Quantitative PET image reconstruction employing nested expectation-maximization deconvolution for motion compensation

Bulk body motion may randomly occur during PET acquisitions introducing blurring, attenuation-emission mismatches and, in dynamic PET, discontinuities in the measured time activity curves between consecutive frames. Meanwhile, dynamic PET scans are longer, thus increasing the probability of bulk motion. In this study, we propose a streamlined 3D PET motion-compensated image reconstruction (3D-MCIR) framework, capable of robustly deconvolving intra-frame motion from a static or dynamic 3D sinogram. The presented 3D-MCIR methods need not partition the data into multiple gates, such as 4D MCIR algorithms, or access list-mode (LM) data, such as LM MCIR methods, both associated with increased computation or memory resources. The proposed algorithms can support compensation for any periodic and non-periodic motion, such as cardio-respiratory or bulk motion, the latter including rolling, twisting or drifting. Inspired from the widely adopted point-spread function (PSF) deconvolution 3D PET reconstruction techniques, here we introduce an image-based 3D generalized motion deconvolution method within the standard 3D maximum-likelihood expectation-maximization (ML-EM) reconstruction framework. In particular, we initially integrate a motion blurring kernel, accounting for every tracked motion within a frame, as an additional MLEM modeling component in the image space (integrated 3D-MCIR). Subsequently, we replaced the integrated model component with a nested iterative Richardson-Lucy (RL) image-based deconvolution method to accelerate the MLEM algorithm convergence rate (RL-3D-MCIR). The final method was evaluated with realistic simulations of whole-body dynamic PET data employing the XCAT phantom and real human bulk motion profiles, the latter estimated from volunteer dynamic MRI scans. In addition, metabolic uptake rate Ki parametric images were generated with the standard Patlak method. Our results demonstrate significant improvement in contrast-to-noise ratio (CNR) and noise-bias performance in both dynamic and parametric images. The proposed nested RL-3D-MCIR method is implemented on the Software for Tomographic Image Reconstruction (STIR) open-source platform and is scheduled for public release.

[1]  Habib Zaidi,et al.  Whole-body direct 4D parametric PET imaging employing nested generalized Patlak expectation–maximization reconstruction , 2016, Physics in medicine and biology.

[2]  Paul E Kinahan,et al.  The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging , 2009, Physics in medicine and biology.

[3]  Martin A Lodge,et al.  Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application , 2013, Physics in medicine and biology.

[4]  Tobias Schaeffter,et al.  Hierarchical adaptive local affine registration for fast and robust respiratory motion estimation , 2011, Medical Image Anal..

[5]  Xiaoyi Jiang,et al.  Motion Correction in Dual Gated Cardiac PET Using Mass-Preserving Image Registration , 2012, IEEE Transactions on Medical Imaging.

[6]  Joseph O Deasy,et al.  Deblurring of breathing motion artifacts in thoracic PET images by deconvolution methods. , 2006, Medical physics.

[7]  M. Ozaki,et al.  Evaluation of liver tumors using fluorine-18-fluorodeoxyglucose PET: characterization of tumor and assessment of effect of treatment. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  N. Schwenzer,et al.  Respiratory Motion Correction in Oncologic PET Using T1-Weighted MR Imaging on a Simultaneous Whole-Body PET/MR System , 2013, The Journal of Nuclear Medicine.

[9]  Ravindra Manjeshwar,et al.  Theoretical Comparison of Motion Correction Techniques for PET Image Reconstruction , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[10]  John W. Clark,et al.  A motion-incorporated reconstruction method for gated PET studies , 2006, Physics in medicine and biology.

[11]  Kehong Yuan,et al.  Respiratory motion blur identification and reduction in ungated thoracic PET imaging , 2011, Physics in medicine and biology.

[12]  Doumit Daou,et al.  Respiratory motion handling is mandatory to accomplish the high-resolution PET destiny , 2008, European Journal of Nuclear Medicine and Molecular Imaging.

[13]  David Atkinson,et al.  Practical PET Respiratory Motion Correction in Clinical PET/MR , 2015, The Journal of Nuclear Medicine.

[14]  Tobias Schaeffter,et al.  Simultaneous PET–MR acquisition and MR-derived motion fields for correction of non-rigid motion in PET , 2010, Annals of nuclear medicine.

[15]  Arman Rahmim,et al.  Intra-frame Motion Compensation in Multi-frame Brain PET Imaging , 2015 .

[16]  D. Feng,et al.  Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography. , 1993, International journal of bio-medical computing.

[17]  C. J. Thompson,et al.  Motion correction of PET images using multiple acquisition frames , 1997, IEEE Transactions on Medical Imaging.

[18]  Habib Zaidi,et al.  Four-Dimensional Image Reconstruction Strategies in Cardiac-Gated and Respiratory-Gated PET Imaging. , 2013, PET clinics.

[19]  Arman Rahmim,et al.  Resolution modeling in PET imaging: Theory, practice, benefits, and pitfalls. , 2013, Medical physics.

[20]  Xiaoyi Jiang,et al.  Respiratory Motion Correction in 3-D PET Data With Advanced Optical Flow Algorithms , 2008, IEEE Transactions on Medical Imaging.

[21]  Joyoni Dey,et al.  Digital anthropomorphic phantoms of non-rigid human respiratory and voluntary body motion for investigating motion correction in emission imaging , 2014, Physics in medicine and biology.

