Workstation interface for ROC studies in digital mammography

The goal of this project was the development of a workstation-user interface for evaluating computer assisted diagnosis (CAD) methods for digital mammography in receiver operating characteristic (ROC) experiments. Digital mammography poses significant and unique difficulties in the design and implementation of such an interface because multiple, large size images need to be handled at high- speeds. Furthermore, controls such as contrast, pan and zoom, and tools such as reporting forms, case information, and analysis of results need to be included. The software and hardware used to develop such a workstation and interface were based on Sun platforms and the Unix operating system. The software was evaluated by radiologists, and found to be user friendly, and comparable to standard mammography film reading in terms of display layout and speed. The software, as designed, will work on entry level workstations as well as high-end workstations with specialized hardware, thus being usable in either an educational, training, or clinical environment for annotation purposes using CAD techniques as well as primary diagnosis.

[1]  John B. Shoven,et al.  I , Edinburgh Medical and Surgical Journal.

[2]  Maryellen L. Giger Computer-aided diagnosis in digital mammography , 1993, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ.

[3]  G G Cox,et al.  Digital image management: networking, display, and archiving. , 1986, Radiologic clinics of North America.

[4]  Baoyu Zheng,et al.  Computer assisted diagnosis for digital mammography , 1995 .

[5]  C E Metz,et al.  Some practical issues of experimental design and data analysis in radiological ROC studies. , 1989, Investigative radiology.

[6]  C E Metz,et al.  Quantification of failure to demonstrate statistical significance. The usefulness of confidence intervals. , 1993, Investigative radiology.

[7]  K S Berbaum,et al.  Degeneracy and discrete receiver operating characteristic rating data. , 1995, Academic radiology.

[8]  Michael Hsieh,et al.  Pixel processing in a memory controller , 1995, IEEE Computer Graphics and Applications.

[9]  C. M. Hill Computer-aided diagnosis. , 1992, Dental update.

[10]  K. Hopper,et al.  Stereotactic breast biopsy with a biopsy gun. , 1990, Radiology.

[11]  C. Metz ROC Methodology in Radiologic Imaging , 1986, Investigative radiology.

[12]  Anthony Giles,et al.  Clinical workstation for digital mammography , 1993, Electronic Imaging.

[13]  J E Gray,et al.  Evaluation of mammographic viewbox luminance, illuminance, and color. , 1993, Medical physics.