Evaluation of scatter effects on image quality for breast tomosynthesis

Digital breast tomosynthesis uses a limited number of low-dose x-ray projections to produce a three-dimensional (3D) tomographic reconstruction of the breast. The purpose of this investigation was to characterize and evaluate the effect of scatter radiation on image quality for breast tomosynthesis. Generated by a Monte Carlo simulation method, scatter point spread functions (PSF) were convolved over the field of view (FOV) to estimate the distribution of scatter for each angle of tomosynthesis projection. The results demonstrated that in the absence of scatter reduction techniques, the scatter-to-primary ratio (SPR) levels for the average breast are quite high (~0.4 at the centre of mass), and increased with increased breast thickness and with larger FOV. Associated with such levels of x-ray scatter are cupping artifacts, as well as reduced accuracy in reconstruction values. The effect of x-ray scatter on the contrast, noise, and signal-difference-to-noise ratio (SDNR) in tomosynthesis reconstruction was measured as a function of tumour size. For example, the contrast in the reconstructed central slice of a tumour-like mass (14 mm in diameter) was degraded by 30% while the inaccuracy of the voxel value was 28%, and the reduction of SDNR was 60%. We have quantified the degree to which scatter degrades the image quality over a wide range of parameters, including x-ray beam energy, breast thickness, breast diameter, and breast composition. However, even without a scatter rejection device, the contrast and SDNR in the reconstructed tomosynthesis slice is higher than that of conventional mammographic projection images acquired with a grid at an equivalent total exposure.

[1]  Idris Elbakri,et al.  Effect of scatter and an antiscatter grid on the performance of a slot-scanning digital mammography system. , 2006, Medical physics.

[2]  J A Seibert,et al.  X-ray scatter removal by deconvolution. , 1988, Medical physics.

[3]  P. C. Johns,et al.  X-ray characterisation of normal and neoplastic breast tissues. , 1987, Physics in medicine and biology.

[4]  Stefan Fiedler,et al.  Influence of scatter reduction method and monochromatic beams on image quality and dose in mammography. , 2003, Medical physics.

[5]  S. Richard,et al.  A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT. , 2005, Medical physics.

[6]  W Huda,et al.  Scattered radiation in scanning slot mammography. , 1998, Medical physics.

[7]  Chris C Shaw,et al.  Dual-energy digital mammography for calcification imaging: scatter and nonuniformity corrections. , 2005, Medical physics.

[8]  D. Jaffray,et al.  Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter. , 2001, Medical physics.

[9]  J. Boone,et al.  Scatter/primary in mammography: comprehensive results. , 2000, Medical physics.

[10]  R Fahrig,et al.  Performance of glass fiber antiscatter devices at mammographic energies. , 1994, Medical physics.

[11]  U Neitzel,et al.  Grids or air gaps for scatter reduction in digital radiography: a model calculation. , 1992, Medical physics.

[12]  J. Barnes Characteristics and control of contrast in CT. , 1992, Radiographics : a review publication of the Radiological Society of North America, Inc.

[13]  J M Boone,et al.  Scatter/primary in mammography: Monte Carlo validation. , 2000, Medical physics.

[14]  J. Boone Normalized glandular dose (DgN) coefficients for arbitrary X-ray spectra in mammography: computer-fit values of Monte Carlo derived data. , 2002, Medical physics.

[15]  Martin J Yaffe,et al.  A slot-scanned photodiode-array/CCD hybrid detector for digital mammography. , 2002, Medical physics.

[16]  J A Seibert,et al.  An edge spread technique for measurement of the scatter-to-primary ratio in mammography. , 2000, Medical physics.

[17]  J. Boone,et al.  Evaluation of x-ray scatter properties in a dedicated cone-beam breast CT scanner. , 2005, Medical physics.

[18]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[19]  Sabee Molloi,et al.  Effect of area x-ray beam equalization on image quality and dose in digital mammography. , 2004, Physics in medicine and biology.

[20]  S. C. Prasad,et al.  Scatter reduction in mammography with air gap. , 1996, Medical physics.