Optimal time-window duration for computing time/frequency representations of normal phonocardiograms in dogs

The optimal duration of the time-window used to compute the time-frequency representation (spectrogram) of the phonocardiogram was studied in four dogs by using intracardiac and thoracic measurements of the PCG. The power and cross-spectrograms of the intracardiac and thoracic PCGs were computed using a fast Fourier transform algorithm and a sine-cosine window with 10 per cent decaying functions. A coherence spectrogram was also computed for each dog to study the linear relationship between the two signals and determine the optimal time-window duration. Results show that the optimal range of the time-window duration is between 16 and 32 ms. A time-window shorter than 16ms spreads out low-frequency components into the higher frequencies and generates a spectrographic representation with poor frequency resolution (≥62·5 Hz). A window larger than 32 ms increases the frequency resolution but smears the spectrographic representation of the signal in the time domain and thus cannot correctly reflect the time-varying properties of the signal. In both cases, the amplitude of the coherence function computed between the left ventricular and the thoracic phonocardiograms is overestimated.

[1]  T. Lanthier,et al.  Spectral analysis and acoustic transmission of mitral and aortic valve closure sounds in dogs , 1990, Medical and Biological Engineering and Computing.

[2]  Robert Guardo,et al.  Modeling of the Transfer Function of the Heart-Thorax Acoustic System in Dogs , 1985, IEEE Transactions on Biomedical Engineering.

[3]  T. Lanthier,et al.  Spectral analysis and acoustic transmission of mitral and aortic valve closure sounds in dogs , 2006, Medical and Biological Engineering and Computing.

[4]  R. Guardo,et al.  Comparison of air and contact microphones for estimating the acoustic transmission of heart sounds in dogs , 1986 .

[5]  Akira Iwata,et al.  Pattern classification of the phonocardiogram using linear prediction analysis , 2006, Medical and Biological Engineering and Computing.

[6]  C A Caceres,et al.  Heart sound analysis: a three dimensional approach. Contour plotting of sound for study of cardiovascular acoustics. , 1965, The American journal of cardiology.

[7]  T. Lanthier,et al.  Spectral analysis and acoustic transmission of mitral and aortic valve closure sounds in dogs. Part 1 Modelling the heart/thorax acoustic system , 1990, Medical and Biological Engineering and Computing.

[8]  T. Lanthier,et al.  Spectral analysis and acoustic transmission of mitral and aortic valve closure sounds in dogs , 2006, Medical and Biological Engineering and Computing.

[9]  J. Tukey,et al.  An algorithm for the machine calculation of complex Fourier series , 1965 .

[10]  W LIKOFF,et al.  Cardiospectrograms; a preliminary report. , 1954, American heart journal.

[11]  H. Griswold,et al.  Sound Spectrographic Diagnosis of Aortic Ball Variance , 1969, Circulation.

[12]  M. Portnoff Time-frequency representation of digital signals and systems based on short-time Fourier analysis , 1980 .