingLiang Ma,et al.  Surface flattening of the human left atrium and proof-of-concept clinical applications☆ , 2014, Comput. Medical Imaging Graph..

[18]  Daniel Rueckert,et al.  Left atrium pulmonary veins: segmentation and quantification for planning atrial fibrillation ablation , 2009, Medical Imaging.

[19]  Xiang Gao,et al.  Design study of an adaptive Fuzzy-PD controller for pneumatic servo system , 2005 .

[20]  Kaspar Althoefer,et al.  Miniaturized force-indentation depth sensor for tissue abnormality identification during laparoscopic surgery , 2010, 2010 IEEE International Conference on Robotics and Automation.

[21]  Robert D. Howe,et al.  Position Control of Motion Compensation Cardiac Catheters , 2011, IEEE Transactions on Robotics.

[22]  Eugenio Picano,et al.  Cancer and non-cancer brain and eye effects of chronic low-dose ionizing radiation exposure , 2012, BMC Cancer.

[23]  Kaspar Althoefer,et al.  A three-axial body force sensor for flexible manipulators , 2014, 2014 IEEE International Conference on Robotics and Automation (ICRA).