Voltage transient measurements in a distribution network and sequence of relay events associated to lightning strokes detected by LLS

A two-year experimental campaign on lightning-originated disturbances carried out in an Italian rural region characterized by a high ground flash density (4 flashes/km2/yr) has provided a set of voltage transient measurements in a medium voltage (MV) feeder that are clearly correlated with both specific events detected by the Italian lightning location system (LLS) CESI-SIRF and sequences of relay operations. The paper describes the sequence of relay events, reports the data of the correlated LLS-detected stroke and presents the corresponding voltage transients recorded at three different busses of the MV feeder.

[1]  Farhad Rachidi,et al.  Interaction of electromagnetic fields with electrical networks generated by lightning , 2003 .

[2]  Mario Paolone,et al.  A Distributed Measurement System for Correlating Faults to Lightning in Distribution Networks , 2007 .

[3]  J. G. Kappenman,et al.  High-precision location of lightning-caused distribution faults , 2001, 2001 IEEE/PES Transmission and Distribution Conference and Exposition. Developing New Perspectives (Cat. No.01CH37294).

[4]  Darveniza Mat,et al.  RESEARCH INTO LIGHTNING PROTECTION OF DISTRIBUTION SYSTEMS: II - RESULTS FROM FLORIDA FIELD WORK 1978 AND 1979. , 1983 .

[5]  D. J. Kvaltine,et al.  Lightning Faults on Distribution Lines , 1989, IEEE Power Engineering Review.

[6]  Farhad Rachidi,et al.  Correlation of Lightning Events and Faults in Distribution Power Networks: A Joint Research Project , 2008 .

[7]  D. E. Parrish Lightning-caused distribution circuit breaker operations , 1991 .

[8]  M. Paolone,et al.  A Statistical Approach for Estimating the Correlation between Lightning and Faults in Power Distribution Systems , 2006, 2006 International Conference on Probabilistic Methods Applied to Power Systems.

[9]  John G. Kappenman DISTRIBUTION LIGHTNING FAULT CORRELATION & ADVANCED APPLICATIONS OF LIGHTNING DATA , 1999 .

[10]  M. Darveniza,et al.  Research into Lightning Protection of Distribution Systems II-Results From Florida work 1978 and 1979 , 1984, IEEE Transactions on Power Apparatus and Systems.

[11]  F. Rachidi,et al.  Lightning-Correlated Faults in Power Distribution Networks , 2007, 2007 IEEE Lausanne Power Tech.

[12]  Asok K. Mukhopadhyay Measurement of lightning-induced arrester ground current in a power distribution system — Results/lessons of field study , 1979 .

[13]  Mario Paolone,et al.  Voltage Transients in a Distribution Network Correlated with Events Identified by a Lightning Location System , 2009 .