Fiducial Optimization for Minimal Target Registration Error in Image-Guided Neurosurgery

This paper presents new methods for the optimal selection of anatomical landmarks and optimal placement of fiducial markers in image-guided neurosurgery. These methods allow the surgeon to optimally plan fiducial marker locations on routine diagnostic images before preoperative imaging and to intraoperatively select the set of fiducial markers and anatomical landmarks that minimize the expected target registration error (TRE). The optimization relies on a novel empirical simulation-based TRE estimation method built on actual fiducial localization error (FLE) data. Our methods take the guesswork out of the registration process and can reduce localization error without additional imaging and hardware. Our clinical experiments on five patients who underwent brain surgery with a navigation system show that optimizing one marker location and the anatomical landmarks configuration reduced the TRE. The average TRE values using the usual fiducials setup and using the suggested method were 4.7 mm and 3.2 mm, respectively. We observed a maximum improvement of 4 mm. Reducing the target registration error has the potential to support safer and more accurate minimally invasive neurosurgical procedures.

[1]  Hui Ding,et al.  The study of fiducial localization error of image in point-based registration , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[2]  Yan Yu,et al.  Optimal marker placement in photogrammetry patient positioning system. , 2003, Medical physics.

[3]  L. Joskowicz,et al.  Surface-based facial scan registration in neuronavigation procedures: a clinical study. , 2009, Journal of neurosurgery.

[4]  J. Michael Fitzpatrick,et al.  Fiducial registration error and target registration error are uncorrelated , 2009, Medical Imaging.

[5]  T. Peters Image-guidance for surgical procedures , 2006, Physics in medicine and biology.

[6]  J. Michael Fitzpatrick,et al.  Iterative solution for rigid-body point-based registration with anisotropic weighting , 2009, Medical Imaging.

[7]  Zhijian Song,et al.  Improving target registration accuracy in image‐guided neurosurgery by optimizing the distribution of fiducial points , 2009, The international journal of medical robotics + computer assisted surgery : MRCAS.

[8]  Purang Abolmaesumi,et al.  Distribution of Target Registration Error for Anisotropic and Inhomogeneous Fiducial Localization Error , 2009, IEEE Transactions on Medical Imaging.

[9]  G Baroni,et al.  Genetic evolutionary taboo search for optimal marker placement in infrared patient setup , 2007, Physics in medicine and biology.

[10]  Purang Abolmaesumi,et al.  Understanding the Effect of Bias in Fiducial Localization Error on Point-Based Rigid-Body Registration , 2010, IEEE Transactions on Medical Imaging.

[11]  L. Joskowicz,et al.  Target and Trajectory Clinical Application Accuracy in Neuronavigation , 2011, Neurosurgery.

[12]  K. Cleary,et al.  Image Guided Interventions. , 2020, Biomedizinische Technik. Biomedical engineering.

[13]  J. Michael Fitzpatrick,et al.  General Approach to First-Order Error Prediction in Rigid Point Registration , 2011, IEEE Transactions on Medical Imaging.

[14]  R. Maciunas,et al.  Computer-assisted neurosurgery. , 2005, Clinical neurosurgery.

[15]  Berthold K. P. Horn,et al.  Closed-form solution of absolute orientation using unit quaternions , 1987 .

[16]  Terry M. Peters,et al.  Real-Time Estimation of FLE Statistics for 3-D Tracking With Point-Based Registration , 2009, IEEE Transactions on Medical Imaging.

[17]  Terry M. Peters,et al.  A Statistical Model for Point-Based Target Registration Error With Anisotropic Fiducial Localizer Error , 2008, IEEE Transactions on Medical Imaging.

[18]  Nassir Navab,et al.  Online Estimation of the Target Registration Error for n -Ocular Optical Tracking Systems , 2007, MICCAI.

[19]  Jay B. West,et al.  The distribution of target registration error in rigid-body point-based registration , 2001, IEEE Transactions on Medical Imaging.

[20]  Jay B. West,et al.  Fiducial Point Placement and the Accuracy of Point-based, Rigid Body Registration , 2001, Neurosurgery.

[21]  Leo Joskowicz,et al.  Localization and registration accuracy in image guided neurosurgery: a clinical study , 2008, International Journal of Computer Assisted Radiology and Surgery.

[22]  Purang Abolmaesumi,et al.  On Fiducial Target Registration Error in the Presence of Anisotropic Noise , 2007, MICCAI.

[23]  Purang Abolmaesumi,et al.  A Theoretical Comparison of Different Target Registration Error Estimators , 2008, MICCAI.

[24]  K. Cleary,et al.  Image-guided interventions : technology and applications , 2008 .

[25]  Robert J. Maciunas,et al.  Registration of head volume images using implantable fiducial markers , 1997, IEEE Transactions on Medical Imaging.

[26]  Robert L. Galloway,et al.  Sensitivity analysis of fiducial placement on transorbital target registration error , 2008, International Journal of Computer Assisted Radiology and Surgery.

[27]  Purang Abolmaesumi,et al.  Estimation of Optimal Fiducial Target Registration Error in the Presence of Heteroscedastic Noise , 2010, IEEE Transactions on Medical Imaging.

[28]  Terry M. Peters,et al.  Improved Statistical TRE Model When Using a Reference Frame , 2007, MICCAI.

[29]  Leo Joskowicz,et al.  Worst-case analysis of target localization errors in fiducial-based rigid body registration , 2009, Medical Imaging.

[30]  Jay B. West,et al.  Predicting error in rigid-body point-based registration , 1998, IEEE Transactions on Medical Imaging.

[31]  Leo Joskowicz,et al.  Optimal landmarks selection and fiducial marker placement for minimal target registration error in image-guided neurosurgery , 2009, Medical Imaging.

[32]  R. Marmulla,et al.  Image-to-patient registration techniques in head surgery. , 2006, International journal of oral and maxillofacial surgery.

[33]  Benoit M. Dawant,et al.  Effect of MR Distortion on Targeting for Deep-Brain Stimulation , 2010, IEEE Transactions on Biomedical Engineering.

[34]  Purang Abolmaesumi,et al.  Point-Based Rigid-Body Registration Using an Unscented Kalman Filter , 2007, IEEE Transactions on Medical Imaging.

[35]  J M Fitzpatrick,et al.  The role of registration in accurate surgical guidance , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[36]  Leo Joskowicz,et al.  Geometrical analysis of registration errors in point-based rigid-body registration using invariants , 2011, Medical Image Anal..