Influence of plasticizer on the selectivity of nitrate-sensitive CHEMFETs

By chemical modification of an ion-sensitive field-effect transistor, a sensor (CHEMFET) has been developed whose sensitivity for nitrate has been tested. A plasticized poly(vinyl chloride) (PVC) membrane, which contains lipophilic tetra-n-octyl-ammonium ions, is responsible for the nitrate sensitivity of the device. This membrane has been attached physically on top of a pH-buffered hydrogel, which itself has been attached covalently to the gate oxide of the field-effect transistor. The influence of the plasticizer in the PVC membrane on the selectivity pattern of the CHEMFET for the detection of nitrate has been investigated.

[1]  D. Reinhoudt,et al.  The transduction of host‐guest interactions into electronic signals by molecular systems , 1990 .

[2]  M. Rothmaier,et al.  Chloride-selective electrodes based on mercury organic compounds as neutral carriers , 1993 .

[3]  H. J. James,et al.  Coated wire ion-selective electrodes. , 1971, Analytical chemistry.

[4]  R. Taft,et al.  Linear Solvation Energy Relationships. Standard Molar Gibbs Free Energies and Enthalpies of Transfer of Ions from Water into Nonaqueous Solvents , 1988 .

[5]  G. Hefter Fluoride solvation - the case of the missing ion , 1991 .

[6]  S. Hassan,et al.  A new liquid-membrane electrode for selective determination of perchlorate. , 1986, Talanta.

[7]  J. Janata,et al.  Ion-selective field effect transistors with heterogeneous membranes , 1979 .

[8]  W. E. Morf,et al.  Anion-selective liquid membrane electrodes based on lipophilic quaternary ammonium compounds , 1984 .

[9]  H. Ache Analytical chemistry in nuclear technology , 1992 .

[10]  Shaojun Dong,et al.  Chloride chemical sensor based on an organic conducting polypyrrole polymer , 1988 .

[11]  P. C. Meier,et al.  Review: ion-selective electrodes in clinical chemistry. , 1977, Medical progress through technology.

[12]  D. Reinhoudt,et al.  New membrane materials for potassium-selective ion-sensitive field-effect transistors , 1990 .

[13]  W. C. Purdy,et al.  Ion-selective electrode with fixed quaternary phosphonium ion-sensing species , 1992 .

[14]  Albert van den Berg,et al.  Modification of ISFESTs by covalent anchoring of poly(hydroxyethyl methacrylate) hydrogel. Introduction of a thermodynamically defined semiconductor-sensing membrane interface , 1990 .

[15]  Elo Harald Hansen,et al.  New nitrate ion-selective electrodes based on quaternary ammonium compounds in nonporous polymer membranes , 1976 .

[16]  G. Horvai,et al.  Amperometric measurements with ion-selective electrode membranes in a flow system , 1990 .

[17]  G. Werner,et al.  A nitrate-selective electrode based on bis(triphenylphosphine)iminium salts. , 1989, Talanta.

[18]  V. Markin,et al.  The standard gibbs energy of ion resolvation and non-linear dielectric effects , 1987 .

[19]  A. Hulanicki,et al.  The effect of the solvent in the nitrate-selective electrode , 1978 .

[20]  D. Reinhoudt,et al.  Chemically modified field-effect transistors; a sodium ion selective sensor based on calix[4]arene receptor molecules , 1991 .

[21]  A. Machado,et al.  Influence of the nature of the support on the temperature ehaviour of “all-solid-state” PVC membrane nitrate ISEs , 1990 .

[22]  D. Reinhoudt,et al.  Transduction of selective recognition of heavy metal ions by chemically modified field effect transistors (CHEMFETs) , 1992 .

[23]  K. Seiler,et al.  Reversible optical sensing membrane for the determination of chloride in serum , 1991 .

[24]  J. Ruzicka,et al.  Selectrode—the universal ion-selective electrode : Part VII. A valinomycin-based potassium electrode with nonporous polymer membrane and solid-state inner reference system , 1973 .

[25]  D. Reinhoudt,et al.  Membrane potentials of membranes with fixed ionic sites , 1990 .