Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction.

PURPOSE The ionizing radiation imparted to patients during computed tomography exams is raising concerns. This paper studies the performance of a scheme called dose reduction using prior image constrained compressed sensing (DR-PICCS). The purpose of this study is to characterize the effects of a statistical model of x-ray detection in the DR-PICCS framework and its impact on spatial resolution. METHODS Both numerical simulations with known ground truth and in vivo animal dataset were used in this study. In numerical simulations, a phantom was simulated with Poisson noise and with varying levels of eccentricity. Both the conventional filtered backprojection (FBP) and the PICCS algorithms were used to reconstruct images. In PICCS reconstructions, the prior image was generated using two different denoising methods: a simple Gaussian blur and a more advanced diffusion filter. Due to the lack of shift-invariance in nonlinear image reconstruction such as the one studied in this paper, the concept of local spatial resolution was used to study the sharpness of a reconstructed image. Specifically, a directional metric of image sharpness, the so-called pseudopoint spread function (pseudo-PSF), was employed to investigate local spatial resolution. RESULTS In the numerical studies, the pseudo-PSF was reduced from twice the voxel width in the prior image down to less than 1.1 times the voxel width in DR-PICCS reconstructions when the statistical model was not included. At the same noise level, when statistical weighting was used, the pseudo-PSF width in DR-PICCS reconstructed images varied between 1.5 and 0.75 times the voxel width depending on the direction along which it was measured. However, this anisotropy was largely eliminated when the prior image was generated using diffusion filtering; the pseudo-PSF width was reduced to below one voxel width in that case. In the in vivo study, a fourfold improvement in CNR was achieved while qualitatively maintaining sharpness; images also had a qualitatively more uniform noise spatial distribution when including a statistical model. CONCLUSIONS DR-PICCS enables to reconstruct CT images with lower noise than FBP and the loss of spatial resolution can be mitigated to a large extent. The introduction of statistical modeling in DR-PICCS may improve some noise characteristics, but it also leads to anisotropic spatial resolution properties. A denoising method, such as the directional diffusion filtering, has been demonstrated to reduce anisotropy in spatial resolution effectively when it was combined with DR-PICCS with statistical modeling.

[1]  Emmanuel J. Candès,et al.  Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information , 2004, IEEE Transactions on Information Theory.

[2]  Jean-Baptiste Thibault,et al.  A three-dimensional statistical approach to improved image quality for multislice helical CT. , 2007, Medical physics.

[3]  Rangasami L. Kashyap,et al.  Picture Reconstruction from Projections , 1975, IEEE Transactions on Computers.

[4]  Stephen P. Boyd,et al.  Compressed sensing based cone-beam computed tomography reconstruction with a first-order method. , 2010, Medical physics.

[5]  Jitendra Malik,et al.  Scale-Space and Edge Detection Using Anisotropic Diffusion , 1990, IEEE Trans. Pattern Anal. Mach. Intell..

[6]  Guang-Hong Chen,et al.  Dual energy CT using slow kVp switching acquisition and prior image constrained compressed sensing , 2010, Physics in medicine and biology.

[7]  Jie Tang,et al.  Prior image constrained compressed sensing: implementation and performance evaluation. , 2011, Medical physics.

[8]  Hakan Erdogan,et al.  Ordered subsets algorithms for transmission tomography. , 1999, Physics in medicine and biology.

[9]  Freek J. Beekman,et al.  Accelerated iterative transmission CT reconstruction using an ordered subsets convex algorithm , 1998, IEEE Transactions on Medical Imaging.

[10]  Max A. Viergever,et al.  Efficient and reliable schemes for nonlinear diffusion filtering , 1998, IEEE Trans. Image Process..

[11]  Guang-Hong Chen,et al.  Temporal Resolution Improvement using PICCS , 2009 .

[12]  Jeffrey A. Fessler,et al.  Regularization for uniform spatial resolution properties in penalized-likelihood image reconstruction , 2000, IEEE Transactions on Medical Imaging.

[13]  Guang-Hong Chen,et al.  Dose reduction using prior image constrained compressed sensing (DR-PICCS) , 2011, Medical Imaging.

[14]  Guang-Hong Chen,et al.  Perfusion measurements by micro-CT using prior image constrained compressed sensing (PICCS): initial phantom results , 2010, Physics in medicine and biology.

