Design concept and mathematical model of a bi-fluid photovoltaic/thermal (PV/T) solar collector

This paper presents an improved design of a photovoltaic/thermal (PV/T) solar collector integrating a PV panel with a serpentine-shaped copper tube as the water heating component and a single pass air channel as the air heating component. In addition to the electricity generated, this type of collector enables the production of both hot air and water, increasing the total efficiency per unit area compared to the conventional PV/T solar collector. The use of both fluids (bi-fluid) also creates a greater range of thermal applications and offers options in which hot and/or cold air and/or water can be utilized depending on the energy needs and applications. In this paper, the design concept of the bi-fluid PV/T solar collector is emphasized with 2D steady state energy balance equations for the bi-fluid configuration are developed, validated and used to predict the performance of the bi-fluid solar collector for a range of mass flow rates of air and water. The performance of the collector is then compared when the fluids are operated independently and simultaneously. The simulations indicate that when both fluids are operated independently the overall thermal and electrical performance of the solar collector is considered as satisfactory and when operated simultaneously the overall performance is higher. The bi-fluid PV/T solar collector discussed in this paper will add insights to the new knowledge of optimizing the utilization of solar energy by a PV/T solar collector and has potential applications in various fields.

[1]  Weeratunge Malalasekera,et al.  An introduction to computational fluid dynamics - the finite volume method , 2007 .

[2]  S. Kalogirou,et al.  Optimization of the photovoltaic thermal (PV/T) collector absorber , 2011 .

[3]  G. N. Tiwari,et al.  Advanced Renewable Energy Sources , 2011 .

[4]  Tao Liu,et al.  A parametric study on the thermal performance of cross-corrugated solar air collectors , 2006 .

[5]  Andrew A. O. Tay,et al.  Testing of two different types of photovoltaic–thermal (PVT) modules with heat flow pattern under tropical climatic conditions , 2013 .

[6]  L. W. Florschuetz On heat rejection from terrestrial solar cell arrays with sunlight concentration , 1975 .

[7]  Yiannis Tripanagnostopoulos,et al.  Aspects and improvements of hybrid photovoltaic/thermal solar energy systems , 2007 .

[8]  W. Beckman,et al.  Solar Engineering of Thermal Processes , 1985 .

[9]  Kamaruzzaman Sopian,et al.  Performance analysis of a double-pass photovoltaic/thermal (PV/T) solar collector with CPC and fins , 2005 .

[10]  J. Brau,et al.  Study of a new concept of photovoltaic-thermal hybrid collector , 2007 .

[11]  K. S. Ong Thermal performance of solar air heaters: Mathematical model and solution procedure , 1995 .

[12]  E. Sparrow,et al.  Internal-flow Nusselt numbers for the low-Reynolds-number end of the laminar-to-turbulent transition regime , 2011 .

[13]  Oscar Cabeza,et al.  Experimental and numerical investigation of a flat-plate solar collector , 2010 .

[14]  M. Wolf,et al.  Performance analyses of combined heating and photovoltaic power systems for residences , 1976 .

[15]  Lap Mou Tam,et al.  Transitional Heat Transfer in Plain Horizontal Tubes , 2006 .

[16]  Himanshu Dehra,et al.  A two dimensional thermal network model for a photovoltaic solar wall , 2009 .

[17]  I. Dincer,et al.  Performance evaluation of a hybrid photovoltaic thermal (PV/T) (glass-to-glass) system , 2009 .

[18]  Swapnil Dubey,et al.  Thermal modeling of a combined system of photovoltaic thermal (PV/T) solar water heater , 2008 .

[19]  Said Farahat,et al.  An improved thermal and electrical model for a solar photovoltaic thermal (PV/T) air collector , 2010 .

[20]  S. C. Kaushik,et al.  Performance evaluation of solar air heater for various artificial roughness geometries based on energy, effective and exergy efficiencies , 2009 .

[21]  Ha Herbert Zondag,et al.  The thermal and electrical yield of a PV-thermal collector , 2002 .

[22]  Christophe Menezo,et al.  Hybrid Solar: A Review on Photovoltaic and Thermal Power Integration , 2012 .

[23]  M. Taki Al-Kamil,et al.  Effect of thermal radiation inside solar air heaters , 1997 .

[24]  B. N. Prasad,et al.  Effect of artificial roughness on heat transfer and friction factor in a solar air heater , 1988 .

[25]  Kamaruzzaman Sopian,et al.  Performance analysis of photovoltaic thermal air heaters , 1996 .

[26]  M. Rosen,et al.  Performance evaluation of a double pass PV/T solar air heater with and without fins , 2011 .

[27]  H. P. Garg,et al.  System performance studies on a photovoltaic/thermal (PV/T) air heating collector , 1999 .

[28]  William Gerard Hurley,et al.  A thermal model for photovoltaic panels under varying atmospheric conditions , 2010 .

[29]  Susan Eitelman,et al.  Matlab Version 6.5 Release 13. The MathWorks, Inc., 3 Apple Hill Dr., Natick, MA 01760-2098; 508/647-7000, Fax 508/647-7001, www.mathworks.com , 2003 .