Measurement of the force required to move a neurosurgical probe through in vivo human brain tissue

The advent of high-precision magnetic and robotic computer-controlled neurosurgery systems makes it necessary to determine the range of forces that will be encountered by the probes of such devices as they are guided through the brain tissues to intraparenchymal targets. The authors have measured the penetration forces on 2.5-mm spheres and the drag forces on 3.0-mm ventricular shunt catheters advanced 2.0-3.5 cm deep into in vivo human brain tissues (in patients about to have those tissues resected during epilepsy surgery) at rates of /spl ap/0.33 mm s/sup -1/. Penetration forces of (8/spl plusmn/2) grams were found for the spherical probe once it passed 0.5 cm below the cortical surface, and frictional drags of (2.8/spl plusmn/0.3) grams cm/sup -1/ were exerted on the catheters. The variable nature of these forces is discussed and the results are compared with earlier studies on experimental animal tissues and brain phantom gelatins. The implications of these results for magnetic and robotic surgery systems are considered.

[1]  A K Ommaya,et al.  Mechanical properties of tissues of the nervous system. , 1968, Journal of biomechanics.

[2]  J. Melvin,et al.  Dynamic mechanical properties of human brain tissue. , 1969, Journal of biomechanics.

[3]  A K Ommaya,et al.  A comparison of the elasticity of live, dead, and fixed brain tissue. , 1970, Journal of biomechanics.

[4]  J. Mcelhaney,et al.  A viscoelastic study of scalp, brain, and dura. , 1970, Journal of biomechanics.

[5]  R. Young,et al.  Application of robotics to stereotactic neurosurgery. , 1987, Neurological research.

[6]  M A Howard,et al.  Magnetic movement of a brain thermoceptor. , 1989, Neurosurgery.

[7]  M A Howard,et al.  Preliminary experimental investigation of in vivo magnetic manipulation: results and potential application in hyperthermia. , 1989, Medical physics.

[8]  M A Howard,et al.  Magnetic stereotaxis: a technique to deliver stereotactic hyperthermia. , 1990, Neurosurgery.

[9]  M A Howard,et al.  Nonlinear magnetic stereotaxis: three-dimensional, in vivo remote magnetic manipulation of a small object in canine brain. , 1990, Medical physics.

[10]  P. W. Roberts,et al.  Surgical force detection probe , 1991 .

[11]  Ping Tcheng,et al.  Surgical Force-Measuring Probe , 1993 .

[12]  William C. Broaddus,et al.  MAGNETIC MANIPULATION INSTRUMENTATION FOR MEDICAL PHYSICS RESEARCH , 1994 .

[13]  George T. Gillies,et al.  Review of magnetic neorosurgery research , 1995 .

[14]  D Glauser,et al.  Neurosurgical robot Minerva: first results and current developments. , 1995, Journal of image guided surgery.

[15]  G T Gillies,et al.  Review of magnetic neurosurgery research. , 1995, Journal of image guided surgery.

[16]  E. G. Quate,et al.  Measurement of friction on straight catheters in in vitro brain and phantom material , 1998, IEEE Transactions on Biomedical Engineering.