[15]  Guang-Hong Chen,et al.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study. , 2011, Medical physics.

[16]  Joachim Weickert,et al.  Coherence-Enhancing Diffusion Filtering , 1999, International Journal of Computer Vision.

[17]  Xiaochuan Pan,et al.  Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms. , 2009, Medical physics.

[18]  Jie Tang,et al.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. , 2008, Medical physics.

[19]  Ken D. Sauer,et al.  A unified approach to statistical tomography using coordinate descent optimization , 1996, IEEE Trans. Image Process..

[20]  Lei Zhu,et al.  Compressed sensing based cone-beam computed tomography reconstruction with a first-order methoda). , 2010, Medical physics.

[21]  Armando Manduca,et al.  Non-convex prior image constrained compressed sensing (NC-PICCS) , 2010, Medical Imaging.

[22]  Jiayu Song,et al.  Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT. , 2007, Medical physics.

[23]  S. Leng,et al.  High temporal resolution and streak-free four-dimensional cone-beam computed tomography , 2008, Physics in medicine and biology.

[24]  S. Manglos,et al.  Transmission maximum-likelihood reconstruction with ordered subsets for cone beam CT. , 1995, Physics in medicine and biology.

[25]  Bruce R. Whiting,et al.  Signal statistics in x-ray computed tomography , 2002, SPIE Medical Imaging.

[26]  Jerry L. Prince,et al.  Penalized-likelihood reconstruction for sparse data acquisitions with unregistered prior images and compressed sensing penalties , 2011, Medical Imaging.

[27]  J. Fessler,et al.  Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographs , 1996, 5th IEEE EMBS International Summer School on Biomedical Imaging, 2002..

[28]  Albert Macovski,et al.  A Maximum Likelihood Approach to Transmission Image Reconstruction from Projections , 1977, IEEE Transactions on Nuclear Science.

[29]  Guang-Hong Chen,et al.  Performance studies of four-dimensional cone beam computed tomography , 2011, Physics in medicine and biology.

[30]  Guang-Hong Chen,et al.  Reduced image noise at low-dose multidetector CT of the abdomen with prior image constrained compressed sensing algorithm. , 2011, Radiology.

[31]  S. Frick,et al.  Compressed Sensing , 2014, Computer Vision, A Reference Guide.

[32]  Guang-Hong Chen,et al.  Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT. , 2012, Medical physics.

[33]  Xiaochuan Pan,et al.  Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT , 2010, Physics in medicine and biology.

[34]  Guang-Hong Chen,et al.  Temporal resolution improvement using PICCS in MDCT cardiac imaging. , 2009, Medical physics.

[35]  David L Donoho,et al.  Compressed sensing , 2006, IEEE Transactions on Information Theory.

[36]  L. Rudin,et al.  Nonlinear total variation based noise removal algorithms , 1992 .

[37]  Jie Tang,et al.  Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms , 2009, Physics in medicine and biology.

[38]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[39]  Ken D. Sauer,et al.  A local update strategy for iterative reconstruction from projections , 1993, IEEE Trans. Signal Process..

[40]  M. Kachelriess,et al.  Improved total variation-based CT image reconstruction applied to clinical data , 2011, Physics in medicine and biology.

[41]  J Trzasko,et al.  Nonconvex prior image constrained compressed sensing (NCPICCS): theory and simulations on perfusion CT. , 2011, Medical physics.

[42]  Hanno Scharr,et al.  A Scheme for Coherence-Enhancing Diffusion Filtering with Optimized Rotation Invariance , 2002, J. Vis. Commun. Image Represent..

[43]  E. Candès,et al.  Stable signal recovery from incomplete and inaccurate measurements , 2005, math/0503066.

[44]  Jie Tang,et al.  Temporal resolution improvement using PICCS in MDCT cardiac imaging. , 2009 .

[45]  K. Lange,et al.  EM reconstruction algorithms for emission and transmission tomography. , 1984, Journal of computer assisted tomography.

[46]  Guang-Hong Chen,et al.  Time-Resolved Interventional Cardiac C-arm Cone-Beam CT: An Application of the PICCS Algorithm , 2012, IEEE Transactions on Medical Imaging.