[22]  Qinan Bao,et al.  Investigation of the minimum detectable activity level of a preclinical LSO PET scanner , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[23]  Michael E Casey,et al.  Motion Correction Strategies for Integrated PET/MR , 2015, The Journal of Nuclear Medicine.

[24]  Ciprian Catana,et al.  MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI , 2012, The Journal of Nuclear Medicine.

[25]  Rafael C. González,et al.  Local Determination of a Moving Contrast Edge , 1985, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[26]  Arman Rahmim,et al.  Whole-body PET parametric imaging employing direct 4D nested reconstruction and a generalized non-linear Patlak model , 2014, Medical Imaging.

[27]  Quanzheng Li,et al.  Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study , 2013, Physics in medicine and biology.

[28]  Guobao Wang,et al.  Acceleration of the direct reconstruction of linear parametric images using nested algorithms , 2010, Physics in medicine and biology.

[29]  N Raghunath,et al.  Motion correction of PET brain images through deconvolution: I. Theoretical development and analysis in software simulations , 2009, Physics in medicine and biology.

[30]  Habib Zaidi,et al.  Novel multi-parametric SUV/Patlak FDG-PET whole-body imaging framework for routine application to clinical oncology , 2015 .

[31]  F A Kotasidis,et al.  Acceleration of image-based resolution modelling reconstruction using an expectation maximization nested algorithm , 2013, Physics in medicine and biology.

[32]  Xiaoyi Jiang,et al.  Lung motion correction on respiratory gated 3-D PET/CT images , 2006, IEEE Transactions on Medical Imaging.

[33]  N Raghunath,et al.  Motion correction of PET brain images through deconvolution: II. Practical implementation and algorithm optimization , 2009, Physics in medicine and biology.

[34]  Roger Fulton,et al.  The design and implementation of a motion correction scheme for neurological PET. , 2003, Physics in medicine and biology.

[35]  C. Tsoumpas,et al.  STIR: software for tomographic image reconstruction release 2 , 2012, 2006 IEEE Nuclear Science Symposium Conference Record.

[36]  Y Yonekura,et al.  In vivo assessment of glucose metabolism in hepatocellular carcinoma with FDG-PET. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[37]  Dean F. Wong,et al.  Accurate Event-Driven Motion Compensation in High-Resolution PET Incorporating Scattered and Random Events , 2008, IEEE Transactions on Medical Imaging.

[38]  W. Segars,et al.  4D XCAT phantom for multimodality imaging research. , 2010, Medical physics.

[39]  P.M. Bloomfield,et al.  Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET , 2005, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[40]  Ross Berbeco,et al.  Evaluation of the combined effects of target size, respiratory motion and background activity on 3D and 4D PET/CT images , 2008, Physics in medicine and biology.

[41]  Habib Zaidi,et al.  Impact of acquisition time-window on clinical whole-body PET parametric imaging , 2014, 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).

[42]  Martin A Lodge,et al.  Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation , 2013, Physics in medicine and biology.

[43]  D. Hunter,et al.  Optimization Transfer Using Surrogate Objective Functions , 2000 .

[44]  Tobias Schaeffter,et al.  A 3D MR-acquisition scheme for nonrigid bulk motion correction in simultaneous PET-MR. , 2014, Medical physics.

[45]  A. Rahmim,et al.  Motion compensation in histogram-mode and list-mode EM reconstructions: beyond the event-driven approach , 2004, IEEE Transactions on Nuclear Science.

[46]  D. Townsend,et al.  Physical and clinical performance of the mCT time-of-flight PET/CT scanner , 2011, Physics in medicine and biology.

[47]  Habib Zaidi,et al.  Generalized 3D and 4D motion compensated whole-body PET image reconstruction employing nested EM deconvolution , 2014, 2014 IEEE International Conference on Imaging Systems and Techniques (IST) Proceedings.

[48]  Ciprian Catana,et al.  Simultaneous PET-MRI: a new approach for functional and morphological imaging , 2008, Nature Medicine.

[49]  Habib Zaidi,et al.  Generalized whole-body Patlak parametric imaging for enhanced quantification in clinical PET , 2015, Physics in medicine and biology.

[50]  C Tsoumpas,et al.  Analysis and comparison of two methods for motion correction in PET imaging. , 2012, Medical physics.

[51]  Guobao Wang,et al.  An Optimization Transfer Algorithm for Nonlinear Parametric Image Reconstruction From Dynamic PET Data , 2012, IEEE Transactions on Medical Imaging.

[52]  Habib Zaidi,et al.  Strategies for Motion Tracking and Correction in PET. , 2007, PET clinics.

[53]  Uwe Haberkorn,et al.  Quantitative assessment of SSTR2 expression in patients with non-small cell lung cancer using68Ga-DOTATOC PET and comparison with18F-FDG PET , 2006, European Journal of Nuclear Medicine and Molecular Imaging.

[54]  Ludwig G Strauss,et al.  Quantitative, dynamic 18F-FDG-PET for the evaluation of soft tissue sarcomas: relation to differential diagnosis, tumor grading and prediction of prognosis. , 2009, Hellenic journal of nuclear medicine.

[55]  A J Reader,et al.  List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations , 2007, Physics in medicine and biology.

[56]  Hiroyuki Okada,et al.  Short dynamic FDG-PET imaging protocol for patients with lung cancer , 2000, European Journal of Nuclear Medicine.