New perspectives in ultrasensitive trace gas monitoring by cavity-enhanced laser absorption spectroscopy

Ultrasensitive optical spectroscopy technologies for environment monitoring, and in general, for gas analysis in the near Infrared are mainly based on the following spectroscopic methods: diode laser spectroscopy with multipass cells, with or without frequency modulation, photoacoustic spectroscopy, and since very recently, difference frequency spectroscopy with diode lasers. One of the most important issues of any monitoring technology, as important as the sensitivity, is its ability to provide absolute absorption coefficients without the need of complicated and cumbersome calibration procedures. Until now, two of the most sensitive optical spectroscopic technologies capable of providing this absolute information, Cavity Ringdown Spectroscopy and Intracavity Laser Absorption Spectroscopy have practically no use in this field. Due to recent advances, these two methods can now provide low-cost very compact field instruments working in the spectral range from 0.8 to 2.5 microns, with the smallest detectable absorption down to 10-10 (one over 10 billions) per one centimeter of the absorption path. This would result in the sub-ppb detection limit for moisture for example. Experimental results obtained with prototype field instruments developed by our group will be presented. Future perspectives will be discussed.

[1]  S. A. Kovalenko,et al.  Nonlinear dynamics of a multimode dye laser with an adjustable resonator dispersion and implications for the sensitivity of in-resonator laser spectroscopy , 1992 .

[2]  J. Maier,et al.  Cavity ringdown spectroscopy of molecular ions: A2Πu ← X2Σg+ (6−0) transition of N2+ , 1996 .

[3]  F. Stoeckel,et al.  Intracavity laser spectroscopy with vibronic solid-state lasers: II. Influence of the nonlinear mode coupling on the maximum sensitivity of a Ti:sapphire laser , 1995 .

[4]  J. Drummond,et al.  Tunable diode laser absorption spectrometer for ground‐based measurements of formaldehyde , 1997 .

[5]  F. Stoeckel,et al.  Quantitative measurements of very weak H2O absorption lines by time resolved intracavity laser spectroscopy , 1982 .

[6]  Arnaud Garnache,et al.  High sensitivity intra-cavity laser absorption spectroscopy with vertical external cavity surface emitting semiconductor lasers , 1999 .

[7]  F. Stoeckel,et al.  Intracavity absorption line shapes and quantitative measurements on O2 , 1983 .

[8]  D. Romanini,et al.  CW cavity ring down spectroscopy , 1997 .

[9]  J. J. Scherer,et al.  Infrared cavity ringdown laser absorption spectroscopy (IR-CRLAS) in low pressure flames , 1997 .

[10]  Frank K. Tittel,et al.  Real-time measurements of trace gases using a compact difference-frequency-based sensor operating at 3.5 μm , 1998 .

[11]  Richard N. Zare,et al.  Methyl radical measurement by cavity ring-down spectroscopy , 1995 .

[12]  Ted D. Lowes,et al.  Uniform threshold current, continuous-wave, singlemode 1300 nm vertical cavity lasers from 0 to 70°C , 1998 .

[13]  J. J. Scherer,et al.  Cavity ring down dye laser spectroscopy of jet-cooled metal clusters : Cu 2 and Cu 3 , 2000 .

[14]  A. O’Keefe,et al.  Cavity ring‐down optical spectrometer for absorption measurements using pulsed laser sources , 1988 .

[15]  P. Toschek,et al.  External photoacoustic detection of a trace vapor inside a multimode laser. , 1999, Applied optics.

[16]  V. Baev,et al.  Laser intracavity absorption spectroscopy , 1999 .

[17]  M. Kondow,et al.  Photopumped lasing at 1.25 μm of GaInNAs-GaAs multiple-quantum-well vertical-cavity surface-emitting lasers , 1997, IEEE Photonics Technology Letters.

[18]  D M Sonnenfroh,et al.  Absorption measurements of the second overtone band of NO in ambient and combustion gases with a 1.8-mum room-temperature diode laser. , 1997, Applied optics.

[19]  O'brien,et al.  Quantitative Intracavity Laser Spectroscopy Measurements with a Ti:sapphire Laser: Absorption Intensities for Water Vapor Lines in the 790-800 nm Region. , 1998, Journal of molecular spectroscopy.

[20]  David H. Parker,et al.  Coherent cavity ring down spectroscopy , 1994 .

[21]  Isabelle Sagnes,et al.  Room-temperature continuous-wave operation VCSEL at 1.48 /spl mu/m with Sb-based Bragg reflector , 1998 .

[22]  Daniele Romanini,et al.  Diode laser cavity ring down spectroscopy , 1997 .

[23]  Michael N. R. Ashfold,et al.  J-dependent linewidths for the (110)-(000) band of the Ã1A" - X1A' transition of HNO studied by cavity ring-down spectroscopy , 1996 .