Micro-Raman Spectroscopy and Univariate Analysis for Monitoring Disease Follow-Up

Micro-Raman spectroscopy is a very promising tool for medical applications, thanks to its sensitivity to subtle changes in the chemical and structural characteristics of biological specimens. To fully exploit these promises, building a method of data analysis properly suited for the case under study is crucial. Here, a linear or univariate approach using a R2 determination coefficient is proposed for discriminating Raman spectra even with small differences. The validity of the proposed approach has been tested using Raman spectra of high purity glucose solutions collected in the 600 to 1,600 cm−1 region and also from solutions with two known solutes at different concentrations. After this validation step, the proposed analysis has been applied to Raman spectra from oral human tissues affected by Pemphigus Vulgaris (PV), a rare life-threatening autoimmune disease, for monitoring disease follow-up. Raman spectra have been obtained in the wavenumber regions from 1,050 to 1,700 cm−1 and 2,700 to 3,200 cm−1 from tissues of patients at different stages of pathology (active PV, under therapy and PV in remission stage) as confirmed by histopathological and immunofluorescence analysis. Differences in the spectra depending on tissue illness stage have been detected at 1,150–1,250 cm−1 (amide III) and 1,420–1,450 cm−1 (CH3 deformation) regions and around 1,650 cm−1 (amide I) and 2,930 cm−1 (CH3 symmetric stretch). The analysis of tissue Raman spectra by the proposed univariate method has allowed us to effectively differentiate tissues at different stages of pathology.

[1]  C. Hadjur,et al.  In vivo chemical investigation of human skin using a confocal Raman fiber optic microprobe. , 2005, Journal of biomedical optics.

[2]  M. Feld,et al.  Multicomponent blood analysis by near-infrared Raman spectroscopy. , 1999, Applied optics.

[3]  N. Cirillo,et al.  How does acantholysis occur in pemphigus vulgaris: a critical review , 2006, Journal of cutaneous pathology.

[4]  M. Temperini,et al.  Investigations of different carbohydrate anomers in copper(II) complexes with D-glucose, D-fructose, and D-galactose by Raman and EPR spectroscopy. , 2005, Carbohydrate research.

[5]  J. Taylor An Introduction to Error Analysis , 1982 .

[6]  Deanna L. Thompson,et al.  The effect of cell fixation on the discrimination of normal and leukemia cells with laser tweezers Raman spectroscopy , 2009, Biopolymers.

[7]  C. Krishna,et al.  Optical pathology of oral tissue: A raman spectroscopy diagnostic method , 2001 .

[8]  Mark D. Semon,et al.  POSTUSE REVIEW: An Introduction to Error Analysis: The Study of Uncertainties in Physical Measurements , 1982 .

[9]  G. Loppnow,et al.  Raman spectroscopy as a discovery tool in carbohydrate chemistry. , 2000, Analytical chemistry.

[10]  H. Bruining,et al.  In vivo confocal Raman microspectroscopy of the skin: noninvasive determination of molecular concentration profiles. , 2001, The Journal of investigative dermatology.

[11]  K. Fountas,et al.  Determination of water concentration in brain tissue by Raman spectroscopy. , 2001, Analytical chemistry.

[12]  Vesa-Pekka Lehto,et al.  Quantitative analysis of amorphous content of lactose using CCD-Raman spectroscopy. , 2005, Journal of pharmaceutical and biomedical analysis.

[13]  T. B. Bakker Schut,et al.  Discriminating basal cell carcinoma from perilesional skin using high wave-number Raman spectroscopy. , 2007, Journal of biomedical optics.

[14]  I. Delfino,et al.  Visible micro-Raman spectroscopy for determining glucose content in beverage industry. , 2011, Food chemistry.

[15]  Yrjö H. Roos,et al.  Raman spectra of fructose and glucose in the amorphous and crystalline states , 1999 .

[16]  C. Camerlingo,et al.  Wavelet data analysis of micro-Raman spectra for follow-up monitoring in oral pathologies , 2008, SPIE BiOS.

[17]  Steven W Booth,et al.  Quantitative analysis of mannitol polymorphs. FT-Raman spectroscopy. , 2002, Journal of pharmaceutical and biomedical analysis.

[18]  H. Lui,et al.  Raman spectroscopy for optical diagnosis in normal and cancerous tissue of the nasopharynx—preliminary findings , 2003, Lasers in surgery and medicine.

[19]  Wolfgang Petrich,et al.  Quantitative analysis of serum and serum ultrafiltrate by means of Raman spectroscopy. , 2004, The Analyst.

[20]  G. Zografi,et al.  The Quantitative Analysis of Crystallinity Using FT-Raman Spectroscopy , 1998, Pharmaceutical Research.

[21]  Y. Shirakata,et al.  In vitro keratinocyte dissociation assay for evaluation of the pathogenicity of anti-desmoglein 3 IgG autoantibodies in pemphigus vulgaris. , 2005, The Journal of investigative dermatology.

[22]  G. Puppels,et al.  Towards oncological application of Raman spectroscopy , 2009, Journal of biophotonics.

[23]  E. R. Cohen An Introduction to Error Analysis: The Study of Uncertainties in Physical Measurements , 1998 .

[24]  James L Lambert,et al.  Glucose determination in human aqueous humor with Raman spectroscopy. , 2005, Journal of biomedical optics.

[25]  A. G. Asuero,et al.  The Correlation Coefficient: An Overview , 2006 .

[26]  Ramasamy Manoharan,et al.  Histochemical analysis of biological tissues using Raman spectroscopy , 1996 .

[27]  C. Kontoyannis,et al.  Use of Raman Spectroscopy for the Quantitative Analysis of Calcium Oxalate Hydrates: Application for the Analysis of Urinary Stones , 1997 .

[28]  S. Skoulika,et al.  FT-Raman spectroscopy - analytical tool for routine analysis of diazinon pesticide formulations. , 2000, Talanta.

[29]  Maria Lepore,et al.  Investigation on Clarified Fruit Juice Composition by Using Visible Light Micro-Raman Spectroscopy , 2007, Sensors.

[30]  Ulrich J. Griesser,et al.  Qualitative and quantitative study of polymorphic forms in drug formulations by near infrared FT-Raman spectroscopy , 2003 .

[31]  R. Dasari,et al.  Prospects for in vivo Raman spectroscopy , 2000 .

[32]  V. B. Kartha,et al.  Discrimination of normal, inflammatory, premalignant, and malignant oral tissue: A Raman spectroscopy study , 2006, Biopolymers.

[33]  Nicola Cirillo,et al.  An Investigation on Micro-Raman Spectra and Wavelet Data Analysis for Pemphigus Vulgaris Follow-up Monitoring , 2008, Sensors.

[34]  M. Blanco,et al.  Development of a univariate calibration model for pharmaceutical analysis based on NIR spectra , 2008, Analytical and bioanalytical chemistry.

[35]  T C Bakker Schut,et al.  Tissue characterization using high wave number Raman spectroscopy. , 2005, Journal of biomedical optics.

[36]  R. Alfano,et al.  Human breast tissues studied by IR Fourier-transform Raman spectroscopy , 1991 .