Design-oriented stress–strain model for concrete prisms confined with FRP composites

Abstract A good modeling of the stress–strain behavior of FRP-confined concrete prism is necessary for the design of rectangular columns retrofitted with FRP composites. Existing stress–strain models for FRP-confined concrete prisms are mostly presented based on the concept of steel-confined concrete columns. Based on the results of more than one hundred specimens, the mechanical behavior of FRP-confined concrete prisms are studied in this paper. It is found that the stress–strain relationship of FRP-confined prism has either a strain-hardening or a strain-softening response, which mainly depends on the confinement strength of FRP, corner radius of cross-section, etc. Equations to predict the transitional stress and strain of FRP-confined concrete prisms are presented. By reducing the corresponding ultimate strength and strain of equivalent concrete cylinders confined with equivalent FRP, the ultimate strength and strain of FRP-confined concrete prisms can be predicted rationally. Three design-oriented models, which can be applied to various conditions, are suggested. The feature of those models is simple, and they agree well with extensive experimental results.

[1]  H. Toutanji STRESS-STRAIN CHARACTERISTICS OF CONCRETE COLUMNS EXTERNALLY CONFINED WITH ADVANCED FIBER COMPOSITE SHEETS , 1999 .

[2]  Robert Park,et al.  DUCTILITY OF REINFORCED CONCRETE COLUMN SECTIONS IN SEISMIC DESIGN , 1972 .

[3]  Kiang Hwee Tan,et al.  Strength Enhancement of Rectangular Reinforced Concrete Columns using Fiber-Reinforced Polymer , 2002 .

[4]  Wei Wang,et al.  Behavior of FRP Jacketed Concrete Columns under Eccentric Loading , 2001 .

[5]  M. Maalej,et al.  Modelling of rectangular RC columns strengthened with FRP , 2003 .

[6]  Jin-Guang Teng,et al.  A NEW STRESS-STRAIN MODEL FOR FRP-CONFINED CONCRETE , 2001 .

[7]  Amir Mirmiran,et al.  Model of Concrete Confined by Fiber Composites , 1998 .

[8]  Zhishen Wu,et al.  STRESS-STRAIN RELATIONSHIP FOR FRP-CONFINED CONCRETE CYLINDERS , 2003 .

[9]  Murat Saatcioglu,et al.  Strength and Ductility of Confined Concrete , 1992 .

[10]  Richard Sause,et al.  AXIAL BEHAVIOR OF REINFORCED CONCRETE COLUMNS RETROFIT WITH FRPC JACKETS , 1998 .

[11]  A. Mirmiran,et al.  Effect of Column Parameters on FRP-Confined Concrete , 1998 .

[12]  Hamid Saadatmanesh,et al.  STRENGTH AND DUCTILITY OF CONCRETE COLUMNS EXTERNALLY REINFORCED WITH FIBER COMPOSITE STRAPS , 1994 .

[13]  Pierre Labossière,et al.  Axial Testing of Rectangular Column Models Confined with Composites , 2000 .

[14]  J. Mander,et al.  Theoretical stress strain model for confined concrete , 1988 .

[15]  Zhishen Wu,et al.  Strength and ductility of concrete cylinders confined with FRP composites , 2006 .