Transpiration of trees and forest stands: short and long‐term monitoring using sapflow methods

We show that sapflow is a useful tool for studies of water fluxes in forest ecosystems, because (i) it gives access to the spatial variability within a forest stand, (ii) it can be used even on steep slopes, and (iii) when combined with eddy correlation measurements over forests, it allows separation of individual tree transpiration from the total water loss of the stand. Moreover, sapflow techniques are quite easy to implement. Four sapflow techniques currently coexist, all based on heat diffusion in the xylem. We found a good agreement between three of these techniques. Most results presented here were obtained using the radial flow meter (Granier 1985). Tree sapflow is computed as sap flux density times sapwood area. To scale up from trees to a stand, measurements have to be made on a representative sample of trees. Thus, a number of trees in each circumference class is selected according to the fraction of sapwood they represent in the total sapwood area of the stand. The variability of sap flux density among trees is usually low (CV. 10–15%) in close stands of temperate coniferous or deciduous forests, but is much higher (35–50%) in a tropical rain forest. It also increases after thinning or during a dry spell. A set of 5–10 sapflow sensors usually provides an accurate estimate of stand transpiration. Transpiration measured on two dense spruce stands in the Vosges mountains (France) and one Scot's pine plantation in the Rhine valley (Germany) showed that maximum rate was related to stand LAI and to local climate. Preliminary results comparing the sapflow of a stand of Pinus banksiana to the transpiration of large branches, as part of the BOREAS programme in Saskachewan, Canada showed a similar trend. For modelling purposes, tree canopy conductance (gc) was calculated from Penman-Monteith equation. In most experiments, calculated canopy conductance was dependent on global radiation (positive effect) and on vapour pressure deficit (negative effect) in the absence of other limiting factors. A comparison of the vapour pressure deficit response curves of gc for several tree species and sites showed only small differences among spruce, oak and pine forests when including understorey. Tropical rainforests exhibited a similar behaviour.

[1]  N. Breda,et al.  Water relations of adult Norway spruce (Picea abies (L.) Karst) under soil drought in the Vosges mountains : water potential, stomatal conductance and transpiration , 1995 .

[2]  Y. Kiyono,et al.  Transpiration of a 31-year-old Chamaecyparis obtusa Endl. stand before and after thinning. , 1986, Tree physiology.

[3]  Denis Loustau,et al.  Measuring and modelling the transpiration of a maritime pine canopy from sap-flow data , 1994 .

[4]  G. Goldstein,et al.  Stomatal and environmental control of transpiration in a lowland tropical forest tree , 1993 .

[5]  R. H. Swanson,et al.  A Numerical Analysis of Heat Pulse Velocity Theory and Practice , 1981 .

[6]  A. Granier Une nouvelle méthode pour la mesure du flux de sève brute dans le tronc des arbres , 1985 .

[7]  Tetsuo Sakuratani,et al.  A heat balance method for measuring water flux in the stem of intact plants , 1981 .

[8]  E. Dufrene,et al.  A branch bag technique for simultaneous CO2 enrichment and assimilation measurements on beech (Fagus sylvatica L.) , 1993 .

[9]  C. R. Lloyd,et al.  Micrometeorological measurements in Les Landes forest during HAPEX-MOBILHY , 1989 .

[10]  N. Breda,et al.  Effects of thinning on soil and tree water relations, transpiration and growth in an oak forest (Quercus petraea (Matt.) Liebl.). , 1995, Tree physiology.

[11]  R. Huc,et al.  Transpiration of natural rain forest and its dependence on climatic factors , 1996 .

[12]  K. G. McNaughton,et al.  Stomatal Control of Transpiration: Scaling Up from Leaf to Region , 1986 .

[13]  W. J. Shuttleworth,et al.  Micrometeorology of Temperate and Tropical Forest , 1989 .

[14]  C. Valancogne,et al.  Water Transport in Plants under Climatic Stress: A heat balance method for measuring sap flow in small trees , 1993 .

[15]  R. Valentini,et al.  Axial and radial water flow in the trunks of oak trees: a quantitative and qualitative analysis. , 1994, Tree physiology.

[16]  L. Gay,et al.  Tests of a robust eddy correlation system for sensible heat flux , 1992 .

[17]  F. Meinzer,et al.  Stomatal control of transpiration. , 1993, Trends in ecology & evolution.

[18]  N. Breda,et al.  Water transfer in a mature oak stand (Quercus petraea) : Seasonal evolution and effects of a severe drought , 1993 .

[19]  John H. C. Gash,et al.  Vapour flux density and transpiration rate comparisons in a stand of Maritime pine (Pinus pinaster Ait.) in Les Landes forest , 1990 .

[20]  A. Granier,et al.  Mesure du flux de sève brute dans le tronc du Douglas par une nouvelle méthode thermique , 1987 .

[21]  Richard H. Waring,et al.  Sapwood water storage: its contribution to transpiration and effect upon water conductance through the stems of old‐growth Douglas‐fir , 1978 .

[22]  A. Granier,et al.  Evaluation of transpiration in a Douglas-fir stand by means of sap flow measurements. , 1987, Tree physiology.