High performance ripple feedback for the buck unity-power-factor rectifier

The buck unity-power-factor rectifier has harmonic-free input current with complete load regulation down to zero output voltage. A new "nonlinear ripple feedback" is proposed which exactly cancels the spoiling effect of DC-side current ripple on the low-distortion AC line current waveforms, even for large amounts of ripple. This cancellation is independent of operating point and readily implemented with analog hardware, thereby permitting economies in the design of the DC filter while maintaining harmonic-free operation. Both large-signal and incremental analyses of the rectifier are given. Confirming experimental results from a 1 kW 48 V isolated battery charger operating with current-ripple levels ranging from 50% to discontinuous-conduction-mode operation are given. >

[1]  R. J. King Analysis and design of an unusual unity-power-factor rectifier , 1991 .

[2]  R. J. King,et al.  Ripple feedback for the resonant-filter unity-power-factor rectifier , 1992 .

[3]  R. J. King,et al.  A 1 kW unity-power-factor rectifier with isolation and fault protection , 1992, [Proceedings] APEC '92 Seventh Annual Applied Power Electronics Conference and Exposition.

[4]  Martin Schlecht,et al.  Novel topological alternatives to the design of a harmonic-free, utility/DC interface , 1983, 1983 IEEE Power Electronics Specialists Conference.